510(k) Report

510(k) · Cleared

Cleared

Diacap LO PS (10, 12, 15) and Diacap HI PS (10, 12, 15, 18, 20) Hemodialyzers

K071518510(k) TraditionalCleared Aug 17, 200774-day reviewClass II21 CFR 876.5860

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

B. Braun Medizintechnologie GmbH · KDI Dialyzer, High Permeability With Or Without Sealed Dialysate System

Cleared on Aug 17, 2007 after a 74-day review. The FDA summary names its predicate without a number. 3 later devices descend from it.

Decided
Aug 17, 2007
Review
74 days
Class
Class II
Product code
KDI
Recalls
None
Predicates
0

3 later devices descend from it, 3 citing it directly.

Descendants, by year cleared 2017: 1 descendant cleared2016: 1 descendant cleared2010: 1 descendant cleared20052010201520202025
  1. This deviceK071518 Diacap LO PS (10, 12, 15) and Diacap HI PS (10, 12, 15, 18, 20)…B. Braun Medizintechnologie GmbH · 2007
  2. Descendant · cites it directly · 1 of its ownK100334 Diacap Polysulfone Hiflo 23 Hemodilayzer , Model 72036811B. Braun Avitum AG · 2010
  3. Descendant · cites it directly · 0 of its ownK170574 Diacap Pro DialyzerB. Braun Avitum AG · 2017
  4. Descendant · cites it directly · 0 of its ownK143482 xevonta dialyzerB. Braun Avitum AG · 2016

Most influential descendants

Showing 3 of 3 · See all
  • K100334Diacap Polysulfone Hiflo 23 Hemodilayzer , Model 72036811B. Braun Avitum AG · 2010 · cites it directly1descendant
  • K170574Diacap Pro DialyzerB. Braun Avitum AG · 2017 · cites it directly0descendants
  • K143482xevonta dialyzerB. Braun Avitum AG · 2016 · cites it directly0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
0 (this device)K071518Diacap LO PS (10, 12, 15) and Diacap HI PS (10, 12, 15, 18, 20) HemodialyzersB. Braun Medizintechnologie GmbH2007—
+1K100334Diacap Polysulfone Hiflo 23 Hemodilayzer , Model 72036811B. Braun Avitum AG2010—
+1K170574Diacap Pro DialyzerB. Braun Avitum AG2017—
+1K143482xevonta dialyzerB. Braun Avitum AG2016—

Descendants by year cleared

Year clearedDevicesWith a Class I recall
201010
201610
201710
FIG. 1 — Lineage of K071518, 2007–2017Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in KDI? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new KDI device

  1. #1 K243874 FX CorAL 60 (F00012969); FX CorAL 80…score 18.2 · 12 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (13)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*—Hemoflow F5
Named without a submission number
—
*—Hemoflow F6
Named without a submission number
—
*—Hemoflow F7
Named without a submission number
—
*—Hemoflow F8
Named without a submission number
—
*—Hemoflow F 50 NR
Named without a submission number
—
*—Hemoflow F 60 A
Named without a submission number
—
*—Hemoflow F 60 B
Named without a submission number
—
*—Hemoflow F 70 A
Named without a submission number
—
*—Hemoflow F 70 B
Named without a submission number
—
*—Hemoflow F 70 NR
Named without a submission number
—
*—Hemoflow F 80 A
Named without a submission number
—
*—Hemoflow F 80 B
Named without a submission number
—
*—Optiflux 200 A
Named without a submission number
—

What descends from it? (3)

3 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K100334Diacap Polysulfone Hiflo 23 Hemodilayzer , Model 72036811B. Braun Avitum AG20101
K170574Diacap Pro DialyzerB. Braun Avitum AG20170
K143482xevonta dialyzerB. Braun Avitum AG20160

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • Of its descendants, K100334 (B. Braun Avitum AG, 2010) has gone furthest, with 1 descendant of its own.

How does its category compare?

All KDI devices

KDI Dialyzer, High Permeability With Or Without Sealed Dialysate System: FDA decisions, review times, recalls and adverse event reports over 20 years. 2007, this device’s year, is highlighted.

FDA decisions per year · KDI

9in 2025

2007: 112008: 62009: 42010: 92011: 52012: 62013: 112014: 82015: 52016: 52017: 82018: 22019: 42020: 92021: 22022: 72023: 72024: 72025: 92026 (partial year): 6
2007high 11 (2007) · low 2 (2018)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · KDI

199in 2025

2007: 91 days median2008: 148 days median2009: 236 days median2010: 186 days median2011: 85 days median2012: 153 days median2013: 247 days median2014: 164 days median2015: 69 days median2016: 230 days median2017: 188 days median2019: 263 days median2020: 266 days median2022: 259 days median2023: 157 days median2024: 235 days median2025: 199 days median2026 (partial year): 154 days median
2007high 266 (2020) · low 69 (2015)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · KDI

2in 2025

2007: 42009: 32010: 12011: 42012: 12013: 22014: 32015: 52016: 42017: 12018: 12019: 62021: 22022: 172023: 8, 8 Class I2024: 4, 2 Class I2025: 22026 (partial year): 2
2007high 17 (2022) · low 0 (2008)2026

Class I (10 since 2007) Class II/III not classified

Adverse event reports per year · KDI

2,786in 2025

2007: 9162008: 1,0422009: 5222010: 8232011: 2,2702012: 1,7652013: 2,3602014: 6,1542015: 4,1822016: 7662017: 9632018: 1,7162019: 1,5872020: 1,6332021: 1,9442022: 2,1802023: 2,6922024: 2,4412025: 2,786
2007high 6,154 (2014) · low 522 (2009)2025

MAUDE reports naming product code KDI, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
200711914916
2008614801,042
200942363522
201091861823
201158542,270
2012615311,765
20131124722,360
2014816436,154
201556954,182
201652304766
201781881963
20182—11,716
2019426361,587
2020926601,633
20212—21,944
20227259172,180
202371578 (8)2,692
202472354 (2)2,441
2025919922,786
202661542—

What is it indicated for?

Diacap LOPS (10, 12, 15) and Diacap HI PS (10, 12, 15, 18, 20) Hemodialyzers are designed for single use in acute and chronic hemodialysis.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K071518: Diacap LO PS (10, 12, 15) and Diacap HI PS (10, 12, 15, 18, 20) Hemodialyzers.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 5, 2026. https://510kreport.com/device/K071518

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026