510(k) · Cleared
ClearedNuvasive Helix Mini Acp System
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Nuvasive, Inc. · KWQ Appliance, Fixation, Spinal Intervertebral Body
Cleared on Jan 29, 2008 after a 69-day review. The FDA summary names its predicate without a number. 24 later devices descend from it.
- Decided
- Jan 29, 2008
- Review
- 69 days
- Class
- Class II
- Product code
- KWQ
- Recalls
- None
- Predicates
- 0
24 later devices descend from it, 7 citing it directly.
- This deviceK073275 Nuvasive Helix Mini Acp SystemNuvasive, Inc. · 2008
- Descendant · cites it directly · 15 of its ownK121060 Spine Frontier Indus Acp SystemSpinefrontier, Inc. · 2012 · Recalled
- Descendant · 2 generations on · 6 of its ownK153526 Pyrenees Cervical Plate SystemK2m · 2016
- Descendant · 2 generations on · 6 of its ownK140234 Aspiron Acp SystemU&I Corp. · 2014
- Descendant · 3 generations on · 5 of its ownK162664 Pyrenees Cervical Plate SystemK2m, Inc. · 2016
- Descendant · cites it directly · 4 of its ownK191500 NuVasive® ACP SystemNu Vasive, Incorporated · 2019
Showing 5 of 24 descendants. See all descendants
Descendants cleared per year
Most influential descendants
Showing 5 of 24 · See all- K121060Spine Frontier Indus Acp SystemSpinefrontier, Inc. · 2012 · cites it directly15descendants
- K153526Pyrenees Cervical Plate SystemK2m · 2016 · 2 generations on6descendants
- K140234Aspiron Acp SystemU&I Corp. · 2014 · 2 generations on6descendants
- K162664Pyrenees Cervical Plate SystemK2m, Inc. · 2016 · 3 generations on5descendants
- K191500NuVasive® ACP SystemNu Vasive, Incorporated · 2019 · cites it directly4descendants
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| 0 (this device) | K073275 | Nuvasive Helix Mini Acp System | Nuvasive, Inc. | 2008 | — |
| +1 | K121060 | Spine Frontier Indus Acp System | Spinefrontier, Inc. | 2012 | 6 |
| +2 | K153526 | Pyrenees Cervical Plate System | K2m | 2016 | — |
| +2 | K140234 | Aspiron Acp System | U&I Corp. | 2014 | — |
| +3 | K162664 | Pyrenees Cervical Plate System | K2m, Inc. | 2016 | — |
| +1 | K191500 | NuVasive® ACP System | Nu Vasive, Incorporated | 2019 | — |
Descendants by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 2011 | 1 | 0 |
| 2012 | 1 | 0 |
| 2014 | 1 | 0 |
| 2016 | 2 | 0 |
| 2018 | 2 | 0 |
| 2019 | 3 | 0 |
| 2020 | 2 | 0 |
| 2021 | 1 | 0 |
| 2022 | 2 | 0 |
| 2023 | 2 | 0 |
| 2024 | 3 | 0 |
| 2025 | 3 | 0 |
| 2026 | 1 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in KWQ? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new KWQ device
- #1 K233640 Segmental Plating System (SPS);IdentiTi SPS…score 21.9 · 31 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (1)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | — | HELIX ACP System Named without a submission number |
What descends from it? (24)
See all 247 later devices cite it directly; ranked here by how many devices descend from each in turn.
| Number | Device | Decided | Descendants |
|---|---|---|---|
| K121060 | Spine Frontier Indus Acp System | 2012 | 15 |
| K191500 | NuVasive® ACP System | 2019 | 4 |
| K201078 | NuVasive® ACP System | 2020 | 3 |
| K203253 | NuVasive ACP System | 2020 | 2 |
| K212446 | NuVasive Anterior Cervical Plate Systems | 2021 | 1 |
| K103423 | Mis Anterior Cervical Plating System | 2011 | 1 |
| K190170 | MVP Cervical Plate System | 2019 | 0 |
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- Of its descendants, K121060 (Spinefrontier, Inc., 2012) has gone furthest, with 15 descendants of its own.
How does its category compare?
All KWQ devicesKWQ Appliance, Fixation, Spinal Intervertebral Body: FDA decisions, review times, recalls and adverse event reports over 20 years. 2008, this device’s year, is highlighted.
FDA decisions per year · KWQ
7in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · KWQ
64in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · KWQ
1in 2018
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · KWQ
248in 2025
MAUDE reports naming product code KWQ, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 27 | 101 | 2 | 288 |
| 2008 | 32 | 70 | 33 | 348 |
| 2009 | 23 | 90 | 35 | 355 |
| 2010 | 23 | 104 | 2 | 691 |
| 2011 | 22 | 95 | 5 | 415 |
| 2012 | 26 | 90 | 7 | 544 |
| 2013 | 22 | 88 | 6 | 796 |
| 2014 | 17 | 124 | 0 | 546 |
| 2015 | 25 | 102 | 2 | 562 |
| 2016 | 15 | 121 | 9 | 502 |
| 2017 | 20 | 67 | 8 | 492 |
| 2018 | 22 | 95 | 1 | 341 |
| 2019 | 26 | 81 | 0 | 298 |
| 2020 | 26 | 55 | 0 | 400 |
| 2021 | 17 | 59 | 0 | 591 |
| 2022 | 18 | 85 | 0 | 392 |
| 2023 | 16 | 59 | 0 | 320 |
| 2024 | 17 | 64 | 0 | 419 |
| 2025 | 7 | 64 | 0 | 248 |
| 2026 | 10 | 76 | 0 | — |
What is it indicated for?
The NuVasive HELIX Mini Anterior Cervical Plating System is intended for anterior screw fixation of the cervical spine. These implants have been designed to provide stabilization as an adjunct to cervical fusion. Indications for the use of this implant system include degenerative disc disease defined as neck pain of discogenic origin with the degeneration of the disc confirmed by history and radiographic studies, spondylolisthesis, trauma, spinal…
Read the full statement (103 words)
The NuVasive HELIX Mini Anterior Cervical Plating System is intended for anterior screw fixation of the cervical spine. These implants have been designed to provide stabilization as an adjunct to cervical fusion. Indications for the use of this implant system include degenerative disc disease defined as neck pain of discogenic origin with the degeneration of the disc confirmed by history and radiographic studies, spondylolisthesis, trauma, spinal stenosis, deformity, tumor, pseudarthrosis or failed previous fusion.
WARNING: The NuVasive HELIX Mini Anterior Cervical Plating System is not intended for screw attachment or fixation to the posterior elements (pedicles) of the cervical, thoracic or lumbar spine.
Indications for use as stated in the FDA summary.
https://510kreport.com/device/K073275 · printed Nov 6, 2026
Cite this page
510(k) Report. “K073275: Nuvasive Helix Mini Acp System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K073275
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026