Ambulo 2400

K080274510(k) TraditionalCleared Apr 23, 200882-day reviewClass II21 CFR 870.1130

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Tiba Medical, Inc. · DXN System, Measurement, Blood-Pressure, Non-Invasive

Cleared on Apr 23, 2008 as substantially equivalent to K992808 (A&D Medical Div., 1999) after an 82-day review. Its family tree reaches back 1 generation to 1999. 5 later devices descend from it.

Decided
Apr 23, 2008
Review
82 days
Class
Class II
Product code
DXN
Recalls
None
Predicates
1

Its longest line of descent runs back 1 generation to K992808 (1999). 5 later devices descend from it, 1 citing it directly.

Descendants, by year cleared 2014: 1 descendant cleared2016: 1 descendant cleared2021: 1 descendant cleared2026: 2 descendants clearedK992808 · A&D Medical TM-2430 and TM-2431 Ambulatory Blood Pressure · A&D Medical Div. · 19991995200020052010201520202025
Descendants, by generation 1 generation forward: 1 descendant2 generations forward: 1 descendant3 generations forward: 2 descendants4 generations forward: 1 descendant K992808 · A&D Medical TM-2430 and TM-2431 Ambulatory Blood Pressure · A&D Medical Div. · 19990
  1. Root · 1 generation backK992808 A&D Medical TM-2430 and TM-2431 Ambulatory Blood PressureA&D Medical Div. · 1999
  2. This deviceK080274 Ambulo 2400Tiba Medical, Inc. · 2008
  3. Descendant · cites it directly · 4 of its ownK133989 Ambulo 2400 Ambulatory Blood Pressure Monitoring SystemMortara Instrument, Inc. · 2014
  4. Descendant · 2 generations on · 3 of its ownK151520 Oscar 2Suntech Medical, Inc. · 2016 · Recalled
  5. Descendant · 3 generations on · 1 of its ownK210139 Ambulatory Blood Pressure Monitor, Models: SA-10, SA-05, SA-06…Edan Instruments, Inc. · 2021
  6. Descendant · 3 generations on · 0 of its ownK251581 Wearable Ambulatory Blood Pressure Monitor (WBP-02A)Shenzhen Hingmed Medical Instrument Co., Ltd. · 2026
  7. Descendant · 4 generations on · 0 of its ownK251591 Holter ECG and ABP system (HolterABP)Edan Instruments, Inc. · 2026

Most influential descendants

Showing 5 of 5 · See all
  • K133989Ambulo 2400 Ambulatory Blood Pressure Monitoring SystemMortara Instrument, Inc. · 2014 · cites it directly4descendants
  • K151520Oscar 2Suntech Medical, Inc. · 2016 · 2 generations on3descendants
  • K210139Ambulatory Blood Pressure Monitor, Models: SA-10, SA-05, SA-06, SA-08 and SA-09Edan Instruments, Inc. · 2021 · 3 generations on1descendant
  • K251581Wearable Ambulatory Blood Pressure Monitor (WBP-02A)Shenzhen Hingmed Medical Instrument Co., Ltd. · 2026 · 3 generations on0descendants
  • K251591Holter ECG and ABP system (HolterABP)Edan Instruments, Inc. · 2026 · 4 generations on0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−1K992808A&D Medical TM-2430 and TM-2431 Ambulatory Blood PressureA&D Medical Div.1999—
0 (this device)K080274Ambulo 2400Tiba Medical, Inc.2008—
+1K133989Ambulo 2400 Ambulatory Blood Pressure Monitoring SystemMortara Instrument, Inc.2014—
+2K151520Oscar 2Suntech Medical, Inc.20162
+3K210139Ambulatory Blood Pressure Monitor, Models: SA-10, SA-05, SA-06, SA-08 and SA-09Edan Instruments, Inc.2021—
+3K251581Wearable Ambulatory Blood Pressure Monitor (WBP-02A)Shenzhen Hingmed Medical Instrument Co., Ltd.2026—
+4K251591Holter ECG and ABP system (HolterABP)Edan Instruments, Inc.2026—

Descendants by year cleared

Year clearedDevicesWith a Class I recall
201410
201610
202110
202620
FIG. 1 — Lineage of K080274, 1999–2026Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in DXN? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new DXN device

  1. #1 K222125 Arm Blood Pressure Monitor, models AOJ-30A…score 18.5 · 8 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K992808A&D Medical TM-2430 and TM-2431 Ambulatory Blood Pressure
Summary page 1
…The Arrbulo 2400 is substantially equivalent to the A&D Medical model TM-2430 Ambulatory Blood Pressure Monitoring system cleared for marker under K992808. Device Description: The Ambulo 2400 is a compact, lightweight, non-invasive ambulatory blood monitoring sys…
A&D Medical Div.1999—

Also cleared against K992808: 2 other devices →

What descends from it? (5)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K133989Ambulo 2400 Ambulatory Blood Pressure Monitoring SystemMortara Instrument, Inc.20144

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • Its one ancestor has no recall.
  • Of its descendants, K133989 (Mortara Instrument, Inc., 2014) has gone furthest, with 4 descendants of its own.
  • 2 other devices also cite its predicate K992808.

How does its category compare?

All DXN devices

DXN System, Measurement, Blood-Pressure, Non-Invasive: FDA decisions, review times, recalls and adverse event reports over 20 years. 2008, this device’s year, is highlighted.

FDA decisions per year · DXN

28in 2025

2007: 272008: 232009: 462010: 432011: 342012: 362013: 342014: 292015: 302016: 302017: 332018: 222019: 332020: 242021: 232022: 252023: 352024: 172025: 282026 (partial year): 29
2007high 46 (2009) · low 17 (2024)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · DXN

142in 2025

2007: 118 days median2008: 82 days median2009: 73 days median2010: 94 days median2011: 72 days median2012: 116 days median2013: 150 days median2014: 133 days median2015: 97 days median2016: 144 days median2017: 184 days median2018: 235 days median2019: 156 days median2020: 198 days median2021: 190 days median2022: 137 days median2023: 182 days median2024: 107 days median2025: 142 days median2026 (partial year): 147 days median
2007high 235 (2018) · low 72 (2011)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · DXN

3in 2024

2008: 12009: 32011: 12013: 12016: 12019: 12024: 3
2007high 3 (2009) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · DXN

239in 2025

2007: 212008: 82009: 172010: 142011: 102012: 192013: 722014: 472015: 622016: 542017: 902018: 6172019: 962020: 1302021: 1622022: 1552023: 1622024: 2702025: 239
2007high 617 (2018) · low 8 (2008)2025

MAUDE reports naming product code DXN, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
200727118021
2008238218
20094673317
20104394014
20113472110
201236116019
201334150172
201429133047
20153097062
201630144154
201733184090
2018222350617
201933156196
2020241980130
2021231900162
2022251370155
2023351820162
2024171073270
2025281420239
2026291470—

What is it indicated for?

The Ambulo 2400 Ambulatory Blood Pressure Monitor is designed to measure systolic and diastolic blood pressure and pulse rate of adults who are eighteen (18) years and older, using the oscillometric method on a cuffed arm.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K080274: Ambulo 2400.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 3, 2026. https://510kreport.com/device/K080274

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026