510(k) Report

510(k) · Cleared

Recalled · 2011

Restoration Adm System

K072020510(k) TraditionalCleared Oct 18, 200787-day reviewClass II21 CFR 888.3353Recalls 1

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Howmedica Osteonics Corp. · MEH Prosthesis, Hip, Semi-Constrained, Uncemented, Metal / Polymer, Non-Porous, Calcium Phosphate

Cleared on Oct 18, 2007 after an 87-day review. The FDA summary names its predicate without a number. 95 later devices descend from it. It has been recalled once.

Decided
Oct 18, 2007
Review
87 days
Class
Class II
Product code
MEH
Recalls
1
Predicates
0

95 later devices descend from it, 10 citing it directly.

Descendants, by year cleared 2009: 1 descendant cleared2018: 5 descendants cleared2023: 7 descendants cleared2016: 3 descendants cleared2022: 9 descendants cleared2011: 9 descendants cleared2012: 5 descendants cleared2015: 3 descendants cleared2010: 1 descendant cleared2013: 2 descendants cleared2019: 8 descendants cleared2025: 12 descendants cleared2020: 3 descendants cleared2021: 8 descendants cleared2017: 3 descendants cleared2026: 6 descendants cleared2014: 1 descendant cleared2024: 9 descendants cleared20052010201520202025
  1. This deviceK072020 Restoration Adm SystemHowmedica Osteonics Corp. · 2007
  2. Descendant · cites it directly · 59 of its ownK083116 Versafit Cup Double Mobility SystemMedacta International S.A. · 2009 · Recalled
  3. Descendant · cites it directly · 52 of its ownK103233 Modular Dual Mobility Liner, X3 Acetabular InsertHowmedica Osteonics Corp. · 2011 · Recalled
  4. Descendant · cites it directly · 27 of its ownK111572 Novae Sunfit TH Dual Mobility Acetabular Cup Model Sunfit TH…Serf · 2011 · Recalled
  5. Descendant · cites it directly · 24 of its ownK101336 E1 Avantage HeadBiomet Manufacturing Corp · 2011 · Recalled
  6. Descendant · 2 generations on · 23 of its ownK092265 Vesafitcup Double Mobility- Highcross Hxuhmwpe LinersMedacta International S.A. · 2010

Showing 5 of 95 descendants. See all descendants

Descendants cleared per year

2009: 12010: 12011: 92012: 52013: 22014: 12015: 32016: 32017: 32018: 52019: 82020: 32021: 82022: 92023: 72024: 92025: 122026: 6
2009high 12 (2025) · low 1 (2009)2026

Most influential descendants

Showing 5 of 95 · See all
  • K083116Versafit Cup Double Mobility SystemMedacta International S.A. · 2009 · cites it directly59descendants
  • K103233Modular Dual Mobility Liner, X3 Acetabular InsertHowmedica Osteonics Corp. · 2011 · cites it directly52descendants
  • K111572Novae Sunfit TH Dual Mobility Acetabular Cup Model Sunfit TH (Metal-Back), Novae E TH…Serf · 2011 · cites it directly27descendants
  • K101336E1 Avantage HeadBiomet Manufacturing Corp · 2011 · cites it directly24descendants
  • K092265Vesafitcup Double Mobility- Highcross Hxuhmwpe LinersMedacta International S.A. · 2010 · 2 generations on23descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
0 (this device)K072020Restoration Adm SystemHowmedica Osteonics Corp.2007—
+1K083116Versafit Cup Double Mobility SystemMedacta International S.A.20092
+1K103233Modular Dual Mobility Liner, X3 Acetabular InsertHowmedica Osteonics Corp.20111
+1K111572Novae Sunfit TH Dual Mobility Acetabular Cup Model Sunfit TH (Metal-Back)…Serf20115
+1K101336E1 Avantage HeadBiomet Manufacturing Corp20111
+2K092265Vesafitcup Double Mobility- Highcross Hxuhmwpe LinersMedacta International S.A.2010—

Descendants by year cleared

Year clearedDevicesWith a Class I recall
200910
201010
201190
201250
201320
201410
201530
201630
201730
201850
201980
202030
202180
202290
202370
202490
2025120
202660
FIG. 1 — Lineage of K072020, 2007–2026Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in MEH? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new MEH device

