510(k) Report

510(k) · Cleared

Cleared

Baylis Pain Management Single-Use Probe

K071745510(k) SpecialCleared Jul 19, 200722-day reviewClass II21 CFR 882.4725

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Baylis Medical Co., Inc. · GXI Probe, Radiofrequency Lesion

Cleared on Jul 19, 2007 as substantially equivalent to K002389 (Baylis Medical Co., Inc., 2000) after a 22-day review. Its family tree reaches back 1 generation to 2000.

Decided
Jul 19, 2007
Review
22 days
Class
Class II
Product code
GXI
Recalls
None
Predicates
1

Its longest line of descent runs back 1 generation to K002389 (2000). No later device cites it as a predicate yet.

  1. Root · 1 generation backK002389 Baylis Pain Management Probe/PMP-20-145 and Baylis Pain Management…Baylis Medical Co., Inc. · 2000
  2. This deviceK071745 Baylis Pain Management Single-Use ProbeBaylis Medical Co., Inc. · 2007
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−1K002389Baylis Pain Management Probe/PMP-20-145 and Baylis Pain Management Connector…Baylis Medical Co., Inc.2000—
0 (this device)K071745Baylis Pain Management Single-Use ProbeBaylis Medical Co., Inc.2007—
FIG. 1 — Lineage of K071745, 2000–2007Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in GXI? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new GXI device

  1. #1 K253907 Disposable Radiofrequency Cannulascore 12.7 · 6 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K002389Baylis Pain Management Probe/PMP-20-145 and Baylis Pain Management Connector…
Summary page 1
…. Device Code: GXI Identification of Predicate Device Predicate device is the Baylis Pain Management Probe, which is cleared under 510(k) Premarket Notification Number K002389. Device Description The Baylis Pain Management Single-Use Probe is a sterile, single-use device that delivers Radiofrequency (R…
Baylis Medical Co., Inc.2000—

Also cleared against K002389: 3 other devices →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • Its one ancestor has no recall.
  • 3 other devices also cite its predicate K002389.

How does its category compare?

All GXI devices

GXI Probe, Radiofrequency Lesion: FDA decisions, review times, recalls and adverse event reports over 20 years. 2007, this device’s year, is highlighted.

FDA decisions per year · GXI

4in 2025

2007: 42008: 22009: 22010: 22011: 32012: 12013: 12014: 12015: 12016: 32017: 32018: 12019: 32020: 32022: 22025: 42026 (partial year): 2
2007high 4 (2007) · low 0 (2021)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · GXI

183in 2025

2007: 87 days median2011: 64 days median2016: 240 days median2017: 125 days median2019: 63 days median2020: 255 days median2025: 183 days median
2007high 255 (2020) · low 63 (2019)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · GXI

1in 2019

2007: 32008: 12010: 12012: 12013: 12017: 12019: 12026 (partial year): 3
2007high 3 (2007) · low 0 (2009)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · GXI

98in 2025

2007: 12008: 42009: 102010: 82011: 52012: 142013: 252014: 202015: 232016: 162017: 1502018: 1472019: 932020: 312021: 302022: 462023: 352024: 452025: 98
2007high 150 (2017) · low 1 (2007)2025

MAUDE reports naming product code GXI, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
200748731
20082—14
20092—010
20102—18
201136405
20121—114
20131—125
20141—020
20151—023
20163240016
201731251150
20181—0147
2019363193
20203255031
20210—030
20222—046
20230—035
20240—045
20254183098
20262—3—

What is it indicated for?

Baylis Pain Management Single-Use Probe will be used in conjunction with a Baylis Pain Management Connector Cable and the Baylis Pain Management Generator to create radiofrequency lesions in nervous tissue.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K071745: Baylis Pain Management Single-Use Probe.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K071745

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026