510(k) · Cleared
Recalled · Class II · 2024Ptfe Flixene Graduated Wall Graft
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Atrium Medical Corp. · DSY Prosthesis, Vascular Graft, Of 6mm And Greater Diameter
Cleared on Aug 14, 2007 after a 33-day review. FDA’s file for it is a 510(k) statement, which names no predicate. 2 later devices descend from it. It has been recalled 18 times.
- Decided
- Aug 14, 2007
- Review
- 33 days
- Class
- Class II
- Product code
- DSY
- Recalls
- 18
- Predicates
- 0
2 later devices descend from it, 2 citing it directly.
- This deviceK071923 Ptfe Flixene Graduated Wall GraftAtrium Medical Corp. · 2007
- Descendant · cites it directly · 0 of its ownK231972 Advanta VXT Vascular Graft, Flixene Vascular GraftAtrium Medical Corporation · 2024
- Descendant · cites it directly · 0 of its ownK093934 Gore Hybrid Vascular GraftW.L. Gore & Associates · 2010
Most influential descendants
Showing 2 of 2 · See allView FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| 0 (this device) | K071923 | Ptfe Flixene Graduated Wall Graft | Atrium Medical Corp. | 2007 | — |
| +1 | K231972 | Advanta VXT Vascular Graft, Flixene Vascular Graft | Atrium Medical Corporation | 2024 | — |
| +1 | K093934 | Gore Hybrid Vascular Graft | W.L. Gore & Associates | 2010 | — |
Descendants by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 2010 | 1 | 0 |
| 2024 | 1 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA 510(k) statement (indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in DSY? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new DSY device
- #1 K252445 Fusion Bioline Vascular Graftscore 12.4 · 5 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against?
FDA’s file for it is a 510(k) statement, which names no predicate.
What descends from it? (2)
2 later devices cite it directly; ranked here by how many devices descend from each in turn.
Has anything in its family been recalled? (0 Class I)
Recalls of this device
| Date | Class | Recall | Root cause | Reason |
|---|---|---|---|---|
| May 3, 2024 | Class II | Z-2003-2024 | Equipment maintenance | Complaints of reported separation of the Slider GDS Swivel Rod from the Swivel Core and of a notable gap between the two pieces. |
| May 3, 2024 | Class II | Z-2010-2024 | Equipment maintenance | Complaints of reported separation of the Slider GDS Swivel Rod from the Swivel Core and of a notable gap between the two pieces. |
| May 3, 2024 | Class II | Z-2015-2024 | Equipment maintenance | Complaints of reported separation of the Slider GDS Swivel Rod from the Swivel Core and of a notable gap between the two pieces. |
| May 3, 2024 | Class II | Z-2012-2024 | Equipment maintenance | Complaints of reported separation of the Slider GDS Swivel Rod from the Swivel Core and of a notable gap between the two pieces. |
| May 3, 2024 | Class II | Z-2009-2024 | Equipment maintenance | Complaints of reported separation of the Slider GDS Swivel Rod from the Swivel Core and of a notable gap between the two pieces. |
| May 3, 2024 | Class II | Z-2002-2024 | Equipment maintenance | Complaints of reported separation of the Slider GDS Swivel Rod from the Swivel Core and of a notable gap between the two pieces. |
| May 3, 2024 | Class II | Z-2006-2024 | Equipment maintenance | Complaints of reported separation of the Slider GDS Swivel Rod from the Swivel Core and of a notable gap between the two pieces. |
| May 3, 2024 | Class II | Z-2013-2024 | Equipment maintenance | Complaints of reported separation of the Slider GDS Swivel Rod from the Swivel Core and of a notable gap between the two pieces. |
