510(k) Report

510(k) · Cleared

Recalled · Class II · 2019

HLM Tubing Set with Bioline Coating

K080592510(k) SpecialCleared Sep 11, 2008192-day reviewClass II21 CFR 870.4390Recalls 221

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Maquet Cardiopulmonary, AG · DWE Tubing, Pump, Cardiopulmonary Bypass

Cleared on Sep 11, 2008 as substantially equivalent to K053025 (Maquet Cardiopulmonary, AG, 2005) and 1 other predicate after a 192-day review. Its family tree reaches back 5 generations to 1993. 3 of the 23 devices in its family, counting itself, have a Class I recall. 8 later devices descend from it. It has been recalled 221 times.

Decided
Sep 11, 2008
Review
192 days
Class
Class II
Product code
DWE
Recalls
221
Predicates
2

Its longest line of descent runs back 5 generations to K932252 (1993). 14 ancestors in all, the oldest K771692 (1977). 8 later devices descend from it, 4 citing it directly. 3 of the 23 devices in this family, counting this one, have a Class I recall.

Other ancestors, by year clearedDescendants, by year cleared 2005: 1 other ancestor2004: 1 other ancestor2002: 2 other ancestors1988: 1 other ancestor1983: 1 other ancestor1980: 1 other ancestor1977: 1 other ancestor1989: 1 other ancestor2009: 2 descendants cleared2020: 1 descendant cleared, 1 with a Class I recall12011: 1 descendant cleared, 1 with a Class I recall12013: 1 descendant cleared2014: 1 descendant cleared, 1 with a Class I recall12023: 1 descendant cleared2022: 1 descendant clearedK932252 · Affinity Hollow Fiber Oxygenator · Avecor Cardiovascular, Inc. · 1993K992559 · Hollow Fiber Membrane Oygenator Quadrox Hmo 1010 · Jostra Bentley · 1999K030264 · Quandrox Safeline Hollow Fiber Membrane Oxygenator, Model Hmo 2030 · Jostra AG · 2003K061628 · Jostra Quadrox D Safeline Diffusion Membrane Oxygenator, Model Hmod 2030 · Maquet Cardiopulmonary, AG · 2006K071774 · Jostra Quadrox D Diffusion Membrane Oxygenator with Bioline Coating, Model BE-Hmod 2000, Beq-Hmod 2030 · Maquet Cardiopulmonary, AG · 200819801990200020102020
  1. Root · 5 generations backK932252 Affinity Hollow Fiber OxygenatorAvecor Cardiovascular, Inc. · 1993
  2. 4 generations backK992559 Hollow Fiber Membrane Oygenator Quadrox Hmo 1010Jostra Bentley · 1999
  3. 3 generations backK030264 Quandrox Safeline Hollow Fiber Membrane Oxygenator, Model Hmo 2030Jostra AG · 2003
  4. 2 generations backK061628 Jostra Quadrox D Safeline Diffusion Membrane Oxygenator, Model Hmod…Maquet Cardiopulmonary, AG · 2006
  5. 1 generation backK071774 Jostra Quadrox D Diffusion Membrane Oxygenator with Bioline Coating…Maquet Cardiopulmonary, AG · 2008
  6. This deviceK080592 HLM Tubing Set with Bioline CoatingMaquet Cardiopulmonary, AG · 2008
  7. Descendant · cites it directly · 3 of its ownK090533 HLM Tubing Set with Softline CoatingMaquet Cardiopulmonary, AG · 2009
  8. Descendant · cites it directly · 2 of its ownK200109 OXY-1 SystemAbiomed, Inc. · 2020 · Recalled (Class I)
  9. Descendant · cites it directly · 2 of its ownK102726 Cardiohelp SystemMaquet Cardiopulmonary, AG · 2011 · Recalled (Class I)
  10. Descendant · 2 generations on · 0 of its ownK223161 OXY-1 SystemAbiomed, Inc. · 2023
  11. Descendant · 2 generations on · 0 of its ownK222297 CentriMag Pre-connected PackAbbott · 2022

Showing 5 of 8 descendants. See all descendants

Descendants cleared per year

2009: 22011: 12013: 12014: 12020: 12022: 12023: 1
2009high 2 (2009) · low 0 (2010)2026

