510(k) · Cleared
ClearedT-Quest System
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Medx, Inc. · IYX Camera, Scintillation (Gamma)
Cleared on Dec 20, 2007 as substantially equivalent to K052473 (Inter Medical Medizintechnik GmbH, 2005) after a 10-day review. Its family tree reaches back 1 generation to 2005. 1 later device descends from it.
- Decided
- Dec 20, 2007
- Review
- 10 days
- Class
- Class I
- Product code
- IYX
- Recalls
- None
- Predicates
- 1
Its longest line of descent runs back 1 generation to K052473 (2005). 1 later device descends from it, 1 citing it directly.
Most influential descendants
Showing 1 of 1 · See all- K101391Scandia-45 Gamma Camera SystemScandia Corporation · 2010 · cites it directly0descendants
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −1 | K052473 | CX 250 C Plus with Gammaxp Software, Model 0121 0000 | Inter Medical Medizintechnik GmbH | 2005 | — |
| 0 (this device) | K073456 | T-Quest System | Medx, Inc. | 2007 | — |
| +1 | K101391 | Scandia-45 Gamma Camera System | Scandia Corporation | 2010 | — |
Descendants by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 2010 | 1 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in IYX? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new IYX device
- #1 K230221 QDOSE® Multi-purpose Voxel Dosimetry…score 6.2 · 2 generations · no Class I recall
- #2 Held for the reportin the report
What was it cleared against? (1)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K052473 | CX 250 C Plus with Gammaxp Software, Model 0121 0000Summary page 1…Camera System Model CX 250 C Plus. 510(k) Number K052473. Description of Device: The T-Quest System consists of a small mobile scintillation camera, accessories such as optional phantom… | 2005 |
| † | K945792 | IM512P | 1995 |
| † | K961104 | Notebook Imager | 1997 |
What descends from it? (1)
1 later device cites it directly; ranked here by how many devices descend from each in turn.
| Number | Device | Decided | Descendants |
|---|---|---|---|
| K101391 | Scandia-45 Gamma Camera System | 2010 | 0 |
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
How does its category compare?
All IYX devicesIYX Camera, Scintillation (Gamma): FDA decisions, review times, recalls and adverse event reports over 20 years. 2007, this device’s year, is highlighted.
FDA decisions per year · IYX
2in 2023
2026 to Oct 25, outlined.
Median 510(k) review, days · IYX
82in 2011
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · IYX
2in 2025
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · IYX
1in 2022
MAUDE reports naming product code IYX, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 2 | — | 0 | 11 |
| 2008 | 2 | — | 0 | 10 |
| 2009 | 2 | — | 0 | 8 |
| 2010 | 4 | 82 | 0 | 5 |
| 2011 | 3 | 82 | 0 | 6 |
| 2012 | 0 | — | 0 | 1 |
| 2013 | 1 | — | 0 | 1 |
| 2014 | 1 | — | 0 | 3 |
| 2015 | 0 | — | 0 | 4 |
| 2016 | 2 | — | 0 | 2 |
| 2017 | 1 | — | 0 | 0 |
| 2018 | 0 | — | 0 | 1 |
| 2019 | 0 | — | 0 | 0 |
| 2020 | 0 | — | 0 | 0 |
| 2021 | 0 | — | 0 | 0 |
| 2022 | 0 | — | 0 | 1 |
| 2023 | 2 | — | 0 | 0 |
| 2024 | 0 | — | 0 | 0 |
| 2025 | 0 | — | 2 | 0 |
| 2026 | 0 | — | 0 | — |
What is it indicated for?
The intended uses of the T-Quest™ System are the acquisition, processing, display and analysis of planar images of the thyroid gland and other small organs using approved pharmaceuticals.
Indications for use as stated in the FDA summary.
https://510kreport.com/device/K073456 · printed Nov 4, 2026
Cite this page
510(k) Report. “K073456: T-Quest System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K073456
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026