Sonosite Maxx Series Diagnostic Ultrasound System

K071134510(k) TraditionalCleared May 8, 200715-day reviewClass II21 CFR 892.1560Recalls 2

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Sonosite,Inc. · IYO System, Imaging, Pulsed Echo, Ultrasonic

Cleared on May 8, 2007 as substantially equivalent to K043559 (Sonosite,Inc., 2005) and 3 other predicates after a 15-day review. Its family tree reaches back 5 generations to 1995. 259 later devices descend from it. It has been recalled 2 times.

Decided
May 8, 2007
Review
15 days
Class
Class II
Product code
IYO
Recalls
2
Predicates
4

Its longest line of descent runs back 5 generations to K945773 (1995). 16 ancestors in all. 259 later devices descend from it, 6 citing it directly.

Other ancestors, by year clearedDescendants, by year cleared 2004: 1 other ancestor2001: 2 other ancestors2002: 1 other ancestor2000: 3 other ancestors1999: 1 other ancestor1997: 2 other ancestors1995: 1 other ancestor2008: 1 descendant cleared2010: 3 descendants cleared2009: 1 descendant cleared2011: 3 descendants cleared2015: 12 descendants cleared2013: 7 descendants cleared2012: 3 descendants cleared2016: 16 descendants cleared2014: 5 descendants cleared2020: 28 descendants cleared2017: 19 descendants cleared2018: 19 descendants cleared2019: 21 descendants cleared2023: 17 descendants cleared2022: 28 descendants cleared2025: 20 descendants cleared2021: 21 descendants cleared2026: 16 descendants cleared2024: 19 descendants clearedReference device: K030949 · Titan High Resolution Ultrasound System · Sonosite,Inc. · 2003Reference device: K033367 · Titan Ultrasound System, Sonosite Ilook 25 Ultrasound System, 180PLUS Ultrasound System, Model L03073, L02245, L02464 · Sonosite,Inc. · 2003K945773 · Siemens Sonoline Versa · Siemens Medical Solutions USA, Inc. · 1995K020353 · Omnia X/XS Ultrasound System · Siemens Medical Systems, Inc. · 2002K030949 · Titan High Resolution Ultrasound System · Sonosite,Inc. · 2003K043559 · Sonosite High-Resolution Diagnostic Ultrasound System (C3 Series) · Sonosite,Inc. · 2005 · recalledK053069 · Sonosite Micromaxx Diagnostic Ultrasound System (C3 Series) · Sonosite,Inc. · 2005 · recalled1995200020052010201520202025
Other ancestors, by generationDescendants, by generation 1 generation back: 2 other ancestors2 generations back: 7 other ancestors3 generations back: 2 other ancestors 1 generation forward: 6 descendants2 generations forward: 11 descendants3 generations forward: 28 descendants4 generations forward: 34 descendants5 generations forward: 30 descendants6 generations forward: 39 descendants7 generations forward: 35 descendants8 generations forward: 24 descendants9 generations forward: 20 descendants10 generations forward: 11 descendants11 generations forward: 7 descendants12 generations forward: 5 descendants13 generations forward: 4 descendants14 generations forward: 4 descendants15 generations forward: 1 descendant K053069 · Sonosite Micromaxx Diagnostic Ultrasound System (C3 Series) · Sonosite,Inc. · 2005 · recalledK043559 · Sonosite High-Resolution Diagnostic Ultrasound System (C3 Series) · Sonosite,Inc. · 2005 · recalledK030949 · Titan High Resolution Ultrasound System · Sonosite,Inc. · 2003K020353 · Omnia X/XS Ultrasound System · Siemens Medical Systems, Inc. · 2002K945773 · Siemens Sonoline Versa · Siemens Medical Solutions USA, Inc. · 1995−50+5+10+15
  1. Root · 5 generations backK945773 Siemens Sonoline VersaSiemens Medical Solutions USA, Inc. · 1995
  2. 4 generations backK020353 Omnia X/XS Ultrasound SystemSiemens Medical Systems, Inc. · 2002
  3. 3 generations backK030949 Titan High Resolution Ultrasound SystemSonosite,Inc. · 2003
  4. 2 generations backK043559 Sonosite High-Resolution Diagnostic Ultrasound System (C3 Series)Sonosite,Inc. · 2005 · Recalled
  5. 1 generation backK053069 Sonosite Micromaxx Diagnostic Ultrasound System (C3 Series)Sonosite,Inc. · 2005 · Recalled
  6. This deviceK071134 Sonosite Maxx Series Diagnostic Ultrasound SystemSonosite,Inc. · 2007
  7. Descendant · cites it directly · 247 of its ownK082098 Sonosite Maxx Series Ultrasound SystemSonosite,Inc. · 2008 · Recalled
  8. Descendant · cites it directly · 216 of its ownK113156 Sonosite Edge Ultrasound SystemSonosite,Inc. · 2011 · Recalled
  9. Descendant · 2 generations on · 149 of its ownK133533 Logiq EGE Healthcare · 2014
  10. Descendant · 3 generations on · 131 of its ownK143452 Logiq P9, Logiq P7GE Healthcare · 2015
  11. Descendant · 4 generations on · 107 of its ownK161047 LOGIQ P9 and LOGIQ P7GE Healthcare · 2016

