510(k) · Cleared
ClearedStandard Wheelchair Platform
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Design Specific, Ltd. · INO Chair, Positioning, Electric
Cleared on Feb 6, 2009 as substantially equivalent to K071793 (Barton Medical Corp., 2007) and 1 other predicate after a 415-day review. Its family tree reaches back 3 generations to 1989. 1 later device descends from it.
- Decided
- Feb 6, 2009
- Review
- 415 days
- Class
- Class II
- Product code
- INO
- Recalls
- None
- Predicates
- 2
Its longest line of descent runs back 3 generations to K885343 (1989). 5 ancestors in all. 1 later device descends from it, 1 citing it directly.
- Root · 3 generations backK885343 StandexAlt, Inc. · 1989
- 2 generations backK062402 Easystand EvolvInvacare Corp. · 2006
- 1 generation backK071793 Convertible I-Series Positioning and Transfer ChairBarton Medical Corp. · 2007
- This deviceK073565 Standard Wheelchair PlatformDesign Specific, Ltd. · 2009
- Descendant · cites it directly · 0 of its ownK101723 Compact Wheelchair PlatformDesign Specific Fletcher · 2010
Most influential descendants
Showing 1 of 1 · See all- K101723Compact Wheelchair PlatformDesign Specific Fletcher · 2010 · cites it directly0descendants
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −3 | K885343 | Standex | Alt, Inc. | 1989 | — |
| −2 | K062402 | Easystand Evolv | Invacare Corp. | 2006 | — |
| −1 | K071793 | Convertible I-Series Positioning and Transfer Chair | Barton Medical Corp. | 2007 | — |
| 0 (this device) | K073565 | Standard Wheelchair Platform | Design Specific, Ltd. | 2009 | — |
| +1 | K101723 | Compact Wheelchair Platform | Design Specific Fletcher | 2010 | — |
Other ancestors by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 2000 | 2 | 0 |
Descendants by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 2010 | 1 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in INO? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
- Candidate predicates for a device like this, rankedin the report
- Recall history across each candidate’s familyin the report
What was it cleared against? (4)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K071793 | Convertible I-Series Positioning and Transfer ChairSummary page 2…Barton Medical Corp. 5725 Hway 290 West #103 Austin TX 78735 8701 5 10(k) No. K071793 Electronic Positioning Chair Medline Industries Inc One Med… | 2007 |
| * | K001937 | Medline Electronic Positioning ChairSummary page 2…sitioning Chair Medline Industries Inc One Medline Place JL 60060 5 10(k) No. K001937 Dental Tilting Ramp TRICO Metal Products Wyandotte Rd,… | 2000 |
| * | — | Dental Tilting Ramp Named without a submission number | |
| * | — | Rehabilitation Hospital Philadelphia Named without a submission number |
What descends from it? (1)
1 later device cites it directly; ranked here by how many devices descend from each in turn.
| Number | Device | Decided | Descendants |
|---|---|---|---|
| K101723 | Compact Wheelchair Platform | 2010 | 0 |
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- The line of descent spans 20 years and passes through 4 companies; a new generation was cleared every 1.5 years on median.
- None of the 5 ancestors has a recall.
- Of its descendants, K101723 (Design Specific Fletcher, 2010) has gone furthest, with 0 descendants of its own.
- 1 other device also cites its predicate K071793.
How does its category compare?
All INO devicesINO Chair, Positioning, Electric: FDA decisions, review times, recalls and adverse event reports over 20 years. 2009, this device’s year, is highlighted.
FDA decisions per year · INO
1in 2014
2026 to Oct 25, outlined.
Median 510(k) review, days · INO
126in 2009
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · INO
1in 2022
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · INO
29in 2025
MAUDE reports naming product code INO, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 2 | — | 0 | 1 |
| 2008 | 2 | — | 0 | 5 |
| 2009 | 4 | 126 | 0 | 6 |
| 2010 | 1 | — | 0 | 7 |
| 2011 | 1 | — | 0 | 20 |
| 2012 | 0 | — | 0 | 15 |
| 2013 | 1 | — | 0 | 24 |
| 2014 | 1 | — | 0 | 16 |
| 2015 | 0 | — | 0 | 23 |
| 2016 | 0 | — | 0 | 35 |
| 2017 | 0 | — | 0 | 38 |
| 2018 | 0 | — | 0 | 38 |
| 2019 | 0 | — | 0 | 37 |
| 2020 | 0 | — | 0 | 41 |
| 2021 | 0 | — | 0 | 49 |
| 2022 | 0 | — | 1 | 29 |
| 2023 | 0 | — | 0 | 29 |
| 2024 | 0 | — | 0 | 20 |
| 2025 | 0 | — | 0 | 29 |
| 2026 | 0 | — | 0 | — |
What is it indicated for?
Patients in wheelchairs present problems to clinicians who need to treat them and the patients themselves can be seriously disadvantaged by their situation. This is particularly true of dental treatment. To be treated the dentist would need to bend around the patient in the wheelchair, that cusses back pain and sometimes injury. An alternate approach is to transfer the patient to a conventional chair by slings and hoists or other approaches, all of which…
Read the full statement (139 words)
Patients in wheelchairs present problems to clinicians who need to treat them and the patients themselves can be seriously disadvantaged by their situation. This is particularly true of dental treatment. To be treated the dentist would need to bend around the patient in the wheelchair, that cusses back pain and sometimes injury. An alternate approach is to transfer the patient to a conventional chair by slings and hoists or other approaches, all of which hold significant health and safety risks.
The wheelchair platform offers a safe environment for both clinician and patient. The wheelchair is moved onto the platform up against a back wall support and the wheelchair and patient are then supported by a backrest and a head support. The platform is reclined, and possibly raised and lowered, to present the patient in the best position for treatment.
Indications for use as stated in the FDA summary.
https://510kreport.com/device/K073565 · printed Nov 6, 2026
Cite this page
510(k) Report. “K073565: Standard Wheelchair Platform.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K073565
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026