510(k) · Cleared
ClearedClareblend Led Probes Model# 7201-415, 7204-631, 7205-830
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Clareblend, Inc. · GEX Powered Laser Surgical Instrument
Cleared on Oct 1, 2008 as substantially equivalent to K030883 (Photo Therapeutics Limited, 2003) and 2 other predicates after a 341-day review. Its family tree reaches back 9 generations to 1995.
- Decided
- Oct 1, 2008
- Review
- 341 days
- Class
- Class II
- Product code
- GEX
- Recalls
- None
- Predicates
- 3
Its longest line of descent runs back 9 generations to K943450 (1995). 91 ancestors in all, the oldest K800617 (1980). No later device cites it as a predicate yet.
- Root · 9 generations backK943450 Arthrocare Arthroscopic Electrosurgery System Model 970Arthrocare Corp. · 1995
- 5 generations between
- 3 generations backK982816 Vnus Closure SystemVnus Medical Technologies, Inc. · 1999
- 2 generations backK022266 Aurora SRSyneron Medical, Ltd. · 2002
- 1 generation backK030426 Omnilux RedPhoto Therapeutics Limited · 2003
- This deviceK073022 Clareblend Led Probes Model# 7201-415, 7204-631, 7205-830Clareblend, Inc. · 2008
Show all 9 generations
- Root · 9 generations backK943450 Arthrocare Arthroscopic Electrosurgery System Model 970Arthrocare Corp. · 1995
- 8 generations backK961069 Arthrocare Urologic Multi-Electrode Electrosurgery SystemArthrocare Corp. · 1996
- 7 generations backK962445 Arthrocare Dental Electrosurgery SystemArthrocare Corp. · 1996
- 6 generations backK964849 Arthrocare Dermatologic Electrosurgery SystemArthrocare Corp. · 1997
- 5 generations backK971532 Arthrocare Electrosurgery SystemArthrocare Corp. · 1997
- 4 generations backK974521 Vnus Closure SystemVnus Medical Technologies, Inc. · 1998
- 3 generations backK982816 Vnus Closure SystemVnus Medical Technologies, Inc. · 1999
- 2 generations backK022266 Aurora SRSyneron Medical, Ltd. · 2002
- 1 generation backK030426 Omnilux RedPhoto Therapeutics Limited · 2003
- This deviceK073022 Clareblend Led Probes Model# 7201-415, 7204-631, 7205-830Clareblend, Inc. · 2008
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −9 | K943450 | Arthrocare Arthroscopic Electrosurgery System Model 970 | Arthrocare Corp. | 1995 | — |
| −8 | K961069 | Arthrocare Urologic Multi-Electrode Electrosurgery System | Arthrocare Corp. | 1996 | — |
| −7 | K962445 | Arthrocare Dental Electrosurgery System | Arthrocare Corp. | 1996 | — |
| −6 | K964849 | Arthrocare Dermatologic Electrosurgery System | Arthrocare Corp. | 1997 | — |
| −5 | K971532 | Arthrocare Electrosurgery System | Arthrocare Corp. | 1997 | — |
| −4 | K974521 | Vnus Closure System | Vnus Medical Technologies, Inc. | 1998 | — |
| −3 | K982816 | Vnus Closure System | Vnus Medical Technologies, Inc. | 1999 | — |
| −2 | K022266 | Aurora SR | Syneron Medical, Ltd. | 2002 | — |
| −1 | K030426 | Omnilux Red | Photo Therapeutics Limited | 2003 | — |
| 0 (this device) | K073022 | Clareblend Led Probes Model# 7201-415, 7204-631, 7205-830 | Clareblend, Inc. | 2008 | — |
Other ancestors by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 1980 | 1 | 0 |
| 1985 | 1 | 0 |
| 1990 | 1 | 0 |
| 1991 | 3 | 0 |
| 1992 | 3 | 0 |
| 1993 | 3 | 0 |
| 1994 | 8 | 0 |
| 1995 | 9 | 0 |
| 1996 | 12 | 0 |
| 1997 | 13 | 0 |
| 1998 | 10 | 0 |
| 1999 | 4 | 0 |
| 2000 | 6 | 0 |
| 2001 | 1 | 0 |
| 2002 | 4 | 0 |
| 2003 | 2 | 0 |
| 2005 | 1 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in GEX? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new GEX device