Class I recalls in this family

Most influential descendants

Showing 5 of 8 · See all
  • K090533HLM Tubing Set with Softline CoatingMaquet Cardiopulmonary, AG · 2009 · cites it directly3descendants
  • K200109OXY-1 SystemAbiomed, Inc. · 2020 · cites it directly2descendants
  • K102726Cardiohelp SystemMaquet Cardiopulmonary, AG · 2011 · cites it directly2descendants
  • K223161OXY-1 SystemAbiomed, Inc. · 2023 · 2 generations on0descendants
  • K222297CentriMag Pre-connected PackAbbott · 2022 · 2 generations on0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−5K932252Affinity Hollow Fiber OxygenatorAvecor Cardiovascular, Inc.1993—
−4K992559Hollow Fiber Membrane Oygenator Quadrox Hmo 1010Jostra Bentley1999—
−3K030264Quandrox Safeline Hollow Fiber Membrane Oxygenator, Model Hmo 2030Jostra AG2003—
−2K061628Jostra Quadrox D Safeline Diffusion Membrane Oxygenator, Model Hmod 2030Maquet Cardiopulmonary, AG2006—
−1K071774Jostra Quadrox D Diffusion Membrane Oxygenator with Bioline Coating, Model…Maquet Cardiopulmonary, AG2008—
0 (this device)K080592HLM Tubing Set with Bioline CoatingMaquet Cardiopulmonary, AG2008—
+1K090533HLM Tubing Set with Softline CoatingMaquet Cardiopulmonary, AG2009—
+1K200109OXY-1 SystemAbiomed, Inc.2020Class I
+1K102726Cardiohelp SystemMaquet Cardiopulmonary, AG2011Class I
+2K223161OXY-1 SystemAbiomed, Inc.2023—
+2K222297CentriMag Pre-connected PackAbbott2022—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
197710
198010
198310
198810
198910
200220
200410
200510

Descendants by year cleared

Year clearedDevicesWith a Class I recall
200920
201111
201310
201411
202011
202210
202310
FIG. 1 — Lineage of K080592, 1993–2023Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

3 devices in this family have a Class I recall. A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new DWE device

  1. #1 K233702 SMARxT Tubing and Connectorsscore 7.8 · 1 generation · no Class I recall
Get a 510(k) Report

What was it cleared against? (2)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K053025Jostra HLM Tubing Set
Summary page 1
…k, Manifold, or Fitting; Cardiopulmonary Bypass Pump Tubing. PREDICATE DEVICES OR LEGALLY MARKETED DEVICES Jostra HLM Tubing Sets (K053025) Quadrox D Diffusion Membrane Oxygenator with Bioline Coating (K071774) DEVICE DESCRIPTION / INDICATONS FOR USE STATEMENT…
Maquet Cardiopulmonary, AG20052
*K071774Jostra Quadrox D Diffusion Membrane Oxygenator with Bioline Coating, Model BE-Hmod 2000…
Summary page 1
…ry Bypass Pump Tubing. PREDICATE DEVICES OR LEGALLY MARKETED DEVICES Jostra HLM Tubing Sets (K053025) Quadrox D Diffusion Membrane Oxygenator with Bioline Coating (K071774) DEVICE DESCRIPTION / INDICATONS FOR USE STATEMENT The HLM Tubing Sets with Bioline Coating are for single use only. They ma…
Maquet Cardiopulmonary, AG2008—

Also cleared against K053025: 2 other devices →

What descends from it? (8)

4 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K090533HLM Tubing Set with Softline CoatingMaquet Cardiopulmonary, AG20093
K200109OXY-1 System Class IAbiomed, Inc.20202
K102726Cardiohelp System Class IMaquet Cardiopulmonary, AG20112
K083794Mecc Set with Bioline CoatingMaquet Cardiopulmonary, AG20090

Has anything in its family been recalled? (3 Class I)

