510(k) Report

510(k) · Cleared

Cleared

Sensititre 18 - 24 Hour Susceptibility Plate

K073653510(k) TraditionalCleared Mar 20, 200885-day reviewClass II21 CFR 866.1640

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Trek Diagnostic Systems, Inc. · JWY Manual Antimicrobial Susceptibility Test Systems

Cleared on Mar 20, 2008 after an 85-day review. FDA’s file for it is a 510(k) statement, which names no predicate. 1 later device descends from it.

Decided
Mar 20, 2008
Review
85 days
Class
Class II
Product code
JWY
Recalls
None
Predicates
0

1 later device descends from it, 1 citing it directly.

Descendants, by year cleared 2008: 1 descendant cleared20052010201520202025
  1. This deviceK073653 Sensititre 18 - 24 Hour Susceptibility PlateTrek Diagnostic Systems, Inc. · 2008
  2. Descendant · cites it directly · 0 of its ownK082538 BD Phoenix Automated Microbiology System-Phoenix Inducible Macrolide…Becton, Dickinson & CO · 2008 · Recalled

Most influential descendants

Showing 1 of 1 · See all
  • K082538BD Phoenix Automated Microbiology System-Phoenix Inducible Macrolide Resistance TestBecton, Dickinson & CO · 2008 · cites it directly0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
0 (this device)K073653Sensititre 18 - 24 Hour Susceptibility PlateTrek Diagnostic Systems, Inc.2008—
+1K082538BD Phoenix Automated Microbiology System-Phoenix Inducible Macrolide…Becton, Dickinson & CO20081

Descendants by year cleared

Year clearedDevicesWith a Class I recall
200810
FIG. 1 — Lineage of K073653, 2008–2008Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA 510(k) statement (indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in JWY? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new JWY device

  1. #1 K260447 ETEST Gepotidacin (GEP) (0.016-256 µg/mL)score 12.7 · 6 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against?

FDA’s file for it is a 510(k) statement, which names no predicate.

What descends from it? (1)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K082538BD Phoenix Automated Microbiology System-Phoenix Inducible Macrolide Resistance TestBecton, Dickinson & CO20080

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • Of its descendants, K082538 (Becton, Dickinson & CO, 2008) has gone furthest, with 0 descendants of its own.

How does its category compare?

All JWY devices

JWY Manual Antimicrobial Susceptibility Test Systems: FDA decisions, review times, recalls and adverse event reports over 20 years. 2008, this device’s year, is highlighted.

FDA decisions per year · JWY

14in 2025

2008: 62009: 22010: 42011: 42012: 12014: 62015: 92016: 42017: 142018: 122019: 182020: 52021: 52023: 72024: 62025: 142026 (partial year): 2
2007high 18 (2019) · low 0 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · JWY

106in 2025

2008: 85 days median2010: 73 days median2011: 125 days median2014: 106 days median2015: 90 days median2016: 88 days median2017: 61 days median2018: 51 days median2019: 60 days median2020: 66 days median2021: 266 days median2023: 85 days median2024: 90 days median2025: 106 days median
2007high 266 (2021) · low 51 (2018)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · JWY

31in 2022

2008: 12011: 32014: 52015: 6, 4 Class I2017: 22022: 31, 9 Class I
2007high 31 (2022) · low 0 (2007)2026

Class I (13 since 2007) Class II/III not classified

Adverse event reports per year · JWY

1in 2024

2008: 12009: 12014: 42015: 112016: 202017: 92018: 132019: 102020: 202021: 412022: 112023: 92024: 1
2007high 41 (2021) · low 0 (2007)2025

MAUDE reports naming product code JWY, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—00
200868511
20092—01
201047300
2011412530
20121—00
20130—00
2014610654
20159906 (4)11
2016488020
2017146129
20181251013
20191860010
2020566020
20215266041
20220—31 (9)11
202378509
202469001
20251410600
20262—0—

What is it indicated for?

The Sensititre 18 - 24 hour MIC or Breakpoint Susceptibility System is an in vitro diagnostic product for clinical susceptibility testing of gram positive and gram negative organisms. This 510(k) is for the addition of: "Dtest" The Dtest for Broth Microdilution Test is for Staphylococcus spp. resistant to (MIC's > 8ug/ml) erythromycin and susceptible or intermediate (MIC's < 2ug/ml) to clindamycin. With these isolates a Dtest 1 (4/0.5 ug/ml) or 2 (8/1.5…

Read the full statement (114 words)

The Sensititre 18 - 24 hour MIC or Breakpoint Susceptibility System is an in vitro diagnostic product for clinical susceptibility testing of gram positive and gram negative organisms.

This 510(k) is for the addition of: "Dtest"

The Dtest for Broth Microdilution Test is for Staphylococcus spp. resistant to (MIC's > 8ug/ml) erythromycin and susceptible or intermediate (MIC's < 2ug/ml) to clindamycin. With these isolates a Dtest 1 (4/0.5 ug/ml) or 2 (8/1.5 ug/ml) or both 1 and 2 are positive (growth) the test should be reported as inducible clindamycin resistance. If with these isolates there is no growth in both Dtest 1 and 2 the isolates should be reported as negative for inducible resistance.

Indications for use as stated in the FDA 510(k) statement.

Cite this page

510(k) Report. “K073653: Sensititre 18 - 24 Hour Susceptibility Plate.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K073653

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026