Duo-Max Blood Pressure & Glucose Monitor HMF-100

K080636510(k) TraditionalCleared Feb 13, 2009344-day reviewClass II21 CFR 862.1345

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Hubdic Co., Ltd. · CGA Glucose Oxidase, Glucose

Cleared on Feb 13, 2009 as substantially equivalent to K052108 (Sein Electronics Co., Ltd., 2005) and 1 other predicate after a 344-day review. Its family tree reaches back 4 generations to 2002.

Decided
Feb 13, 2009
Review
344 days
Class
Class II
Product code
CGA
Recalls
None
Predicates
2

Its longest line of descent runs back 4 generations to K021239 (2002). 14 ancestors in all, the oldest K942455 (1995). No later device cites it as a predicate yet.

Other ancestors, by year cleared 2005: 1 other ancestor2004: 1 other ancestor2003: 1 other ancestor2002: 2 other ancestors2000: 1 other ancestor1999: 1 other ancestor2001: 1 other ancestor1997: 1 other ancestor1995: 1 other ancestorK021239 · Eikon Automatic Digital Blood Pressure Monitor, Model HD-400M · Eikon Healthcare Device Corp. · 2002K040159 · Apm Blood Pressure Monitor, Model BP108A · Asia Pacific Microsystems, Inc. · 2004K042795 · Clever Chek TD-3213 · Taidoc Technology Corporation · 2005K052108 · Sein Blood Glucose and Blood Pressure Monitor System, Model BGP-100 · Sein Electronics Co., Ltd. · 20051995200020052010
  1. Root · 4 generations backK021239 Eikon Automatic Digital Blood Pressure Monitor, Model HD-400MEikon Healthcare Device Corp. · 2002
  2. 3 generations backK040159 Apm Blood Pressure Monitor, Model BP108AAsia Pacific Microsystems, Inc. · 2004
  3. 2 generations backK042795 Clever Chek TD-3213Taidoc Technology Corporation · 2005
  4. 1 generation backK052108 Sein Blood Glucose and Blood Pressure Monitor System, Model BGP-100Sein Electronics Co., Ltd. · 2005
  5. This deviceK080636 Duo-Max Blood Pressure & Glucose Monitor HMF-100Hubdic Co., Ltd. · 2009
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−4K021239Eikon Automatic Digital Blood Pressure Monitor, Model HD-400MEikon Healthcare Device Corp.2002—
−3K040159Apm Blood Pressure Monitor, Model BP108AAsia Pacific Microsystems, Inc.2004—
−2K042795Clever Chek TD-3213Taidoc Technology Corporation2005—
−1K052108Sein Blood Glucose and Blood Pressure Monitor System, Model BGP-100Sein Electronics Co., Ltd.2005—
0 (this device)K080636Duo-Max Blood Pressure & Glucose Monitor HMF-100Hubdic Co., Ltd.2009—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199510
199710
199910
200010
200110
200220
200310
200410
200510
FIG. 1 — Lineage of K080636, 2002–2009Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in CGA? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new CGA device

  1. #1 K252488 ABL90 FLEX PLUS Systemscore 12.8 · 6 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (2)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K052108Sein Blood Glucose and Blood Pressure Monitor System, Model BGP-100
Summary page 1
…NBW, CGA, JJX, DXN 3. Predicate Device: Blood Glucose and Blood Pressure Monitor System, Model BGP-100 Sein Electronics Co., Ltd K052108 Infopia GlucolabTM Blood Glucose Monitoring System K051285 4. Description: HuBDIC's Duo- Max Blood Pres…
Sein Electronics Co., Ltd.2005—
*K051285Glucolab Blood Glucose Monitoring System
Summary page 1
…Blood Glucose and Blood Pressure Monitor System, Model BGP-100 Sein Electronics Co., Ltd K052108 Infopia GlucolabTM Blood Glucose Monitoring System K051285 4. Description: HuBDIC's Duo- Max Blood Pressure and Glucose Monitor System, Model HMF-100 combines the…
Infopia Co, Ltd.2005—

Also cleared against K052108: 1 other device →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 7 years and passes through 5 companies; a new generation was cleared every 1.4 years on median.
  • 2 of the 14 ancestors have a recall of any class.
  • 1 other device also cites its predicate K052108.

How does its category compare?

All CGA devices

CGA Glucose Oxidase, Glucose: FDA decisions, review times, recalls and adverse event reports over 20 years. 2009, this device’s year, is highlighted.

FDA decisions per year · CGA

2in 2024

2007: 72008: 62009: 102010: 82011: 92012: 102013: 32014: 52015: 42016: 42017: 22018: 22019: 22020: 22021: 12022: 12023: 42024: 22026 (partial year): 1
2007high 10 (2009) · low 0 (2025)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · CGA

249in 2023

2007: 122 days median2008: 56 days median2009: 155 days median2010: 122 days median2011: 217 days median2012: 123 days median2013: 441 days median2014: 265 days median2015: 150 days median2016: 157 days median2023: 249 days median
2007high 441 (2013) · low 56 (2008)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · CGA

3in 2023

2007: 22008: 22009: 42010: 62011: 32013: 32014: 22015: 6, 2 Class I2016: 22019: 12023: 3
2007high 6 (2010) · low 0 (2012)2026

Class I (2 since 2007) Class II/III not classified

Adverse event reports per year · CGA

59in 2025

2007: 292008: 372009: 752010: 1722011: 4232012: 2332013: 1722014: 1222015: 1552016: 362017: 922018: 692019: 1162020: 682021: 482022: 2722023: 1,1412024: 2662025: 59
2007high 1,141 (2023) · low 29 (2007)2025

MAUDE reports naming product code CGA, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20077122229
2008656237
200910155475
201081226172
201192173423
2012101230233
201334413172
201452652122
201541506 (2)155
20164157236
20172—092
20182—069
20192—1116
20202—068
20211—048
20221—0272
2023424931,141
20242—0266
20250—059
20261—0—

What is it indicated for?

The Blood pressure and glucose monitor, Duo-MaxTM consists'of a meter with wrist cuff and glucose test strips. The glucose test system is intended for use in the quantitative measurement of glucose in capillary whobl blood taken from.the fingertip, dorsal hand, ventral palm, upper arm, forearn, calf and thigh. Glucose testing is- done outside the body (In Vitro diabetes mellitus, or in clinical settings by healthcare professionals. Glucose testing system…

Read the full statement (125 words)

The Blood pressure and glucose monitor, Duo-MaxTM consists'of a meter with wrist cuff and glucose test strips. The glucose test system is intended for use in the quantitative measurement of glucose in capillary whobl blood taken from.the fingertip, dorsal hand, ventral palm, upper arm, forearn, calf and thigh. Glucose testing is- done outside the body (In Vitro diabetes mellitus, or in clinical settings by healthcare professionals. Glucose testing system is not to be used for the diagnosis or screening of diabetes. It is not intended for use on neonates. Also the blood pressure test system measures systolic and diastolic blood pressure and pulse rate from adult's wrist in the home care environment. The device employs a wrist cuff and the oscillomentric metric method of measurement.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K080636: Duo-Max Blood Pressure & Glucose Monitor HMF-100.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 3, 2026. https://510kreport.com/device/K080636

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)