510(k) Report

510(k) · Cleared

Cleared

Continuous Non-Invasive Cardiac Output and Blood Pressure Monitor with Real-Time Hemodynamics

K072049510(k) TraditionalCleared Nov 29, 2007127-day reviewClass II21 CFR 870.1130

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Bmeye B.V. · DXN System, Measurement, Blood-Pressure, Non-Invasive

Cleared on Nov 29, 2007 as substantially equivalent to K023723 (Fms, Finapres Medical Systems BV, 2003) after a 127-day review. Its family tree reaches back 3 generations to 1988. 1 of the 84 devices in its family, counting itself, has a Class I recall. 78 later devices descend from it.

Decided
Nov 29, 2007
Review
127 days
Class
Class II
Product code
DXN
Recalls
None
Predicates
1

Its longest line of descent runs back 3 generations to K880572 (1988). 5 ancestors in all, the oldest K822055 (1982). 78 later devices descend from it, 6 citing it directly. 1 of the 84 devices in this family, counting this one, has a Class I recall.

Other ancestors, by year clearedDescendants, by year cleared 1982: 1 other ancestor2000: 1 other ancestor2017: 3 descendants cleared2015: 2 descendants cleared2022: 8 descendants cleared2010: 2 descendants cleared2016: 2 descendants cleared, 1 with a Class I recall12013: 2 descendants cleared2018: 3 descendants cleared2021: 8 descendants cleared2025: 11 descendants cleared2019: 8 descendants cleared2014: 1 descendant cleared2023: 13 descendants cleared2024: 6 descendants cleared2026: 8 descendants cleared2020: 1 descendant clearedK880572 · Ohmeda 2350 Finapres (R) Blood Pressure Monitor · Ohmeda Medical · 1988K014063 · Task Force Monitor 3040 · Cnsystems Medizintechnik GmbH · 2002 · recalledK023723 · Finometer Noninvasive Hemodynamic Monitor, Model 1 · Fms, Finapres Medical Systems BV · 200319801990200020102020
Other ancestors, by generationDescendants, by generation 2 generations back: 1 other ancestor3 generations back: 1 other ancestor 1 generation forward: 6 descendants2 generations forward: 7 descendants3 generations forward: 9 descendants4 generations forward: 8 descendants, 1 with a Class I recall15 generations forward: 11 descendants6 generations forward: 13 descendants7 generations forward: 10 descendants8 generations forward: 8 descendants9 generations forward: 6 descendants K023723 · Finometer Noninvasive Hemodynamic Monitor, Model 1 · Fms, Finapres Medical Systems BV · 2003K014063 · Task Force Monitor 3040 · Cnsystems Medizintechnik GmbH · 2002 · recalledK880572 · Ohmeda 2350 Finapres (R) Blood Pressure Monitor · Ohmeda Medical · 19880+5
  1. Root · 3 generations backK880572 Ohmeda 2350 Finapres (R) Blood Pressure MonitorOhmeda Medical · 1988
  2. 2 generations backK014063 Task Force Monitor 3040Cnsystems Medizintechnik GmbH · 2002 · Recalled
  3. 1 generation backK023723 Finometer Noninvasive Hemodynamic Monitor, Model 1Fms, Finapres Medical Systems BV · 2003
  4. This deviceK072049 Continuous Non-Invasive Cardiac Output and Blood Pressure Monitor…Bmeye B.V. · 2007
  5. Descendant · cites it directly · 54 of its ownK101123 Nexfin Model 2Bmeye B.V. · 2010
  6. Descendant · 2 generations on · 53 of its ownK122381 Nexfin Model 2Edwards Lifesciences, LLC · 2013
  7. Descendant · 3 generations on · 52 of its ownK140312 EV1000 Clinical Platform with Clearsight TM Finger Cuff or…Edwards Lifesciences, LLC · 2014 · Recalled
  8. Descendant · 4 generations on · 51 of its ownK160552 EV1000 Clinical Platform with ClearSight Finger Cuff or ClearSight…Edwards Lifesciences, LLC · 2016 · Recalled (Class I)
  9. Descendant · 5 generations on · 41 of its ownK163381 HemoSphere Advanced Monitor, HemoSphere Swan-Ganz Module, HemoSphere…Edwards Lifesciences, LLC · 2017 · Recalled

Showing 5 of 78 descendants. See all descendants

Descendants cleared per year

2010: 22013: 22014: 12015: 22016: 22017: 32018: 32019: 82020: 12021: 82022: 82023: 132024: 62025: 112026: 8
2010high 13 (2023) · low 0 (2011)2026

Class I recalls in this family

Most influential descendants

Showing 5 of 78 · See all
  • K101123Nexfin Model 2Bmeye B.V. · 2010 · cites it directly54descendants
  • K122381Nexfin Model 2Edwards Lifesciences, LLC · 2013 · 2 generations on53descendants
  • K140312EV1000 Clinical Platform with Clearsight TM Finger Cuff or Clearsight TM SystemEdwards Lifesciences, LLC · 2014 · 3 generations on52descendants
  • K160552EV1000 Clinical Platform with ClearSight Finger Cuff or ClearSight System, EV1000…Edwards Lifesciences, LLC · 2016 · 4 generations on51descendants
  • K163381HemoSphere Advanced Monitor, HemoSphere Swan-Ganz Module, HemoSphere Oximetry CableEdwards Lifesciences, LLC · 2017 · 5 generations on41descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−3K880572Ohmeda 2350 Finapres (R) Blood Pressure MonitorOhmeda Medical1988—
−2K014063Task Force Monitor 3040Cnsystems Medizintechnik GmbH20021
−1K023723Finometer Noninvasive Hemodynamic Monitor, Model 1Fms, Finapres Medical Systems BV2003—
0 (this device)K072049Continuous Non-Invasive Cardiac Output and Blood Pressure Monitor with…Bmeye B.V.2007—
+1K101123Nexfin Model 2Bmeye B.V.2010—
+2K122381Nexfin Model 2Edwards Lifesciences, LLC2013—
+3K140312EV1000 Clinical Platform with Clearsight TM Finger Cuff or Clearsight TM SystemEdwards Lifesciences, LLC20141
+4K160552EV1000 Clinical Platform with ClearSight Finger Cuff or ClearSight System…Edwards Lifesciences, LLC2016Class I
+5K163381HemoSphere Advanced Monitor, HemoSphere Swan-Ganz Module, HemoSphere Oximetry…Edwards Lifesciences, LLC20172