Recalls of this device

DateClassRecallRoot causeReason
Apr 18, 2019Class IIZ-1534-2019Device DesignCustom Tubing Sets for Extracorporeal Circulation (ECC)-During sterilization, the closed stopcock/non-vented cap configuration may prevent the flow of humidity/ethylene oxide gas into the fluid-path between the closed port and the…
Apr 18, 2019Class IIZ-1597-2019Device DesignCustom Tubing Sets for Extracorporeal Circulation (ECC)-During sterilization, the closed stopcock/non-vented cap configuration may prevent the flow of humidity/ethylene oxide gas into the fluid-path between the closed port and the…
Apr 18, 2019Class IIZ-1645-2019Device DesignCustom Tubing Sets for Extracorporeal Circulation (ECC)-During sterilization, the closed stopcock/non-vented cap configuration may prevent the flow of humidity/ethylene oxide gas into the fluid-path between the closed port and the…
Apr 18, 2019Class IIZ-1513-2019Device DesignCustom Tubing Sets for Extracorporeal Circulation (ECC)-During sterilization, the closed stopcock/non-vented cap configuration may prevent the flow of humidity/ethylene oxide gas into the fluid-path between the closed port and the…
Apr 18, 2019Class IIZ-1543-2019Device DesignCustom Tubing Sets for Extracorporeal Circulation (ECC)-During sterilization, the closed stopcock/non-vented cap configuration may prevent the flow of humidity/ethylene oxide gas into the fluid-path between the closed port and the…
Apr 18, 2019Class IIZ-1541-2019Device DesignCustom Tubing Sets for Extracorporeal Circulation (ECC)-During sterilization, the closed stopcock/non-vented cap configuration may prevent the flow of humidity/ethylene oxide gas into the fluid-path between the closed port and the…
Apr 18, 2019Class IIZ-1590-2019Device DesignCustom Tubing Sets for Extracorporeal Circulation (ECC)-During sterilization, the closed stopcock/non-vented cap configuration may prevent the flow of humidity/ethylene oxide gas into the fluid-path between the closed port and the…
Apr 18, 2019Class IIZ-1648-2019Device DesignCustom Tubing Sets for Extracorporeal Circulation (ECC)-During sterilization, the closed stopcock/non-vented cap configuration may prevent the flow of humidity/ethylene oxide gas into the fluid-path between the closed port and the…
Apr 18, 2019Class IIZ-1605-2019Device DesignCustom Tubing Sets for Extracorporeal Circulation (ECC)-During sterilization, the closed stopcock/non-vented cap configuration may prevent the flow of humidity/ethylene oxide gas into the fluid-path between the closed port and the…
Apr 18, 2019Class IIZ-1622-2019Device DesignCustom Tubing Sets for Extracorporeal Circulation (ECC)-During sterilization, the closed stopcock/non-vented cap configuration may prevent the flow of humidity/ethylene oxide gas into the fluid-path between the closed port and the…
Apr 18, 2019Class IIZ-1606-2019Device DesignCustom Tubing Sets for Extracorporeal Circulation (ECC)-During sterilization, the closed stopcock/non-vented cap configuration may prevent the flow of humidity/ethylene oxide gas into the fluid-path between the closed port and the…
Apr 18, 2019Class IIZ-1641-2019Device DesignCustom Tubing Sets for Extracorporeal Circulation (ECC)-During sterilization, the closed stopcock/non-vented cap configuration may prevent the flow of humidity/ethylene oxide gas into the fluid-path between the closed port and the…
Apr 18, 2019Class IIZ-1506-2019Device DesignCustom Tubing Sets for Extracorporeal Circulation (ECC)-During sterilization, the closed stopcock/non-vented cap configuration may prevent the flow of humidity/ethylene oxide gas into the fluid-path between the closed port and the…
Apr 18, 2019Class IIZ-1666-2019Device DesignCustom Tubing Sets for Extracorporeal Circulation (ECC)-During sterilization, the closed stopcock/non-vented cap configuration may prevent the flow of humidity/ethylene oxide gas into the fluid-path between the closed port and the…
Apr 18, 2019Class IIZ-1586-2019Device DesignCustom Tubing Sets for Extracorporeal Circulation (ECC)-During sterilization, the closed stopcock/non-vented cap configuration may prevent the flow of humidity/ethylene oxide gas into the fluid-path between the closed port and the…
Apr 18, 2019Class IIZ-1500-2019Device DesignCustom Tubing Sets for Extracorporeal Circulation (ECC)-During sterilization, the closed stopcock/non-vented cap configuration may prevent the flow of humidity/ethylene oxide gas into the fluid-path between the closed port and the…
Apr 18, 2019Class IIZ-1508-2019Device DesignCustom Tubing Sets for Extracorporeal Circulation (ECC)-During sterilization, the closed stopcock/non-vented cap configuration may prevent the flow of humidity/ethylene oxide gas into the fluid-path between the closed port and the…
