510(k) Report

510(k) · Cleared

Cleared

Modification to:Specialty Needles

K073222510(k) SpecialCleared Apr 9, 2008146-day reviewClass II21 CFR 868.5150

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Busse Hospital Disposables, Inc. · BSP Needle, Conduction, Anesthetic (W/Wo Introducer)

Cleared on Apr 9, 2008 as substantially equivalent to K061394 (Busse Hospital Disposables, Inc., 2006) after a 146-day review. Its family tree reaches back 2 generations to 1990.

Decided
Apr 9, 2008
Review
146 days
Class
Class II
Product code
BSP
Recalls
None
Predicates
1

Its longest line of descent runs back 2 generations to K895771 (1990). No later device cites it as a predicate yet.

  1. Root · 2 generations backK895771 Exel Spinal NeedlesExel Intl. · 1990
  2. 1 generation backK061394 Specialty Needles (Spinal Needle, Pencil Point Spinal Needle…Busse Hospital Disposables, Inc. · 2006
  3. This deviceK073222 Modification to:Specialty NeedlesBusse Hospital Disposables, Inc. · 2008
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−2K895771Exel Spinal NeedlesExel Intl.1990—
−1K061394Specialty Needles (Spinal Needle, Pencil Point Spinal Needle, Epidural Needle)Busse Hospital Disposables, Inc.2006—
0 (this device)K073222Modification to:Specialty NeedlesBusse Hospital Disposables, Inc.2008—
FIG. 1 — Lineage of K073222, 1990–2008Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in BSP? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new BSP device

  1. #1 K241954 SonoBlock; SonoBlock IIscore 11.0 · 1 generation · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K061394Specialty Needles (Spinal Needle, Pencil Point Spinal Needle, Epidural Needle)
Summary page 1
…ification: Class II, 21 CFR 868.5150 Product Code: BSP Predicate Device: Busse Spinal Needle - (K061394) Device Description: Anesthesia conduction needles consist of different…
Busse Hospital Disposables, Inc.2006—

Also cleared against K061394: 1 other device →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 18 years and passes through 2 companies; a new generation was cleared every 16.6 years on median.
  • None of the 2 ancestors has a recall.
  • 1 other device also cites its predicate K061394.

How does its category compare?

All BSP devices

BSP Needle, Conduction, Anesthetic (W/Wo Introducer): FDA decisions, review times, recalls and adverse event reports over 20 years. 2008, this device’s year, is highlighted.

FDA decisions per year · BSP

4in 2025

2007: 32008: 82009: 52010: 32011: 32012: 32013: 22014: 22015: 22016: 62017: 42018: 82019: 22020: 32021: 32022: 22024: 32025: 4
2007high 8 (2008) · low 0 (2023)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · BSP

170in 2025

2007: 189 days median2008: 127 days median2009: 97 days median2010: 79 days median2011: 114 days median2012: 148 days median2016: 268 days median2017: 186 days median2018: 241 days median2020: 269 days median2021: 265 days median2024: 70 days median2025: 170 days median
2007high 269 (2020) · low 70 (2024)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · BSP

1in 2020

2016: 12019: 12020: 12026 (partial year): 1, 1 Class I
2007high 1 (2016) · low 0 (2007)2026

Class I (1 since 2007) Class II/III not classified

Adverse event reports per year · BSP

86in 2025

2007: 262008: 242009: 302010: 492011: 332012: 202013: 322014: 412015: 382016: 1522017: 342018: 692019: 862020: 782021: 522022: 842023: 752024: 662025: 86
2007high 152 (2016) · low 20 (2012)2025

MAUDE reports naming product code BSP, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20073189026
20088127024
2009597030
2010379049
20113114033
20123148020
20132—032
20142—041
20152—038
201662681152
20174186034
20188241069
20192—186
20203269178
20213265052
20222—084
20230—075
2024370066
20254170086
20260—1 (1)—

What is it indicated for?

specialty needles - Spinal Needle, Pencil Point Needle, and Epidural Needle - are intended for the transient delivery of anesthetics to provide regional anesthesia or to facilitate placement of an epidural catheter.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K073222: Modification to:Specialty Needles.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K073222

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026