510(k) Report

510(k) · Cleared

Cleared

Comfortpress Vascular Compression Assist Device

K072167510(k) SpecialCleared Sep 6, 200731-day reviewClass II21 CFR 870.4450

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Advanced Vascular Dynamics · DXC Clamp, Vascular

Cleared on Sep 6, 2007 as substantially equivalent to K053398 (Semler Technologies, Inc. Dba, 2006) after a 31-day review. Its family tree reaches back 1 generation to 2006.

Decided
Sep 6, 2007
Review
31 days
Class
Class II
Product code
DXC
Recalls
None
Predicates
1

Its longest line of descent runs back 1 generation to K053398 (2006). No later device cites it as a predicate yet.

K053398 · Compass Compression Assist Handle · Semler Technologies, Inc. Dba · 200620062008
  1. Root · 1 generation backK053398 Compass Compression Assist HandleSemler Technologies, Inc. Dba · 2006
  2. This deviceK072167 Comfortpress Vascular Compression Assist DeviceAdvanced Vascular Dynamics · 2007
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−1K053398Compass Compression Assist HandleSemler Technologies, Inc. Dba2006—
0 (this device)K072167Comfortpress Vascular Compression Assist DeviceAdvanced Vascular Dynamics2007—
FIG. 1 — Lineage of K072167, 2006–2007Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in DXC? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new DXC device

  1. #1 K262086 PreludeSYNC™ Radial Compression Devicescore 13.5 · 7 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K053398Compass Compression Assist Handle
Summary page 1
…andle Common name - femoral access compression device Classification name - Clamp, Vascular (21 CFR 870.4450 DXC) Predicate device - CompassTM Compression Assist Handle (K053398) This device handle is similar to the Compass handle, but of a different shape. The ComfortPress device provides an alternative…
Semler Technologies, Inc. Dba2006—

Also cleared against K053398: 1 other device →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • Its one ancestor has no recall.
  • 1 other device also cites its predicate K053398.

How does its category compare?

All DXC devices

DXC Clamp, Vascular: FDA decisions, review times, recalls and adverse event reports over 20 years. 2007, this device’s year, is highlighted.

FDA decisions per year · DXC

2in 2025

2007: 102008: 32009: 42010: 22011: 62012: 52013: 142014: 42015: 52016: 32017: 32018: 22019: 22020: 32021: 62022: 12023: 42024: 12025: 22026 (partial year): 4
2007high 14 (2013) · low 1 (2022)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · DXC

215in 2023

2007: 52 days median2008: 29 days median2009: 83 days median2011: 51 days median2012: 73 days median2013: 89 days median2014: 157 days median2015: 71 days median2016: 91 days median2017: 90 days median2020: 209 days median2021: 37 days median2023: 215 days median2026 (partial year): 125 days median
2007high 215 (2023) · low 29 (2008)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · DXC

2in 2023

2008: 22009: 22010: 12011: 32014: 12022: 12023: 2
2007high 3 (2011) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · DXC

442in 2025

2007: 2982008: 3022009: 5392010: 6002011: 6912012: 5482013: 9202014: 4942015: 3742016: 4942017: 4162018: 3912019: 3932020: 4042021: 3712022: 2732023: 6742024: 3752025: 442
2007high 920 (2013) · low 273 (2022)2025

MAUDE reports naming product code DXC, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
200710520298
20083292302
20094832539
20102—1600
20116513691
20125730548
201314890920
201441571494
20155710374
20163910494
20173900416
20182—0391
20192—0393
202032090404
20216370371
20221—1273
202342152674
20241—0375
20252—0442
202641250—

What is it indicated for?

This device is indicated for use to provide hemostasis of the femoral vascular access site

during and following catheterization or cannulation procedures.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K072167: Comfortpress Vascular Compression Assist Device.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 5, 2026. https://510kreport.com/device/K072167

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026