Advanced Surgical Concepts · GCJ Laparoscope, General & Plastic Surgery

Cleared on Jan 29, 2008 as substantially equivalent to K073170 (Advanced Surgical Concepts, 2007) and 4 other predicates after a 29-day review. Its family tree reaches back 3 generations to 2001. 13 later devices descend from it.

Decided
Jan 29, 2008
Review
29 days
Class
Class II
Product code
GCJ
Recalls
None
Predicates
5

Its longest line of descent runs back 3 generations to K010007 (2001). 6 ancestors in all. 13 later devices descend from it, 5 citing it directly.

Other ancestors, by year clearedDescendants, by year cleared 2003: 1 other ancestor2001: 1 other ancestor2006: 1 other ancestor2015: 1 descendant cleared2024: 1 descendant cleared2009: 1 descendant cleared2010: 3 descendants cleared2011: 2 descendants cleared2016: 1 descendant cleared2022: 1 descendant cleared2012: 3 descendants clearedK010007 · Adapt Laparoscopic Port & Adapt Reducer Cap · Taut, Inc. · 2001 · recalledK070158 · R-Port Laparoscopic Access Device · Advanced Surgical Concepts · 2007K073170 · R-Port II Laparoscopic Access Device · Advanced Surgical Concepts · 2007200020052010201520202025
Other ancestors, by generationDescendants, by generation 1 generation back: 2 other ancestors2 generations back: 1 other ancestor 1 generation forward: 5 descendants2 generations forward: 5 descendants3 generations forward: 3 descendants K073170 · R-Port II Laparoscopic Access Device · Advanced Surgical Concepts · 2007K070158 · R-Port Laparoscopic Access Device · Advanced Surgical Concepts · 2007K010007 · Adapt Laparoscopic Port & Adapt Reducer Cap · Taut, Inc. · 2001 · recalled0
  1. Root · 3 generations backK010007 Adapt Laparoscopic Port & Adapt Reducer CapTaut, Inc. · 2001 · Recalled
  2. 2 generations backK070158 R-Port Laparoscopic Access DeviceAdvanced Surgical Concepts · 2007
  3. 1 generation backK073170 R-Port II Laparoscopic Access DeviceAdvanced Surgical Concepts · 2007
  4. This deviceK073719 Asc Triport Laparoscopic Access DeviceAdvanced Surgical Concepts · 2008
  5. Descendant · cites it directly · 5 of its ownK100045 OCTODalim Surgnet Corporation · 2010
  6. Descendant · 2 generations on · 4 of its ownK112196 OctotmportDalim Surgnet Corporation · 2011
  7. Descendant · cites it directly · 4 of its ownK101794 Asc Triport Laparoscopic Access Device Model TPRT-02-01 (WA58000T)…Advanced Surgical Concepts · 2010
  8. Descendant · cites it directly · 3 of its ownK141715 Glove PortNelis · 2015
  9. Descendant · 2 generations on · 3 of its ownK110004 Asc Triport+ Laparoscopic Access DeviceAdvanced Surgical Concepts · 2011

Showing 5 of 13 descendants. See all descendants

Descendants cleared per year

2009: 12010: 32011: 22012: 32015: 12016: 12022: 12024: 1
2009high 3 (2010) · low 0 (2013)2026

Most influential descendants

Showing 5 of 13 · See all
  • K100045OCTODalim Surgnet Corporation · 2010 · cites it directly5descendants
  • K112196OctotmportDalim Surgnet Corporation · 2011 · 2 generations on4descendants
  • K101794Asc Triport Laparoscopic Access Device Model TPRT-02-01 (WA58000T), Asc Quadport…Advanced Surgical Concepts · 2010 · cites it directly4descendants
  • K141715Glove PortNelis · 2015 · cites it directly3descendants
  • K110004Asc Triport+ Laparoscopic Access DeviceAdvanced Surgical Concepts · 2011 · 2 generations on3descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−3K010007Adapt Laparoscopic Port & Adapt Reducer CapTaut, Inc.20013
−2K070158R-Port Laparoscopic Access DeviceAdvanced Surgical Concepts2007—
−1K073170R-Port II Laparoscopic Access DeviceAdvanced Surgical Concepts2007—
0 (this device)K073719Asc Triport Laparoscopic Access DeviceAdvanced Surgical Concepts2008—
+1K100045OCTODalim Surgnet Corporation2010—
+2K112196OctotmportDalim Surgnet Corporation2011—
+1K101794Asc Triport Laparoscopic Access Device Model TPRT-02-01 (WA58000T), Asc…Advanced Surgical Concepts2010—
+1K141715Glove PortNelis2015—
+2K110004Asc Triport+ Laparoscopic Access DeviceAdvanced Surgical Concepts2011—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
200110
200310
200610

Descendants by year cleared

Year clearedDevicesWith a Class I recall
200910
201030
201120
201230
201510
201610
202210
202410
FIG. 1 — Lineage of K073719, 2001–2024Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in GCJ? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new GCJ device