Showing 5 of 259 descendants. See all descendants

Descendants cleared per year

2008: 12009: 12010: 32011: 32012: 32013: 72014: 52015: 122016: 162017: 192018: 192019: 212020: 282021: 212022: 282023: 172024: 192025: 202026: 16
2008high 28 (2020) · low 1 (2008)2026

Most influential descendants

Showing 5 of 259 · See all
  • K082098Sonosite Maxx Series Ultrasound SystemSonosite,Inc. · 2008 · cites it directly247descendants
  • K113156Sonosite Edge Ultrasound SystemSonosite,Inc. · 2011 · cites it directly216descendants
  • K133533Logiq EGE Healthcare · 2014 · 2 generations on149descendants
  • K143452Logiq P9, Logiq P7GE Healthcare · 2015 · 3 generations on131descendants
  • K161047LOGIQ P9 and LOGIQ P7GE Healthcare · 2016 · 4 generations on107descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−5K945773Siemens Sonoline VersaSiemens Medical Solutions USA, Inc.1995—
−4K020353Omnia X/XS Ultrasound SystemSiemens Medical Systems, Inc.2002—
−3K030949Titan High Resolution Ultrasound SystemSonosite,Inc.2003—
−2K043559Sonosite High-Resolution Diagnostic Ultrasound System (C3 Series)Sonosite,Inc.20054
−1K053069Sonosite Micromaxx Diagnostic Ultrasound System (C3 Series)Sonosite,Inc.20053
0 (this device)K071134Sonosite Maxx Series Diagnostic Ultrasound SystemSonosite,Inc.2007—
+1K082098Sonosite Maxx Series Ultrasound SystemSonosite,Inc.20082
+1K113156Sonosite Edge Ultrasound SystemSonosite,Inc.20111
+2K133533Logiq EGE Healthcare2014—
+3K143452Logiq P9, Logiq P7GE Healthcare2015—
+4K161047LOGIQ P9 and LOGIQ P7GE Healthcare2016—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199510
199720
199910
200030
200120
200210
200410

Descendants by year cleared

Year clearedDevicesWith a Class I recall
200810
200910
201030
201130
201230
201370
201450
2015120
2016160
2017190
2018190
2019210
2020280
2021210
2022280
2023170
2024190
2025200
2026160
FIG. 1 — Lineage of K071134, 1995–2026Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in IYO? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new IYO device

  1. #1 K243937 Accuro 3Sscore 20.5 · 18 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (4)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K043559Sonosite High-Resolution Diagnostic Ultrasound System (C3 Series)
Summary page 12
…n the placement of needles and catheters in vascular or other anatomical structures was cleared in K030949. All items marked P were previously cleared in510(k) K043559. Prescription Use (Per 21 CFR 801.109) (Division~ Si n-Oft~…
Sonosite,Inc.20054
*K053069Sonosite Micromaxx Diagnostic Ultrasound System (C3 Series)
Summary page 1
…lieves that the System described in this Submission is substantially equivalent to a combination of the SonoSite MicroMaxx Series Ultrasound System jK43559 and K053069), and the Philips Medical Systems (formerly Advanced Technology Laboratories) HDI 5000 Ultrasound System (K034003 and…
Sonosite,Inc.20053
*K034003Hdi 5000 Diagnostic Ultrasound System
Summary page 1
…icroMaxx Series Ultrasound System jK43559 and K053069), and the Philips Medical Systems (formerly Advanced Technology Laboratories) HDI 5000 Ultrasound System (K034003 and K01 1224). 510O(K) Summary Of Safety And Effectiveness…
Philips Ultrasound, Inc.20044
*K011224Hdi 5000 Ultrasound System with Assisted Border Detection (Abd), Xres Imaging, and…
Summary page 1
…ound System jK43559 and K053069), and the Philips Medical Systems (formerly Advanced Technology Laboratories) HDI 5000 Ultrasound System (K034003 and K01 1224). 510O(K) Summary Of Safety And Effectiveness Page I Of 6…
Advanced Technology Laboratories, Inc.2001—
†K030949Titan High Resolution Ultrasound SystemSonosite,Inc.2003—
†K033367Titan Ultrasound System, Sonosite Ilook 25 Ultrasound System, 180PLUS Ultrasound System…Sonosite,Inc.2003—

