510(k) Report

510(k) · Cleared

Cleared

Collimare Collimator Family

K073124510(k) AbbreviatedCleared Nov 16, 200710-day reviewClass II21 CFR 892.1610

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Collimare, LLC · IZW Collimator, Automatic, Radiographic

Cleared on Nov 16, 2007 as substantially equivalent to K810598 (Midmark Corp., 1981) and 1 other predicate after a 10-day review. Its family tree reaches back 1 generation to 1981.

Decided
Nov 16, 2007
Review
10 days
Class
Class II
Product code
IZW
Recalls
None
Predicates
2

Its longest line of descent runs back 1 generation to K810598 (1981). 2 ancestors in all. No later device cites it as a predicate yet.

Other ancestors, by year cleared 1997: 1 other ancestorK810598 · X-Ray Collimating Devices · Midmark Corp. · 1981198019851990199520002005
Other ancestors, by generation 1 generation back: 1 other ancestor K810598 · X-Ray Collimating Devices · Midmark Corp. · 19810
  1. Root · 1 generation backK810598 X-Ray Collimating DevicesMidmark Corp. · 1981
  2. This deviceK073124 Collimare Collimator FamilyCollimare, LLC · 2007
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−1K810598X-Ray Collimating DevicesMidmark Corp.1981—
0 (this device)K073124Collimare Collimator FamilyCollimare, LLC2007—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199710
FIG. 1 — Lineage of K073124, 1981–2007Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in IZW? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

  • Candidate predicates for a device like this, rankedin the report
  • Recall history across each candidate’s familyin the report
Get a 510(k) Report

What was it cleared against? (2)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K810598X-Ray Collimating Devices
Summary page 1
…Device Classification Regulation Number: IZX & IZW Classification CommitteelPanel: Radiology Predicate Devices: X-Ray Collimating Devices K81 0598 Manufactured by Eureka X-Ray Tube AXT150OMC K97…
Midmark Corp.1981—
*K972966Axt 150M Manual Collimator (Axt 150M)
Summary page 1
…X-Ray Collimating Devices K81 0598 Manufactured by Eureka X-Ray Tube AXT150OMC K972966 Manufactured by Applied X-Ray Technologies Description: The Collimare "Collimator Famil…
Applied X-Ray Technologies, Inc.1997—

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • None of the 2 ancestors has a recall.

How does its category compare?

All IZW devices

IZW Collimator, Automatic, Radiographic: FDA decisions, review times, recalls and adverse event reports over 20 years. 2007, this device’s year, is highlighted.

FDA decisions per year · IZW

2in 2010

2007: 22008: 12009: 22010: 2
2007high 2 (2007) · low 0 (2011)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · IZW

Too few IZW 510(k)s in any year since 2007 to give a median.

Recalls per year · IZW

1in 2011

2007: 12008: 12011: 1
2007high 1 (2007) · low 0 (2009)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · IZW

1in 2024

2007: 22010: 12011: 12014: 12024: 1
2007high 2 (2007) · low 0 (2008)2025

MAUDE reports naming product code IZW, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20072—12
20081—10
20092—00
20102—01
20110—11
20120—00
20130—00
20140—01
20150—00
20160—00
20170—00
20180—00
20190—00
20200—00
20210—00
20220—00
20230—00
20240—01
20250—00
20260—0—

What is it indicated for?

The Collimare "Collimator Family" and/or variations is used to control the x-ray beam for use on diagnostic imaging equipment during radiographic and fluoroscopic procedures. It is designed to be adapted to various x-ray systems.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K073124: Collimare Collimator Family.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K073124

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026