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
198210
200010

Descendants by year cleared

Year clearedDevicesWith a Class I recall
201020
201320
201410
201520
201621
201730
201830
201980
202010
202180
202280
2023130
202460
2025110
202680
FIG. 1 — Lineage of K072049, 1988–2026Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

1 device in this family has a Class I recall. A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new DXN device

  1. #1 K222125 Arm Blood Pressure Monitor, models AOJ-30A…score 18.5 · 8 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K023723Finometer Noninvasive Hemodynamic Monitor, Model 1
Summary page 1
…essure, non-invasive, DXN Name - CFR 870.2770, Plethysmograph, impedance, DSB Predicate: The NEXFINHD is substantially equivalent to the Finometer (K023723). Device The BMEYE NEXFIN HD cardiovascular monitor is a non-invasive monitor that description enables the con…
Fms, Finapres Medical Systems BV2003—

Also cleared against K023723: 2 other devices →

What descends from it? (78)

See all 78

6 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K101123Nexfin Model 2Bmeye B.V.201054
K151499CareTaker Continuous Non-Invasive Blood Pressure Monitor, CareTaker Wireless VItal Signs…Caretaker Medical, LLC201616
K163255CareTaker Continuous Non-lnvasive Blood Pressure Monitor, CareTaker Wireless Vital Signs…Caretaker Medical, LLC201715
K141460Finapres Nova Noninvasive Hemodynamic MonitorFinapres Medical Systems B.V.20154
K091564NBM-200MP Pulse Oximetry DeviceOrsense, Ltd.20102
K213699CareTaker Monitor AppCaretaker Medical, LLC20220

Has anything in its family been recalled? (1 Class I)

No FDA recall names this device.

Relatives with a Class I recall

Class I is FDA’s most serious recall class. A recall in the family tree is context for this device, not evidence about it.

  • K160552EV1000 Clinical Platform with ClearSight Finger Cuff or ClearSight System, EV1000 Clinical PlatformEdwards Lifesciences, LLC · 2016 · 4 generations on · ◆ in the 2016 descendants bar of FIG. 11 Class I recall

What does this lineage say?

  • The line of descent spans 19 years and passes through 4 companies; a new generation was cleared every 4.1 years on median.
  • 1 of the 5 ancestors has a recall of any class.
  • Of its descendants, K101123 (Bmeye B.V., 2010) has gone furthest, with 54 descendants of its own.
  • 2 other devices also cite its predicate K023723.

How does its category compare?

All DXN devices

DXN System, Measurement, Blood-Pressure, Non-Invasive: FDA decisions, review times, recalls and adverse event reports over 20 years. 2007, this device’s year, is highlighted.

FDA decisions per year · DXN

28in 2025

2007: 272008: 232009: 462010: 432011: 342012: 362013: 342014: 292015: 302016: 302017: 332018: 222019: 332020: 242021: 232022: 252023: 352024: 172025: 282026 (partial year): 29
2007high 46 (2009) · low 17 (2024)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · DXN

142in 2025

2007: 118 days median2008: 82 days median2009: 73 days median2010: 94 days median2011: 72 days median2012: 116 days median2013: 150 days median2014: 133 days median2015: 97 days median2016: 144 days median2017: 184 days median2018: 235 days median2019: 156 days median2020: 198 days median2021: 190 days median2022: 137 days median2023: 182 days median2024: 107 days median2025: 142 days median2026 (partial year): 147 days median
2007high 235 (2018) · low 72 (2011)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · DXN

3in 2024

2008: 12009: 32011: 12013: 12016: 12019: 12024: 3
2007high 3 (2009) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · DXN

239in 2025

2007: 212008: 82009: 172010: 142011: 102012: 192013: 722014: 472015: 622016: 542017: 902018: 6172019: 962020: 1302021: 1622022: 1552023: 1622024: 2702025: 239
2007high 617 (2018) · low 8 (2008)2025

MAUDE reports naming product code DXN, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
200727118021
2008238218
20094673317
20104394014
20113472110
201236116019
201334150172
201429133047
20153097062
201630144154
201733184090
2018222350617
201933156196
2020241980130
2021231900162
2022251370155
2023351820162
2024171073270
2025281420239
2026291470—

What is it indicated for?

The BMEYE NEXFIN._HD is intended to, non-invasively and continuously, measure blood pressure and hemodynamic parameters in adult patients. The NEXFINHD monitor should be calibrated with a thermodilution measurement, or other accurate reference determination of cardiac output, to ensure optimal accuracy. The device is Intended for use by physicians or other properly trained medical personnel in a hospital or other appropriate clinical setting.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K072049: Continuous Non-Invasive Cardiac Output and Blood Pressure Monitor with Real-Time Hemodynamics.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 5, 2026. https://510kreport.com/device/K072049

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026