Also cleared against K043559: 4 other devices →

What descends from it? (259)

See all 259

6 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K082098Sonosite Maxx Series Ultrasound SystemSonosite,Inc.2008247
K113156Sonosite Edge Ultrasound SystemSonosite,Inc.2011216
K092058Sonosite Nanomaxx Series Ultrasound SystemSonosite,Inc.200927
K100402Site-Rite Vision Ultrasound SystemBard Access Systems, Inc.201010
K150148Terason uSmart3300 Ultrasound SystemTeratech Corp.20150
K102390Sonosite Nanomaxx Series Ultrasound SystemSonosite,Inc.20100

Has anything in its family been recalled? (0 Class I)

Recalls of this device

DateClassRecallRoot causeReason
Jul 18, 2011Not classifiedZ-0057-2012Software designThis is a software anomaly. In some circumstances, if the Systolic/Diastolic (S/D) ratio value is interpreted directly from the display, the clinician could potentially use an incorrect value of the S/D ratio in his/her assessment.
Aug 8, 2008Not classifiedZ-2191-2010OtherThe TEE transesophageal transducer, when connected to a SonoSite M-Turbo Ultrasound System, may exhibit erratic operation of the Scanplane Orientation Indicator on the system display. The indicator may move erratically and not accurately…

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 12 years and passes through 3 companies; a new generation was cleared every 1.5 years on median.
  • 5 of the 16 ancestors have a recall of any class.
  • Of its descendants, K082098 (Sonosite,Inc., 2008) has gone furthest, with 247 descendants of its own.
  • 4 other devices also cite its predicate K043559.

How does its category compare?

All IYO devices

IYO System, Imaging, Pulsed Echo, Ultrasonic: FDA decisions, review times, recalls and adverse event reports over 20 years. 2007, this device’s year, is highlighted.

FDA decisions per year · IYO

7in 2025

2007: 202008: 142009: 132010: 152011: 112012: 152013: 172014: 142015: 192016: 102017: 192018: 142019: 132020: 112021: 152022: 52023: 112024: 102025: 72026 (partial year): 10
2007high 20 (2007) · low 5 (2022)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · IYO

171in 2025

2007: 17 days median2008: 36 days median2009: 79 days median2010: 113 days median2011: 69 days median2012: 68 days median2013: 50 days median2014: 63 days median2015: 46 days median2016: 36 days median2017: 72 days median2018: 56 days median2019: 59 days median2020: 57 days median2021: 64 days median2022: 190 days median2023: 177 days median2024: 220 days median2025: 171 days median2026 (partial year): 139 days median
2007high 220 (2024) · low 17 (2007)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · IYO

1in 2022

2007: 42008: 52009: 92010: 82012: 22013: 32014: 22015: 12018: 12019: 12021: 112022: 12026 (partial year): 1
2007high 11 (2021) · low 0 (2011)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · IYO

485in 2025

2007: 392008: 202009: 272010: 202011: 582012: 782013: 4362014: 3042015: 2682016: 2542017: 2382018: 3682019: 5372020: 4982021: 6172022: 5112023: 5272024: 6402025: 485
2007high 640 (2024) · low 20 (2008)2025

MAUDE reports naming product code IYO, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20072017439
20081436520
20091379927
201015113820
20111169058
20121568278
201317503436
201414632304
201519461268
201610360254
201719720238
201814561368
201913591537
202011570498
2021156411617
202251901511
2023111770527
2024102200640
202571710485
2026101391—

What is it indicated for?

Diagnostic ultrasound imaging or fluid flow analysis of the human body as follows:

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K071134: Sonosite Maxx Series Diagnostic Ultrasound System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K071134

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026