| May 3, 2024 | Class II | Z-2007-2024 | Equipment maintenance | Complaints of reported separation of the Slider GDS Swivel Rod from the Swivel Core and of a notable gap between the two pieces. |
| May 3, 2024 | Class II | Z-2008-2024 | Equipment maintenance | Complaints of reported separation of the Slider GDS Swivel Rod from the Swivel Core and of a notable gap between the two pieces. |
| May 3, 2024 | Class II | Z-2014-2024 | Equipment maintenance | Complaints of reported separation of the Slider GDS Swivel Rod from the Swivel Core and of a notable gap between the two pieces. |
| May 3, 2024 | Class II | Z-2011-2024 | Equipment maintenance | Complaints of reported separation of the Slider GDS Swivel Rod from the Swivel Core and of a notable gap between the two pieces. |
| May 3, 2024 | Class II | Z-2004-2024 | Equipment maintenance | Complaints of reported separation of the Slider GDS Swivel Rod from the Swivel Core and of a notable gap between the two pieces. |
| May 3, 2024 | Class II | Z-2018-2024 | Equipment maintenance | Complaints of reported separation of the Slider GDS Swivel Rod from the Swivel Core and of a notable gap between the two pieces. |
| May 3, 2024 | Class II | Z-2005-2024 | Equipment maintenance | Complaints of reported separation of the Slider GDS Swivel Rod from the Swivel Core and of a notable gap between the two pieces. |
| May 3, 2024 | Class II | Z-2017-2024 | Equipment maintenance | Complaints of reported separation of the Slider GDS Swivel Rod from the Swivel Core and of a notable gap between the two pieces. |
| May 3, 2024 | Class II | Z-2016-2024 | Equipment maintenance | Complaints of reported separation of the Slider GDS Swivel Rod from the Swivel Core and of a notable gap between the two pieces. |
| Jul 12, 2013 | Class II | Z-2314-2013 | Package design/selection | Inner tray label may adhere to wall of outer tray which make it difficult to remove the tray onto the sterile field |
The 5 latest of 18 recalls; the web page lists all.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- Of its descendants, K231972 (Atrium Medical Corporation, 2024) has gone furthest, with 0 descendants of its own.
How does its category compare?
All DSY devicesDSY Prosthesis, Vascular Graft, Of 6mm And Greater Diameter: FDA decisions, review times, recalls and adverse event reports over 20 years. 2007, this device’s year, is highlighted.
FDA decisions per year · DSY
2in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · DSY
160in 2024
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · DSY
1in 2025
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · DSY
151in 2025
MAUDE reports naming product code DSY, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 1 | — | 0 | 120 |
| 2008 | 1 | — | 0 | 164 |
| 2009 | 5 | 73 | 2 | 193 |
| 2010 | 4 | 55 | 5 | 187 |
| 2011 | 1 | — | 0 | 165 |
| 2012 | 4 | 30 | 0 | 177 |
| 2013 | 5 | 69 | 1 | 207 |
| 2014 | 2 | — | 0 | 352 |
| 2015 | 1 | — | 0 | 460 |
| 2016 | 1 | — | 2 | 217 |
| 2017 | 3 | 269 | 0 | 193 |
| 2018 | 1 | — | 0 | 200 |
| 2019 | 1 | — | 0 | 232 |
| 2020 | 1 | — | 0 | 169 |
| 2021 | 2 | — | 0 | 168 |
| 2022 | 2 | — | 0 | 155 |
| 2023 | 2 | — | 0 | 149 |
| 2024 | 5 | 160 | 0 | 153 |
| 2025 | 2 | — | 1 | 151 |
| 2026 | 1 | — | 1 | — |
What is it indicated for?
The Atrium Graduated Wall Flixene Graft is intended for use in arterial vascular reconstruction, segmental bypass, and for arteriovenous vascular access.
Indications for use as stated in the FDA 510(k) statement.
https://510kreport.com/device/K071923 · printed Nov 5, 2026
Cite this page
510(k) Report. “K071923: Ptfe Flixene Graduated Wall Graft.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 5, 2026. https://510kreport.com/device/K071923
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026