  1. #1 K214046 780 nm 1688 4K Camera System, 780 nm L11 LED…score 21.4 · 21 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (5)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K073170R-Port II Laparoscopic Access Device
Summary page 1
…Accessory Classification Name: Endoscopic Accessory and Surgical Retractor 3. PREDICATE DEVICES * R-Port II Laparoscopic Access Device subject of K073170 * R-Port Laparoscopic Access Device subject of K070158 * Taut Inc. ADAPt Laparoscopic Port and Accessory subject of…
Advanced Surgical Concepts2007—
*K070158R-Port Laparoscopic Access Device
Summary page 1
…ry and Surgical Retractor 3. PREDICATE DEVICES * R-Port II Laparoscopic Access Device subject of K073170 * R-Port Laparoscopic Access Device subject of K070158 * Taut Inc. ADAPt Laparoscopic Port and Accessory subject of KO10007 • Ethicon Endopath III Trocar System subject o…
Advanced Surgical Concepts2007—
*K010007Adapt Laparoscopic Port & Adapt Reducer CapTaut, Inc.20013
*K032676Endopath Bladeless Trocar, Endopath Blunt Tip Trocar, Endopath Dilating Tip Trocar
Summary page 1
…copic Access Device subject of K070158 * Taut Inc. ADAPt Laparoscopic Port and Accessory subject of KO10007 • Ethicon Endopath III Trocar System subject of K032676 • ASC Ecotract Device subject of K01071 I 4. DEVICE DESCRIPTION The ASC TriPort Laparoscopic Access Device is a l…
Ethicon Endo-Surgery, Inc.20036
*K010711Ecotract Adjustable Wound Protector/RetractorAdvanced Surgical Concepts (Asc)2001—

Also cleared against K073170: 2 other devices →

What descends from it? (13)

See all 13

5 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K100045OCTODalim Surgnet Corporation20105
K101794Asc Triport Laparoscopic Access Device Model TPRT-02-01 (WA58000T), Asc Quadport…Advanced Surgical Concepts20104
K141715Glove PortNelis20153
K090677Innoport Laparoscopic Access DeviceInnovia, LLC20091
K233263Disposable TrocarsHangzhou Kangji Medical Instrument Co., Ltd.20240

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 7 years and passes through 2 companies; a new generation was cleared every 3 months on median.
  • 2 of the 6 ancestors have a recall of any class.
  • Of its descendants, K100045 (Dalim Surgnet Corporation, 2010) has gone furthest, with 5 descendants of its own.
  • 2 other devices also cite its predicate K073170.

How does its category compare?

All GCJ devices

GCJ Laparoscope, General & Plastic Surgery: FDA decisions, review times, recalls and adverse event reports over 20 years. 2008, this device’s year, is highlighted.

FDA decisions per year · GCJ

21in 2025

2007: 182008: 192009: 212010: 242011: 152012: 172013: 152014: 192015: 262016: 272017: 202018: 212019: 152020: 282021: 182022: 202023: 312024: 292025: 212026 (partial year): 26
2007high 31 (2023) · low 15 (2011)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · GCJ

108in 2025

2007: 42 days median2008: 73 days median2009: 85 days median2010: 122 days median2011: 113 days median2012: 88 days median2013: 93 days median2014: 90 days median2015: 76 days median2016: 99 days median2017: 77 days median2018: 88 days median2019: 60 days median2020: 61 days median2021: 116 days median2022: 103 days median2023: 109 days median2024: 90 days median2025: 108 days median2026 (partial year): 122 days median
2007high 122 (2010) · low 42 (2007)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · GCJ

5in 2025

2007: 122008: 162009: 62010: 302011: 92012: 12013: 7, 1 Class I2014: 22016: 52017: 12018: 12022: 12023: 12025: 52026 (partial year): 1
2007high 30 (2010) · low 0 (2015)2026

Class I (1 since 2007) Class II/III not classified

Adverse event reports per year · GCJ

5,860in 2025

2007: 1,6392008: 1,3192009: 1,9952010: 2,6572011: 2,1332012: 1,5262013: 1,5652014: 1,7142015: 1,7102016: 2,0802017: 3,4682018: 2,5622019: 2,5782020: 2,6182021: 3,4312022: 3,9452023: 6,0022024: 6,0472025: 5,860
2007high 6,047 (2024) · low 1,319 (2008)2025

MAUDE reports naming product code GCJ, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20071842121,639
20081973161,319
2009218561,995
201024122302,657
20111511392,133
2012178811,526
201315937 (1)1,565
2014199021,714
2015267601,710
2016279952,080
2017207713,468
2018218812,562
2019156002,578
2020286102,618
20211811603,431
20222010313,945
20233110916,002
2024299006,047
20252110855,860
2026261221—

What is it indicated for?

The ASC TriPort Laparoscopic Access Device is intended for use as a multiple instrument and/or camera port during minimally invasive abdominal laparoscopic surgery.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K073719: Asc Triport Laparoscopic Access Device.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K073719

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026