- #1 K222064 The Alma Soprano Titaniumscore 38.1 · 24 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (3)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K030883 | Omnilux BlueSummary page 1…applicable classification name. 3. Predicate Device Clareblend LED Probes Models 7201-415, 7204-631, 7205-830 are substantially equivalent to Omnilux Blue (K030883), Omnilux Revive (K030426), Omnilux Plus (K043317) 4. Device Description The Clareblend Probes are hand held devices that… | 2003 |
| * | K030426 | Omnilux RedSummary page 1…name. 3. Predicate Device Clareblend LED Probes Models 7201-415, 7204-631, 7205-830 are substantially equivalent to Omnilux Blue (K030883), Omnilux Revive (K030426), Omnilux Plus (K043317) 4. Device Description The Clareblend Probes are hand held devices that utilizes Light Emitting D… | 2003 |
| * | K043317 | Omnilux PlusSummary page 1…evice Clareblend LED Probes Models 7201-415, 7204-631, 7205-830 are substantially equivalent to Omnilux Blue (K030883), Omnilux Revive (K030426), Omnilux Plus (K043317) 4. Device Description The Clareblend Probes are hand held devices that utilizes Light Emitting Diodes to provide LED lig… | 2005 |
What descends from it?
No later submission names this one as a predicate yet.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- The line of descent spans 13 years and passes through 5 companies; a new generation was cleared every 9 months on median.
- 3 of the 91 ancestors have a recall of any class.
- 15 other devices also cite its predicate K030883.
How does its category compare?
All GEX devicesGEX Powered Laser Surgical Instrument: FDA decisions, review times, recalls and adverse event reports over 20 years. 2008, this device’s year, is highlighted.
FDA decisions per year · GEX
83in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · GEX
90in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · GEX
3in 2024
Class I (1 since 2007) Class II/III not classified
Adverse event reports per year · GEX
2,720in 2025
MAUDE reports naming product code GEX, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 73 | 79 | 9 | 342 |
| 2008 | 107 | 86 | 2 | 232 |
| 2009 | 69 | 100 | 0 | 209 |
| 2010 | 50 | 96 | 4 | 1,711 |
| 2011 | 41 | 83 | 18 | 3,024 |
| 2012 | 45 | 118 | 5 | 2,000 |
| 2013 | 46 | 144 | 3 | 2,236 |
| 2014 | 61 | 147 | 6 | 2,036 |
| 2015 | 47 | 112 | 0 | 2,099 |
| 2016 | 51 | 114 | 1 | 2,585 |
| 2017 | 67 | 90 | 5 (1) | 2,977 |
| 2018 | 51 | 78 | 5 | 3,525 |
| 2019 | 41 | 88 | 6 | 2,709 |
| 2020 | 52 | 90 | 1 | 2,183 |
| 2021 | 53 | 123 | 0 | 3,465 |
| 2022 | 60 | 152 | 0 | 2,288 |
| 2023 | 52 | 87 | 6 | 2,337 |
| 2024 | 82 | 90 | 3 | 2,187 |
| 2025 | 83 | 90 | 0 | 2,720 |
| 2026 | 57 | 90 | 2 | — |
What is it indicated for?
The Clareblend Probes are intended to provide light to the body.
Clareblend Probe (Red-63 1) is generally indicated for the treatment of superficial, benign vascular and pigmented lesions
Clareblend Probe (Blue-415) is generally indicated for the treatment of dermatological conditions and specially indicated for the treatment of mild to moderate inflammatory acne vulgaris.
Clareblend Probe (IR-830) is generally indicated for the temporary relief of minor muscle and joint pain, arthritis and muscle spasm, relieving stiffness; promoting the relaxation of muscle tissue; and to temporarily increase local blood circulation where applied.
Indications for use as stated in the FDA summary.
https://510kreport.com/device/K073022 · printed Nov 4, 2026
Cite this page
510(k) Report. “K073022: Clareblend Led Probes Model# 7201-415, 7204-631, 7205-830.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K073022
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026