Apr 18, 2019Class IIZ-1658-2019Device DesignCustom Tubing Sets for Extracorporeal Circulation (ECC)-During sterilization, the closed stopcock/non-vented cap configuration may prevent the flow of humidity/ethylene oxide gas into the fluid-path between the closed port and the…
Apr 18, 2019Class IIZ-1585-2019Device DesignCustom Tubing Sets for Extracorporeal Circulation (ECC)-During sterilization, the closed stopcock/non-vented cap configuration may prevent the flow of humidity/ethylene oxide gas into the fluid-path between the closed port and the…
Apr 18, 2019Class IIZ-1644-2019Device DesignCustom Tubing Sets for Extracorporeal Circulation (ECC)-During sterilization, the closed stopcock/non-vented cap configuration may prevent the flow of humidity/ethylene oxide gas into the fluid-path between the closed port and the…
Apr 18, 2019Class IIZ-1565-2019Device DesignCustom Tubing Sets for Extracorporeal Circulation (ECC)-During sterilization, the closed stopcock/non-vented cap configuration may prevent the flow of humidity/ethylene oxide gas into the fluid-path between the closed port and the…
Apr 18, 2019Class IIZ-1612-2019Device DesignCustom Tubing Sets for Extracorporeal Circulation (ECC)-During sterilization, the closed stopcock/non-vented cap configuration may prevent the flow of humidity/ethylene oxide gas into the fluid-path between the closed port and the…
Apr 18, 2019Class IIZ-1578-2019Device DesignCustom Tubing Sets for Extracorporeal Circulation (ECC)-During sterilization, the closed stopcock/non-vented cap configuration may prevent the flow of humidity/ethylene oxide gas into the fluid-path between the closed port and the…
Apr 18, 2019Class IIZ-1593-2019Device DesignCustom Tubing Sets for Extracorporeal Circulation (ECC)-During sterilization, the closed stopcock/non-vented cap configuration may prevent the flow of humidity/ethylene oxide gas into the fluid-path between the closed port and the…
Apr 18, 2019Class IIZ-1525-2019Device DesignCustom Tubing Sets for Extracorporeal Circulation (ECC)-During sterilization, the closed stopcock/non-vented cap configuration may prevent the flow of humidity/ethylene oxide gas into the fluid-path between the closed port and the…
Apr 18, 2019Class IIZ-1615-2019Device DesignCustom Tubing Sets for Extracorporeal Circulation (ECC)-During sterilization, the closed stopcock/non-vented cap configuration may prevent the flow of humidity/ethylene oxide gas into the fluid-path between the closed port and the…
Apr 18, 2019Class IIZ-1646-2019Device DesignCustom Tubing Sets for Extracorporeal Circulation (ECC)-During sterilization, the closed stopcock/non-vented cap configuration may prevent the flow of humidity/ethylene oxide gas into the fluid-path between the closed port and the…
Apr 18, 2019Class IIZ-1552-2019Device DesignCustom Tubing Sets for Extracorporeal Circulation (ECC)-During sterilization, the closed stopcock/non-vented cap configuration may prevent the flow of humidity/ethylene oxide gas into the fluid-path between the closed port and the…
Apr 18, 2019Class IIZ-1518-2019Device DesignCustom Tubing Sets for Extracorporeal Circulation (ECC)-During sterilization, the closed stopcock/non-vented cap configuration may prevent the flow of humidity/ethylene oxide gas into the fluid-path between the closed port and the…
Apr 18, 2019Class IIZ-1549-2019Device DesignCustom Tubing Sets for Extracorporeal Circulation (ECC)-During sterilization, the closed stopcock/non-vented cap configuration may prevent the flow of humidity/ethylene oxide gas into the fluid-path between the closed port and the…
Apr 18, 2019Class IIZ-1634-2019Device DesignCustom Tubing Sets for Extracorporeal Circulation (ECC)-During sterilization, the closed stopcock/non-vented cap configuration may prevent the flow of humidity/ethylene oxide gas into the fluid-path between the closed port and the…
Apr 18, 2019Class IIZ-1621-2019Device DesignCustom Tubing Sets for Extracorporeal Circulation (ECC)-During sterilization, the closed stopcock/non-vented cap configuration may prevent the flow of humidity/ethylene oxide gas into the fluid-path between the closed port and the…
Apr 18, 2019Class IIZ-1511-2019Device DesignCustom Tubing Sets for Extracorporeal Circulation (ECC)-During sterilization, the closed stopcock/non-vented cap configuration may prevent the flow of humidity/ethylene oxide gas into the fluid-path between the closed port and the…
