510(k) Report

510(k) · Cleared

Cleared

Kensey Nash Macropore Shield

K071695510(k) TraditionalCleared Dec 31, 2007194-day reviewClass II21 CFR 878.3300

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Kensey Nash Corp. · FTL Mesh, Surgical, Polymeric

Cleared on Dec 31, 2007 as substantially equivalent to K012025 (Macropore Biosurgery, Inc., 2001) and 1 other predicate after a 194-day review. Its family tree reaches back 2 generations to 2001.

Decided
Dec 31, 2007
Review
194 days
Class
Class II
Product code
FTL
Recalls
None
Predicates
2

Its longest line of descent runs back 2 generations to K002699 (2001). 3 ancestors in all. No later device cites it as a predicate yet.

Other ancestors, by year cleared 2001: 1 other ancestorK002699 · Parietex Composite (Pco) Mesh · Medical Device Consultants, Inc. · 2001K031955 · Macropore Surgi-Wrap Mast Bioresorbable Sheet · Macropore Biosurgery, Inc. · 200320002002200420062008
  1. Root · 2 generations backK002699 Parietex Composite (Pco) MeshMedical Device Consultants, Inc. · 2001
  2. 1 generation backK031955 Macropore Surgi-Wrap Mast Bioresorbable SheetMacropore Biosurgery, Inc. · 2003
  3. This deviceK071695 Kensey Nash Macropore ShieldKensey Nash Corp. · 2007
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−2K002699Parietex Composite (Pco) MeshMedical Device Consultants, Inc.2001—
−1K031955Macropore Surgi-Wrap Mast Bioresorbable SheetMacropore Biosurgery, Inc.2003—
0 (this device)K071695Kensey Nash Macropore ShieldKensey Nash Corp.2007—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
200110
FIG. 1 — Lineage of K071695, 2001–2007Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in FTL? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new FTL device

  1. #1 K220091 Poly-Tape/Infinity-Lock Soft Tissue…score 16.8 · 14 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (2)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K012025Macropore Surgiwrap (TS)
Summary page 2
…e-amendment devices: MacroPore Surgi-Wrap (TS) and the MacroPore Surgi-Wrap MAST; Class II medical devices that were cleared for marketing in the United States under K012025 and K031955, respectively. Indications For Use The Kensey Nash Bioresorbable Surgical Mesh shares identical indicati…
Macropore Biosurgery, Inc.2001—
*K031955Macropore Surgi-Wrap Mast Bioresorbable Sheet
Summary page 2
…ces: MacroPore Surgi-Wrap (TS) and the MacroPore Surgi-Wrap MAST; Class II medical devices that were cleared for marketing in the United States under K012025 and K031955, respectively. Indications For Use The Kensey Nash Bioresorbable Surgical Mesh shares identical indications for use prin…
Macropore Biosurgery, Inc.2003—

Also cleared against K012025: 4 other devices →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 6 years and passes through 3 companies; a new generation was cleared every 4.3 years on median.
  • None of the 3 ancestors has a recall.
  • 4 other devices also cite its predicate K012025.

How does its category compare?

All FTL devices

FTL Mesh, Surgical, Polymeric: FDA decisions, review times, recalls and adverse event reports over 20 years. 2007, this device’s year, is highlighted.

FDA decisions per year · FTL

6in 2025

2007: 202008: 232009: 152010: 182011: 152012: 122013: 82014: 112015: 122016: 32017: 62018: 122019: 42020: 52021: 22022: 62023: 42024: 22025: 62026 (partial year): 2
2007high 23 (2008) · low 2 (2021)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · FTL

30in 2025

2007: 92 days median2008: 114 days median2009: 97 days median2010: 132 days median2011: 90 days median2012: 213 days median2013: 90 days median2014: 70 days median2015: 121 days median2016: 186 days median2017: 132 days median2018: 105 days median2019: 99 days median2020: 138 days median2022: 195 days median2023: 29 days median2025: 30 days median
2007high 213 (2012) · low 29 (2023)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · FTL

1in 2020

2007: 22008: 12009: 12010: 122011: 82012: 22013: 12014: 32017: 12018: 12020: 1
2007high 12 (2010) · low 0 (2015)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · FTL

3,487in 2025

2007: 1,7372008: 1,5692009: 1,9062010: 2,1752011: 3,6082012: 14,7002013: 26,5192014: 2,6832015: 2,5262016: 2,4172017: 3,9472018: 11,8932019: 21,7242020: 18,8192021: 16,2842022: 11,4392023: 8,0252024: 8,5652025: 3,487
2007high 26,519 (2013) · low 1,569 (2008)2025

MAUDE reports naming product code FTL, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
2007209221,737
20082311411,569
2009159711,906
201018132122,175
2011159083,608
201212213214,700
2013890126,519
2014117032,683
20151212102,526
2016318602,417
2017613213,947
201812105111,893
2019499021,724
20205138118,819
20212—016,284
20226195011,439
202342908,025
20242—08,565
202563003,487
20262—0—

What is it indicated for?

The Kensey Nash Bioresorbable Surgical Mesh is to be used wherever temporary wound support

is required, to reinforce soft tissues where weakness exists, or for the repair of hernia or other

fascial defects that require the addition of a reinforcing or bridging material to obtain the desired

surgical result. Tissue attachment to the bioresorbable surgical mesh is minimized in case of

direct contact with the viscera.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K071695: Kensey Nash Macropore Shield.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K071695

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026