Twin-Pass Otw Catheter, Model 5201

K072618510(k) TraditionalCleared Nov 21, 200765-day reviewClass II21 CFR 870.1250

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Vascular Solutions, Inc. · DQY Catheter, Percutaneous

Cleared on Nov 21, 2007 as substantially equivalent to K052257 (Vascular Solutions, Inc., 2005) and 1 other predicate after a 65-day review. Its family tree reaches back 1 generation to 2005. 2 of the 13 devices in its family, counting itself, have a Class I recall. 10 later devices descend from it.

Decided
Nov 21, 2007
Review
65 days
Class
Class II
Product code
DQY
Recalls
None
Predicates
2

Its longest line of descent runs back 1 generation to K052257 (2005). 2 ancestors in all. 10 later devices descend from it, 2 citing it directly. 2 of the 13 devices in this family, counting this one, have a Class I recall.

Other ancestors, by year clearedDescendants, by year cleared 2006: 1 other ancestor, 1 with a Class I recall12012: 1 descendant cleared2018: 1 descendant cleared2014: 1 descendant cleared2016: 4 descendants cleared2015: 1 descendant cleared2017: 2 descendants clearedK052257 · Vascular Solutions Twin-Pass Dual Access Catheter · Vascular Solutions, Inc. · 2005 · Class I recall20052010201520202025
Other ancestors, by generationDescendants, by generation 1 generation back: 1 other ancestor, 1 with a Class I recall1 1 generation forward: 2 descendants2 generations forward: 3 descendants3 generations forward: 3 descendants4 generations forward: 1 descendant5 generations forward: 1 descendant K052257 · Vascular Solutions Twin-Pass Dual Access Catheter · Vascular Solutions, Inc. · 2005 · Class I recall0+5
  1. Root · 1 generation backK052257 Vascular Solutions Twin-Pass Dual Access CatheterVascular Solutions, Inc. · 2005 · Recalled (Class I)
  2. This deviceK072618 Twin-Pass Otw Catheter, Model 5201Vascular Solutions, Inc. · 2007
  3. Descendant · cites it directly · 8 of its ownK121763 Multicross Support CatheterRoxwood Medical, Inc. · 2012
  4. Descendant · 2 generations on · 3 of its ownK140910 Centercross CatheterRoxwood Medical, Inc. · 2014
  5. Descendant · 3 generations on · 2 of its ownK152456 CenterCross Ultra CatheterRoxwood Medical, Inc. · 2016
  6. Descendant · 2 generations on · 2 of its ownK143608 NovaCross MicrocatheterNitiloop, Ltd. · 2015
  7. Descendant · 4 generations on · 1 of its ownK160681 CenterCross Ultra CatheterRoxwood Medical, Inc. · 2016

Showing 5 of 10 descendants. See all descendants

Descendants cleared per year

2012: 12014: 12015: 12016: 42017: 22018: 1
2012high 4 (2016) · low 0 (2013)2026

Class I recalls in this family

Most influential descendants

Showing 5 of 10 · See all
  • K121763Multicross Support CatheterRoxwood Medical, Inc. · 2012 · cites it directly8descendants
  • K140910Centercross CatheterRoxwood Medical, Inc. · 2014 · 2 generations on3descendants
  • K152456CenterCross Ultra CatheterRoxwood Medical, Inc. · 2016 · 3 generations on2descendants
  • K143608NovaCross MicrocatheterNitiloop, Ltd. · 2015 · 2 generations on2descendants
  • K160681CenterCross Ultra CatheterRoxwood Medical, Inc. · 2016 · 4 generations on1descendant
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−1K052257Vascular Solutions Twin-Pass Dual Access CatheterVascular Solutions, Inc.2005Class I
0 (this device)K072618Twin-Pass Otw Catheter, Model 5201Vascular Solutions, Inc.2007—
+1K121763Multicross Support CatheterRoxwood Medical, Inc.2012—
+2K140910Centercross CatheterRoxwood Medical, Inc.2014—
+3K152456CenterCross Ultra CatheterRoxwood Medical, Inc.2016—
+2K143608NovaCross MicrocatheterNitiloop, Ltd.2015—
+4K160681CenterCross Ultra CatheterRoxwood Medical, Inc.2016—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
200611

Descendants by year cleared

Year clearedDevicesWith a Class I recall
201210
201410
201510
201640
201720
201810
FIG. 1 — Lineage of K072618, 2005–2018Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

2 devices in this family have a Class I recall. A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new DQY device