Apr 18, 2019Class IIZ-1608-2019Device DesignCustom Tubing Sets for Extracorporeal Circulation (ECC)-During sterilization, the closed stopcock/non-vented cap configuration may prevent the flow of humidity/ethylene oxide gas into the fluid-path between the closed port and the…
Apr 18, 2019Class IIZ-1635-2019Device DesignCustom Tubing Sets for Extracorporeal Circulation (ECC)-During sterilization, the closed stopcock/non-vented cap configuration may prevent the flow of humidity/ethylene oxide gas into the fluid-path between the closed port and the…
Apr 18, 2019Class IIZ-1509-2019Device DesignCustom Tubing Sets for Extracorporeal Circulation (ECC)-During sterilization, the closed stopcock/non-vented cap configuration may prevent the flow of humidity/ethylene oxide gas into the fluid-path between the closed port and the…
Apr 18, 2019Class IIZ-1503-2019Device DesignCustom Tubing Sets for Extracorporeal Circulation (ECC)-During sterilization, the closed stopcock/non-vented cap configuration may prevent the flow of humidity/ethylene oxide gas into the fluid-path between the closed port and the…
Apr 18, 2019Class IIZ-1656-2019Device DesignCustom Tubing Sets for Extracorporeal Circulation (ECC)-During sterilization, the closed stopcock/non-vented cap configuration may prevent the flow of humidity/ethylene oxide gas into the fluid-path between the closed port and the…
Apr 18, 2019Class IIZ-1620-2019Device DesignCustom Tubing Sets for Extracorporeal Circulation (ECC)-During sterilization, the closed stopcock/non-vented cap configuration may prevent the flow of humidity/ethylene oxide gas into the fluid-path between the closed port and the…
Apr 18, 2019Class IIZ-1517-2019Device DesignCustom Tubing Sets for Extracorporeal Circulation (ECC)-During sterilization, the closed stopcock/non-vented cap configuration may prevent the flow of humidity/ethylene oxide gas into the fluid-path between the closed port and the…
Apr 18, 2019Class IIZ-1671-2019Device DesignCustom Tubing Sets for Extracorporeal Circulation (ECC)-During sterilization, the closed stopcock/non-vented cap configuration may prevent the flow of humidity/ethylene oxide gas into the fluid-path between the closed port and the…
Apr 18, 2019Class IIZ-1529-2019Device DesignCustom Tubing Sets for Extracorporeal Circulation (ECC)-During sterilization, the closed stopcock/non-vented cap configuration may prevent the flow of humidity/ethylene oxide gas into the fluid-path between the closed port and the…
Apr 18, 2019Class IIZ-1663-2019Device DesignCustom Tubing Sets for Extracorporeal Circulation (ECC)-During sterilization, the closed stopcock/non-vented cap configuration may prevent the flow of humidity/ethylene oxide gas into the fluid-path between the closed port and the…
Apr 18, 2019Class IIZ-1662-2019Device DesignCustom Tubing Sets for Extracorporeal Circulation (ECC)-During sterilization, the closed stopcock/non-vented cap configuration may prevent the flow of humidity/ethylene oxide gas into the fluid-path between the closed port and the…
Apr 18, 2019Class IIZ-1618-2019Device DesignCustom Tubing Sets for Extracorporeal Circulation (ECC)-During sterilization, the closed stopcock/non-vented cap configuration may prevent the flow of humidity/ethylene oxide gas into the fluid-path between the closed port and the…
Apr 18, 2019Class IIZ-1537-2019Device DesignCustom Tubing Sets for Extracorporeal Circulation (ECC)-During sterilization, the closed stopcock/non-vented cap configuration may prevent the flow of humidity/ethylene oxide gas into the fluid-path between the closed port and the…
Apr 18, 2019Class IIZ-1676-2019Device DesignCustom Tubing Sets for Extracorporeal Circulation (ECC)-During sterilization, the closed stopcock/non-vented cap configuration may prevent the flow of humidity/ethylene oxide gas into the fluid-path between the closed port and the…
Apr 18, 2019Class IIZ-1594-2019Device DesignCustom Tubing Sets for Extracorporeal Circulation (ECC)-During sterilization, the closed stopcock/non-vented cap configuration may prevent the flow of humidity/ethylene oxide gas into the fluid-path between the closed port and the…
Apr 18, 2019Class IIZ-1561-2019Device DesignCustom Tubing Sets for Extracorporeal Circulation (ECC)-During sterilization, the closed stopcock/non-vented cap configuration may prevent the flow of humidity/ethylene oxide gas into the fluid-path between the closed port and the…
Apr 18, 2019Class IIZ-1661-2019Device DesignCustom Tubing Sets for Extracorporeal Circulation (ECC)-During sterilization, the closed stopcock/non-vented cap configuration may prevent the flow of humidity/ethylene oxide gas into the fluid-path between the closed port and the…

