510(k) · Cleared
ClearedAnkylos Dental Implant System/Claims
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Dentsply International, Inc. · DZE Implant, Endosseous, Root-Form
Cleared on Feb 15, 2008 as substantially equivalent to K041509 (Friadent GmbH, 2004) after a 108-day review. Its family tree reaches back 7 generations to 1990.
- Decided
- Feb 15, 2008
- Review
- 108 days
- Class
- Class II
- Product code
- DZE
- Recalls
- None
- Predicates
- 1
Its longest line of descent runs back 7 generations to K894595 (1990). 17 ancestors in all. No later device cites it as a predicate yet.
- Root · 7 generations backK894595 Bonefit R Screw ImplantsInstitut Straumann AG · 1990
- 6 generations backK984104 Iti Dental Implant SystemStraumann USA · 1999 · Recalled
- 5 generations backK992937 Dental ImplantNobel Biocare Uas, Inc. · 2000 · Recalled
- 4 generations backK013067 Frialoc Dental Implant SystemFriadent GmbH · 2002
- 3 generations backK021318 Xive Dental Implant SystemFriadent GmbH · 2002
- 2 generations backK032158 Xive Dental Implant System MultipleFriadent GmbH · 2003
- 1 generation backK041509 Ankylos Dental Implant SystemFriadent GmbH · 2004
- This deviceK073067 Ankylos Dental Implant System/ClaimsDentsply International, Inc. · 2008
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −7 | K894595 | Bonefit R Screw Implants | Institut Straumann AG | 1990 | — |
| −6 | K984104 | Iti Dental Implant System | Straumann USA | 1999 | 1 |
| −5 | K992937 | Dental Implant | Nobel Biocare Uas, Inc. | 2000 | 1 |
| −4 | K013067 | Frialoc Dental Implant System | Friadent GmbH | 2002 | — |
| −3 | K021318 | Xive Dental Implant System | Friadent GmbH | 2002 | — |
| −2 | K032158 | Xive Dental Implant System Multiple | Friadent GmbH | 2003 | — |
| −1 | K041509 | Ankylos Dental Implant System | Friadent GmbH | 2004 | — |
| 0 (this device) | K073067 | Ankylos Dental Implant System/Claims | Dentsply International, Inc. | 2008 | — |
Other ancestors by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 1993 | 2 | 0 |
| 1994 | 2 | 0 |
| 1996 | 3 | 0 |
| 1997 | 1 | 0 |
| 1998 | 1 | 0 |
| 2002 | 1 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in DZE? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new DZE device
- #1 K211090 ZENEX Implant Systemscore 25.4 · 15 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (1)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K041509 | Ankylos Dental Implant SystemSummary page 1…nt System/Claims CLASSIFICATION NAME: Endosseous dental implant (21 CFR 872.3640) PREDICATE DEVICES: ANKYLOS® Dental Implant System K041509 DEVICE DESCRIPTION: The ANKYLOS® Dental Implant System has been cleared for commercial distribution. The purpose of this appli… | 2004 |
What descends from it?
No later submission names this one as a predicate yet.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- The line of descent spans 18 years and passes through 5 companies; a new generation was cleared every 1.1 years on median.
- 2 of the 17 ancestors have a recall of any class.
- 9 other devices also cite its predicate K041509.
How does its category compare?
All DZE devicesDZE Implant, Endosseous, Root-Form: FDA decisions, review times, recalls and adverse event reports over 20 years. 2008, this device’s year, is highlighted.
FDA decisions per year · DZE
31in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · DZE
184in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · DZE
1in 2025
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · DZE
465,788in 2025
MAUDE reports naming product code DZE, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 43 | 107 | 11 | 225 |
| 2008 | 61 | 118 | 4 | 393 |
| 2009 | 41 | 110 | 3 | 164 |
| 2010 | 34 | 162 | 3 | 360 |
| 2011 | 26 | 194 | 0 | 362 |
| 2012 | 39 | 174 | 11 | 358 |
| 2013 | 42 | 195 | 1 | 391 |
| 2014 | 36 | 265 | 7 | 1,124 |
| 2015 | 36 | 215 | 3 | 2,894 |
| 2016 | 40 | 219 | 15 | 1,116 |
| 2017 | 48 | 223 | 4 | 9,719 |
| 2018 | 41 | 200 | 4 | 12,892 |
| 2019 | 31 | 231 | 8 | 167,016 |
| 2020 | 41 | 230 | 0 | 255,524 |
| 2021 | 34 | 182 | 6 | 479,618 |
| 2022 | 34 | 243 | 0 | 483,224 |
| 2023 | 35 | 248 | 0 | 537,585 |
| 2024 | 40 | 222 | 1 | 473,629 |
| 2025 | 31 | 184 | 1 | 465,788 |
| 2026 | 15 | 194 | 2 | — |
What is it indicated for?
The ANKYLOS® Dental Implant System is indicated for surgical placement in the upper and lower jaw arches, to provide a root form means for single or multiple unit prosthetic appliance attachment to restore a patient's chewing function. Implants can be placed with a conventional 2 stage surgical process with an option for transmucosal healing or they can be placed in a single stage surgical process for immediate loading. Immediate loading is restricted to the anterior mandible, based on 4 interforminal placed implants, and not indicated for single, unsplinted implants. Patients must be subject for dental treatment with endosseus implant.
Indications for use as stated in the FDA summary.
https://510kreport.com/device/K073067 · printed Nov 4, 2026
Cite this page
510(k) Report. “K073067: Ankylos Dental Implant System/Claims.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K073067
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026