510(k) · Cleared
Recalled · Class II · 2017Cook Fiber Optic Bundle and Flexor Deflecting Access Sheath
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Cook Urological, Inc. · FFS Image, Illumination, Fiberoptic, For Endoscope
Cleared on Nov 20, 2007 as substantially equivalent to K925128 (KARL STORZ Endoscopy-America, Inc., 1993) and 3 other predicates after a 74-day review. Its family tree reaches back 3 generations to 1999. It has been recalled once.
- Decided
- Nov 20, 2007
- Review
- 74 days
- Class
- Class II
- Product code
- FFS
- Recalls
- 1
- Predicates
- 4
Its longest line of descent runs back 3 generations to K990775 (1999). 10 ancestors in all, the oldest K922826 (1993). No later device cites it as a predicate yet.
- Root · 3 generations backK990775 Ureteral Access Sheath SetApplied Medical Resources · 1999
- 2 generations backK993650 Ureteral Access Sheath Set - New ModelsApplied Medical Resources · 1999
- 1 generation backK030642 Deflecting Ureteral Access SheathApplied Medical Resources Corp. · 2003
- This deviceK072521 Cook Fiber Optic Bundle and Flexor Deflecting Access SheathCook Urological, Inc. · 2007
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −3 | K990775 | Ureteral Access Sheath Set | Applied Medical Resources | 1999 | — |
| −2 | K993650 | Ureteral Access Sheath Set - New Models | Applied Medical Resources | 1999 | — |
| −1 | K030642 | Deflecting Ureteral Access Sheath | Applied Medical Resources Corp. | 2003 | — |
| 0 (this device) | K072521 | Cook Fiber Optic Bundle and Flexor Deflecting Access Sheath | Cook Urological, Inc. | 2007 | — |
Other ancestors by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 1993 | 2 | 0 |
| 1996 | 1 | 0 |
| 2003 | 3 | 0 |
| 2005 | 1 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in FFS? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
- Candidate predicates for a device like this, rankedin the report
- Recall history across each candidate’s familyin the report
What was it cleared against? (4)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K925128 | The Karl Storz 11274 Series Flexible FiberscopeSummary page 1…tions for use and technology to existing predicate devices incommercial distribution. Specifically, The Cook® Fiber Optic Bundle is similar to the Karl Storz Fiberscope (K925128/B) manufactured by Kail Storz Endoscope and the Flexible Fiber Optic Bundle(K922826) manufactured by Optimed Technologies, Incorp… | 1993 |
| * | K922826 | Flexible Fiber Optic EndoscopeSummary page 1…. Specifically, The Cook® Fiber Optic Bundle is similar to the Karl Storz Fiberscope (K925128/B) manufactured by Kail Storz Endoscope and the Flexible Fiber Optic Bundle(K922826) manufactured by Optimed Technologies, Incorporated. The Deflecting Flexor Access Sheath is similar to the Flexor DL Ureteral Acc… | 1993 |
| * | K043418 | Cook Pediatric Flexor Ureteral Access ShealthSummary page 1…e Fiber Optic Bundle(K922826) manufactured by Optimed Technologies, Incorporated. The Deflecting Flexor Access Sheath is similar to the Flexor DL Ureteral Access Sheath (K04341 8) manufactured by Cook Urological, Incorporated and the Fadte' Plus Deflecting Renal Access Sheath (K030642) manufactured by Appli… | 2005 |
| * | K030642 | Deflecting Ureteral Access SheathSummary page 1…ss Sheath is similar to the Flexor DL Ureteral Access Sheath (K04341 8) manufactured by Cook Urological, Incorporated and the Fadte' Plus Deflecting Renal Access Sheath (K030642) manufactured by Applied Medical. Device Description: The Cook® Fiber Optic Bundle isa small diameter fiber optic consisting o… | 2003 |
What descends from it?
No later submission names this one as a predicate yet.
Has anything in its family been recalled? (0 Class I)
Recalls of this device
| Date | Class | Recall | Root cause | Reason |
|---|---|---|---|---|
| May 3, 2017 | Class II | Z-2540-2017 | Device Design | Cook Inc. is initiating a voluntary recall of the Vue Optic Visualization Source and the Flexor Vue Deflecting Endoscopic System because it was determined that the current reprocessing instructions do not provide sufficient detailed… |
No ancestor or descendant has a Class I recall.
What does this lineage say?
- The line of descent spans 8 years and passes through 3 companies; a new generation was cleared every 3.4 years on median.
- 2 of the 10 ancestors have a recall of any class.
- 1 other device also cites its predicate K925128.
How does its category compare?
All FFS devicesFFS Image, Illumination, Fiberoptic, For Endoscope: FDA decisions, review times, recalls and adverse event reports over 20 years. 2007, this device’s year, is highlighted.
FDA decisions per year · FFS
3in 2007
2026 to Oct 25, outlined.
Median 510(k) review, days · FFS
74in 2007
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · FFS
1in 2007
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · FFS
5in 2024
MAUDE reports naming product code FFS, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 3 | 74 | 1 | 12 |
| 2008 | 0 | — | 0 | 17 |
| 2009 | 0 | — | 0 | 14 |
| 2010 | 0 | — | 0 | 5 |
| 2011 | 0 | — | 0 | 7 |
| 2012 | 0 | — | 0 | 4 |
| 2013 | 0 | — | 0 | 10 |
| 2014 | 0 | — | 0 | 5 |
| 2015 | 0 | — | 0 | 4 |
| 2016 | 0 | — | 0 | 7 |
| 2017 | 0 | — | 0 | 19 |
| 2018 | 0 | — | 0 | 19 |
| 2019 | 0 | — | 0 | 17 |
| 2020 | 0 | — | 0 | 56 |
| 2021 | 0 | — | 0 | 57 |
| 2022 | 0 | — | 0 | 10 |
| 2023 | 0 | — | 0 | 6 |
| 2024 | 0 | — | 0 | 5 |
| 2025 | 0 | — | 0 | 0 |
| 2026 | 0 | — | 0 | — |
What is it indicated for?
The Cook®Fiber Optic Bundle and Flexor® Deflecting Access Sheath are intended for use during cystoscopic, nephroscopic, laparoscopic and ureteroscopic procedures. The Cook® Fiber Optic Bundle is intended for direct visualization of body cavities or organs. The Flexor® Deflecting Access Sheath is used to provide access as well as protection for the Cook® Fiber Optic Bundle and has a second working channel for passage of additional instrumentation.
Indications for use as stated in the FDA summary.
https://510kreport.com/device/K072521 · printed Nov 6, 2026
Cite this page
510(k) Report. “K072521: Cook Fiber Optic Bundle and Flexor Deflecting Access Sheath.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K072521
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026