510(k) Report

510(k) · Cleared

Recalled · Class II · 2020

Triage Total Controls 5, Triage Total Calibration Verification 5

K072892510(k) TraditionalCleared Dec 7, 200758-day reviewClass I21 CFR 862.1660Recalls 5

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Biosite Incorporated · JJY Multi-Analyte Controls, All Kinds (Assayed)

Cleared on Dec 7, 2007 as substantially equivalent to K040459 (Biosite Incorporated, 2004) after a 58-day review. Its family tree reaches back 3 generations to 1998. 1 later device descends from it. It has been recalled 5 times.

Decided
Dec 7, 2007
Review
58 days
Class
Class I
Product code
JJY
Recalls
5
Predicates
1

Its longest line of descent runs back 3 generations to K974827 (1998). 7 ancestors in all, the oldest K974461 (1997). 1 later device descends from it, 1 citing it directly.

  1. Root · 3 generations backK974827 Triage (R) Cardiac Panel Calibration Verification Controls, Triag…Biosite Incorporated · 1998
  2. 2 generations backK030088 Triage Cardiac Calibration Verification Controls, Triage Cardio…Biosite Incorporated · 2003
  3. 1 generation backK040459 Triage Profiler S.O.B. Controls and S.O.B. Calibration Verification…Biosite Incorporated · 2004
  4. This deviceK072892 Triage Total Controls 5, Triage Total Calibration Verification 5Biosite Incorporated · 2007
  5. Descendant · cites it directly · 0 of its ownK093032 Triage Total 3 Controls and Calibration Verification SetBiosite Incorporated · 2009

Most influential descendants

Showing 1 of 1 · See all
  • K093032Triage Total 3 Controls and Calibration Verification SetBiosite Incorporated · 2009 · cites it directly0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−3K974827Triage (R) Cardiac Panel Calibration Verification Controls, Triag (R)…Biosite Incorporated1998—
−2K030088Triage Cardiac Calibration Verification Controls, Triage Cardio Profiler…Biosite Incorporated2003—
−1K040459Triage Profiler S.O.B. Controls and S.O.B. Calibration Verification ControlsBiosite Incorporated2004—
0 (this device)K072892Triage Total Controls 5, Triage Total Calibration Verification 5Biosite Incorporated2007—
+1K093032Triage Total 3 Controls and Calibration Verification SetBiosite Incorporated2009—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199710
200020
200310

Descendants by year cleared

Year clearedDevicesWith a Class I recall
200910
FIG. 1 — Lineage of K072892, 1998–2009Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in JJY? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

  • Candidate predicates for a device like this, rankedin the report
  • Recall history across each candidate’s familyin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K040459Triage Profiler S.O.B. Controls and S.O.B. Calibration Verification Controls
Summary page 1
…Quality Control Material (Assayed and Unassayed) Product Code: JJY 3. Predicate Devices K040459 - Triage® Profiler S.OB. (Shortness of Breath) Controls and the Triage® Profiler S.O.B. Calibration Verification Controls…
Biosite Incorporated2004—

What descends from it? (1)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K093032Triage Total 3 Controls and Calibration Verification SetBiosite Incorporated20090

Has anything in its family been recalled? (0 Class I)

Recalls of this device

DateClassRecallRoot causeReason
Jul 28, 2020Class IIZ-3054-2020Process controlProduct was shipped with refrigeration (ice) instead of frozen (dry ice).
Oct 12, 2016Class IIZ-0588-2017Employee errorEncoded with incorrect ranges that are not consistent with the ranges printed on the Expected Value Card.
Feb 6, 2009Not classifiedZ-1790-2010OtherIncidence of low recovery results has exceeded post market surveillance thresholds of customer complaints in the field.
Feb 6, 2009Not classifiedZ-1789-2010OtherIncidence of low recovery results has exceeded post market surveillance thresholds of customer complaints in the field.
Feb 6, 2009Not classifiedZ-1788-2010OtherIncidence of low recovery results has exceeded post market surveillance thresholds of customer complaints in the field.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 9 years and passes through 1 company; a new generation was cleared every 3.4 years on median.
  • None of the 7 ancestors has a recall.
  • Of its descendants, K093032 (Biosite Incorporated, 2009) has gone furthest, with 0 descendants of its own.

How does its category compare?

All JJY devices

JJY Multi-Analyte Controls, All Kinds (Assayed): FDA decisions, review times, recalls and adverse event reports over 20 years. 2007, this device’s year, is highlighted.

FDA decisions per year · JJY

3in 2017

2007: 112008: 72009: 82010: 102011: 142012: 132013: 162014: 102015: 42016: 12017: 3
2007high 16 (2013) · low 0 (2018)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · JJY

78in 2017

2007: 49 days median2008: 54 days median2009: 80 days median2010: 109 days median2011: 120 days median2012: 40 days median2013: 82 days median2014: 49 days median2015: 153 days median2017: 78 days median
2007high 153 (2015) · low 40 (2012)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · JJY

2in 2025

2007: 52009: 22010: 62011: 12012: 32013: 22014: 22015: 12016: 32017: 42018: 32019: 42020: 62022: 32023: 32025: 22026 (partial year): 1
2007high 6 (2010) · low 0 (2008)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · JJY

13in 2025

2007: 22008: 12009: 32010: 32011: 62012: 202013: 52014: 42015: 42016: 132017: 122018: 72019: 12020: 72021: 12023: 42024: 12025: 13
2007high 20 (2012) · low 0 (2022)2025

MAUDE reports naming product code JJY, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
2007114952
200875401
200988023
20101010963
20111412016
20121340320
2013168225
2014104924
2015415314
20161—313
2017378412
20180—37
20190—41
20200—67
20210—01
20220—30
20230—34
20240—01
20250—213
20260—1—

What is it indicated for?

The Triage Total Controls 5 are assayed materials to be used with the Triage® Profiler S.O.B. TM Panel, Triage CardioProfilER® Panel, Triage Cardiac Panel, Triage BNP Test, Triage D-Dimer Test and the Triage Meters to assist in monitoring test performance.

The Triage Total Calibration Verification 5 materials are to be used with the Triage Profiler S.O.B. TM Panel, Triage CardioProfilER® Panel, Triage Cardiac Panel, Triage BNP Test, Triage D-Dimer Test and the Triage Meters to verify the calibration of the Test Devices throughout the measurable range.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K072892: Triage Total Controls 5, Triage Total Calibration Verification 5.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K072892

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026