  1. #1 K234115 APRO 55 Catheterscore 17.5 · 6 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (2)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K052257Vascular Solutions Twin-Pass Dual Access Catheter
Summary page 1
…eous Catheter Classification Name: Unclassified Product Code: DQY Regulation: 21 CFR 870.1250 Predicate Device(s) Twin-PasSTm Dual Access Catheter (K052257) Twin-PasSTm Dual Access Catheter (K0603:27) Device Description The Vascular Solutions Twin-Pass OTW Catheter is a sterile singl…
Vascular Solutions, Inc.2005Class I
*K060327Vascular Solutions Twin-Pass Dual Access Catheter and Skyway Support Catheter
Summary page 2
…verification of the Twin-Pass OTW Catheter along with biocompatibility assessments. Shelf life testing was leveraged from the Twin Pass Dual Access Catheter (K052257 and K060327). The results of this testing confirmed the suitability of the Twin-Pass OTW Catheter for its intended use. Each bench test that…
Vascular Solutions, Inc.2006Class I

Also cleared against K052257: 1 other device →

What descends from it? (10)

2 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K121763Multicross Support CatheterRoxwood Medical, Inc.20128
K180919GORE Tri-Lumen CatheterW. L. Gore and Associates, Inc.20180

Has anything in its family been recalled? (2 Class I)

No FDA recall names this device.

Relatives with a Class I recall

Class I is FDA’s most serious recall class. A recall in the family tree is context for this device, not evidence about it.

  • K060327Vascular Solutions Twin-Pass Dual Access Catheter and Skyway Support CatheterVascular Solutions, Inc. · 2006 · Direct predicate · ◆ in the 2006 ancestors bar of FIG. 11 Class I recall
  • K052257Vascular Solutions Twin-Pass Dual Access CatheterVascular Solutions, Inc. · 2005 · Direct predicate · ◆ on the line of descent in FIG. 11 Class I recall

What does this lineage say?

  • 2 of the 2 ancestors have a recall of any class; 2 have a Class I recall.
  • Of its descendants, K121763 (Roxwood Medical, Inc., 2012) has gone furthest, with 8 descendants of its own.
  • 1 other device also cites its predicate K052257.

How does its category compare?

All DQY devices

DQY Catheter, Percutaneous: FDA decisions, review times, recalls and adverse event reports over 20 years. 2007, this device’s year, is highlighted.

FDA decisions per year · DQY

21in 2025

2007: 162008: 312009: 372010: 222011: 362012: 302013: 322014: 192015: 272016: 222017: 262018: 252019: 302020: 202021: 182022: 182023: 182024: 162025: 212026 (partial year): 11
2007high 37 (2009) · low 16 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · DQY

115in 2025

2007: 85 days median2008: 66 days median2009: 73 days median2010: 74 days median2011: 71 days median2012: 87 days median2013: 92 days median2014: 127 days median2015: 118 days median2016: 117 days median2017: 113 days median2018: 106 days median2019: 111 days median2020: 120 days median2021: 81 days median2022: 74 days median2023: 114 days median2024: 87 days median2025: 115 days median2026 (partial year): 30 days median
2007high 127 (2014) · low 66 (2008)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · DQY

1in 2025

2007: 62008: 122009: 172010: 322011: 62012: 22013: 36, 1 Class I2014: 32015: 32016: 22, 7 Class I2017: 82018: 22019: 12020: 22021: 22023: 172024: 12025: 1, 1 Class I2026 (partial year): 2, 1 Class I
2007high 36 (2013) · low 0 (2022)2026

Class I (10 since 2007) Class II/III not classified

Adverse event reports per year · DQY

3,056in 2025

2007: 3132008: 4962009: 8192010: 1,2932011: 1,2112012: 1,1912013: 1,3522014: 1,4972015: 2,3372016: 2,2522017: 2,4892018: 2,8552019: 2,9022020: 2,8892021: 3,0062022: 2,6432023: 3,0492024: 3,1902025: 3,056
2007high 3,190 (2024) · low 313 (2007)2025

MAUDE reports naming product code DQY, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
200716856313
2008316612496
2009377317819
20102274321,293
2011367161,211
2012308721,191
2013329236 (1)1,352
20141912731,497
20152711832,337
20162211722 (7)2,252
20172611382,489
20182510622,855
20193011112,902
20202012022,889
2021188123,006
2022187402,643
202318114173,049
2024168713,190
2025211151 (1)3,056
202611302 (1)—

What is it indicated for?

The TwinPass OTW Catheter is to be used in conjunction with steerable guidewires in order to access discrete regions of the coronary and peripheral arterial vasculature, to facilitate placement of guidewires and other interventional devices, for use during two guidewire procedures and to subselectively infuse/deliver diagnostic or therapeutic agents.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K072618: Twin-Pass Otw Catheter, Model 5201.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 5, 2026. https://510kreport.com/device/K072618

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.