Relatives with a Class I recall

Class I is FDA’s most serious recall class. A recall in the family tree is context for this device, not evidence about it.

  • K200109OXY-1 SystemAbiomed, Inc. · 2020 · Cites it directly · ◆ in the 2020 descendants bar of FIG. 11 Class I recall
  • K102726Cardiohelp SystemMaquet Cardiopulmonary, AG · 2011 · Cites it directly · ◆ in the 2011 descendants bar of FIG. 11 Class I recall
  • K133598Cardiohelp SystemMaquet Cardiopulmonary, AG · 2014 · 2 generations on · ◆ in the 2014 descendants bar of FIG. 11 Class I recall

What does this lineage say?

  • The line of descent spans 15 years and passes through 4 companies; a new generation was cleared every 3.4 years on median.
  • 4 of the 14 ancestors have a recall of any class.
  • Of its descendants, K090533 (Maquet Cardiopulmonary, AG, 2009) has gone furthest, with 3 descendants of its own.
  • 2 other devices also cite its predicate K053025.

How does its category compare?

All DWE devices

DWE Tubing, Pump, Cardiopulmonary Bypass: FDA decisions, review times, recalls and adverse event reports over 20 years. 2008, this device’s year, is highlighted.

FDA decisions per year · DWE

1in 2024

2008: 12009: 12014: 12015: 12024: 1
2007high 1 (2008) · low 0 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · DWE

Too few DWE 510(k)s in any year since 2007 to give a median.

Recalls per year · DWE

2in 2017

2007: 22009: 12010: 22011: 22014: 12017: 2
2007high 2 (2007) · low 0 (2008)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · DWE

80in 2025

2007: 102008: 122009: 172010: 202011: 92012: 72013: 212014: 1292015: 1332016: 1512017: 1312018: 1342019: 822020: 452021: 412022: 1232023: 2862024: 2212025: 80
2007high 286 (2023) · low 7 (2012)2025

MAUDE reports naming product code DWE, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—210
20081—012
20091—117
20100—220
20110—29
20120—07
20130—021
20141—1129
20151—0133
20160—0151
20170—2131
20180—0134
20190—082
20200—045
20210—041
20220—0123
20230—0286
20241—0221
20250—080
20260—0—

What is it indicated for?

The HLM Tubing Sets with Bioline Coating are designed to be used in extracorporeal circulation during cardiopulmonary bypass procedures lasting six hours or less.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K080592: HLM Tubing Set with Bioline Coating.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K080592

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history