510(k) Report

510(k) · Cleared

Cleared

Gravilax Traction System

K072064510(k) TraditionalCleared Apr 21, 2008269-day reviewClass II21 CFR 890.5900

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Therapeutic Clinical Technologies, Inc. · ITH Equipment, Traction, Powered

Cleared on Apr 21, 2008 as substantially equivalent to K991835 (Stl Intl., Inc., 1999) and 4 other predicates after a 269-day review. Its family tree reaches back 3 generations to 1989.

Decided
Apr 21, 2008
Review
269 days
Class
Class II
Product code
ITH
Recalls
None
Predicates
5

Its longest line of descent runs back 3 generations to K894435 (1989). 14 ancestors in all, the oldest K821002 (1982). No later device cites it as a predicate yet.

Other ancestors, by year cleared 2006: 1 other ancestor2005: 1 other ancestor2004: 1 other ancestor1999: 1 other ancestor2000: 1 other ancestor1998: 1 other ancestor1995: 1 other ancestor1986: 1 other ancestor1985: 1 other ancestor1982: 1 other ancestor1984: 1 other ancestorK894435 · Vax-T Pelvic Traction Belt · Vat-Tech, Inc. · 1989K951622 · Vax-D Therapeutic Table · Vat-Tech, Inc. · 1996K981822 · DRS System · Professional Distribution Systems, Inc. · 19981980198519901995200020052010
Other ancestors, by generation 1 generation back: 4 other ancestors2 generations back: 6 other ancestors3 generations back: 1 other ancestor K981822 · DRS System · Professional Distribution Systems, Inc. · 1998K951622 · Vax-D Therapeutic Table · Vat-Tech, Inc. · 1996K894435 · Vax-T Pelvic Traction Belt · Vat-Tech, Inc. · 19890
  1. Root · 3 generations backK894435 Vax-T Pelvic Traction BeltVat-Tech, Inc. · 1989
  2. 2 generations backK951622 Vax-D Therapeutic TableVat-Tech, Inc. · 1996
  3. 1 generation backK981822 DRS SystemProfessional Distribution Systems, Inc. · 1998
  4. This deviceK072064 Gravilax Traction SystemTherapeutic Clinical Technologies, Inc. · 2008
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−3K894435Vax-T Pelvic Traction BeltVat-Tech, Inc.1989—
−2K951622Vax-D Therapeutic TableVat-Tech, Inc.1996—
−1K981822DRS SystemProfessional Distribution Systems, Inc.1998—
0 (this device)K072064Gravilax Traction SystemTherapeutic Clinical Technologies, Inc.2008—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
198210
198410
198510
198610
199510
199810
199910
200010
200410
200510
200610
FIG. 1 — Lineage of K072064, 1989–2008Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in ITH? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new ITH device

  1. #1 K243775 True Non-Surgical Spinal Decompression System…score 10.6 · 4 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (5)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K991835Hang Ups Power II
Summary page 1
…r traction devices which achieve their effect through the force of gravity and/or mechanical means, including the following: HangUps InvertAlign; STL International Inc. K991835; BAX-D Genesis System; VAD-D Medical Technology Services, LLC. K053503; Digit-Trac 930 Traction System; Ever Prosperous Instrumen…
Stl Intl., Inc.1999—
*K053503Vax-D Genesis System (Therapeutic Table)
Summary page 1
…ity and/or mechanical means, including the following: HangUps InvertAlign; STL International Inc. K991835; BAX-D Genesis System; VAD-D Medical Technology Services, LLC. K053503; Digit-Trac 930 Traction System; Ever Prosperous Instrument, Inc. K052453; Extentrac Elite; Advanced Back Technologies, Inc. K031…
Vax-D Medical Technologies USA, L.C.2005—
*K052453Traction System, Digit-Trac 930
Summary page 1
…; STL International Inc. K991835; BAX-D Genesis System; VAD-D Medical Technology Services, LLC. K053503; Digit-Trac 930 Traction System; Ever Prosperous Instrument, Inc. K052453; Extentrac Elite; Advanced Back Technologies, Inc. K031996; and DRS System; Professional Distribution Systems, Inc. K981822. Ind…
Ever Prosperous Instrument, Inc.2006—
*K031996Extentrac Elite
Summary page 1
…-D Medical Technology Services, LLC. K053503; Digit-Trac 930 Traction System; Ever Prosperous Instrument, Inc. K052453; Extentrac Elite; Advanced Back Technologies, Inc. K031996; and DRS System; Professional Distribution Systems, Inc. K981822. Indications for Use: The GraviLax Traction System is intended…
Advanced Back Technologies20042
*K981822DRS System
Summary page 1
…tion System; Ever Prosperous Instrument, Inc. K052453; Extentrac Elite; Advanced Back Technologies, Inc. K031996; and DRS System; Professional Distribution Systems, Inc. K981822. Indications for Use: The GraviLax Traction System is intended for use in exerting therapeutic pulling force on the patient's bo…
Professional Distribution Systems, Inc.1998—

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 19 years and passes through 3 companies; a new generation was cleared every 6.9 years on median.
  • 1 of the 14 ancestors has a recall of any class.

How does its category compare?

All ITH devices

ITH Equipment, Traction, Powered: FDA decisions, review times, recalls and adverse event reports over 20 years. 2008, this device’s year, is highlighted.

FDA decisions per year · ITH

2in 2025

2007: 22008: 42009: 12010: 12011: 12012: 12014: 22015: 22023: 12024: 12025: 2
2007high 4 (2008) · low 0 (2013)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · ITH

132in 2008

2008: 132 days median
2007high 132 (2008)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · ITH

2in 2011

2011: 2
2007high 2 (2011) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · ITH

3in 2025

2007: 22009: 32010: 32011: 52012: 12013: 22014: 52015: 12016: 22017: 22019: 52021: 12023: 12024: 52025: 3
2007high 5 (2011) · low 0 (2008)2025

MAUDE reports naming product code ITH, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20072—02
2008413200
20091—03
20101—03
20111—25
20121—01
20130—02
20142—05
20152—01
20160—02
20170—02
20180—00
20190—05
20200—00
20210—01
20220—00
20231—01
20241—05
20252—03
20260—0—

What is it indicated for?

The GraviLax Traction System is intended for use in exerting therapeutic pulling forces on the patient's body. The device utilizes a cylindrical hot tub in which the patient is suspended vertically by a shoulder harness and which contains salt water whose salinity is adjusted to a specific gravity of approximately 1.2 providing an increased natural buoyancy to the user's body. Decompressive force (unloading due to distraction and positioning) to the sacral, lumbar and thoracic spine is achieved by application of suitable weights to the patient's ankles This device is for prescription use only and is limited to use by qualified personnel in a suitably equipped treatment facility.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K072064: Gravilax Traction System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K072064

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026