  1. #1 K210581 Actis DuoFix Hip Prosthesis- Collarlessscore 23.9 · 16 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (4)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*—Trident® Acetabular System
Named without a submission number
—
*—Biomet Tri-Polar System
Named without a submission number
—
*—Plus Orthopaedics Ag Polarcup Dual Mobility System
Named without a submission number
—
*—UHR Bipolar System
Named without a submission number
—

What descends from it? (95)

See all 95

10 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K083116Versafit Cup Double Mobility SystemMedacta International S.A.200959
K103233Modular Dual Mobility Liner, X3 Acetabular InsertHowmedica Osteonics Corp.201152
K111572Novae Sunfit TH Dual Mobility Acetabular Cup Model Sunfit TH (Metal-Back), Novae E TH…Serf201127
K101336E1 Avantage HeadBiomet Manufacturing Corp201124
K153345Stryker Orthopaedics Hip Systems Labeling UpdateStryker Orthopaedics201617
K112556Adm and Adm/MDM Duration Inserts, Adm and Adm/MDM X3 InsertsHowmedica Osteonics Corp.201110
K171273LINK® BiMobile (TM) Dual Mobility SystemWaldemar Link GmbH & Co. KG20184
K211742SignaSure Dual Mobility SystemSignature Orthopaedics Pty, Ltd.20222
K220495SignaSure Dual Mobility SystemSignature Orthopaedics Pty, Ltd.20231
K111981Tregor Dual Mobility Acetabular SystemAston Medical20120

Has anything in its family been recalled? (0 Class I)

Recalls of this device

DateClassRecallRoot causeReason
Jun 3, 2011Not classifiedZ-0194-2012Labeling False and MisleadingStryker Orthopaedics has become ware that there is the potential for interpretation of the product labeling which may lead to an incorrect implant being used.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • Of its descendants, K083116 (Medacta International S.A., 2009) has gone furthest, with 59 descendants of its own.

How does its category compare?

All MEH devices

MEH Prosthesis, Hip, Semi-Constrained, Uncemented, Metal / Polymer, Non-Porous, Calcium Phosphate: FDA decisions, review times, recalls and adverse event reports over 20 years. 2007, this device’s year, is highlighted.

FDA decisions per year · MEH

5in 2025

2007: 22008: 62009: 62010: 52011: 52012: 62013: 12015: 22016: 62017: 32018: 22019: 12020: 32021: 32022: 32023: 22024: 62025: 52026 (partial year): 1
2007high 6 (2008) · low 0 (2014)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · MEH

87in 2025

2008: 79 days median2009: 65 days median2010: 226 days median2011: 95 days median2012: 131 days median2016: 163 days median2017: 209 days median2020: 131 days median2021: 83 days median2022: 150 days median2024: 91 days median2025: 87 days median
2007high 226 (2010) · low 65 (2009)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · MEH

1in 2025

2007: 32008: 802009: 512010: 162011: 42012: 32014: 12015: 12016: 42017: 12018: 32020: 12025: 12026 (partial year): 1
2007high 80 (2008) · low 0 (2013)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · MEH

470in 2025

2007: 252008: 2612009: 5392010: 4622011: 4192012: 1,6062013: 1,2952014: 1,1962015: 4902016: 3472017: 3832018: 3372019: 3352020: 3382021: 3722022: 3162023: 3342024: 3542025: 470
2007high 1,606 (2012) · low 25 (2007)2025

MAUDE reports naming product code MEH, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20072—325
200867980261
200966551539
2010522616462
20115954419
2012613131,606
20131—01,295
20140—11,196
20152—1490
201661634347
201732091383
20182—3337
20191—0335
202031311338
20213830372
202231500316
20232—0334
20246910354
20255871470
20261—1—

What is it indicated for?

The indications for use of the total hip replacement prostheses include:

1) Noninflammatory degenerative joint disease including osteoarthritis and avascular necrosis;

2) Rheumatoid arthritis

3) Correction of functional deformity;

4) Revision procedures where other treatments or devices have failed;

5) Treatment of nonunion, femoral neck and trochanterie fractures of the proximal femur with head involvement that are unmanageable using other techniques.

6) Dislocation risks

This acetabular cup is intended for cementless use only.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K072020: Restoration Adm System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K072020

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026