510(k) Report

510(k) · Cleared

Cleared

Ushifu Stepper

K080970510(k) TraditionalCleared Jun 11, 200868-day reviewClass II21 CFR 892.1570

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Ushifu Development Company, LLC · ITX Transducer, Ultrasonic, Diagnostic

Cleared on Jun 11, 2008 as substantially equivalent to K843573 (CIVCO Medical Instruments Co., Inc., 1984) after a 68-day review. Its family tree reaches back 1 generation to 1984.

Decided
Jun 11, 2008
Review
68 days
Class
Class II
Product code
ITX
Recalls
None
Predicates
1

Its longest line of descent runs back 1 generation to K843573 (1984). No later device cites it as a predicate yet.

K843573 · Civco-Super Scan/Biopsy Guide · CIVCO Medical Instruments Co., Inc. · 19841980198519901995200020052010
  1. Root · 1 generation backK843573 Civco-Super Scan/Biopsy GuideCIVCO Medical Instruments Co., Inc. · 1984
  2. This deviceK080970 Ushifu StepperUshifu Development Company, LLC · 2008
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−1K843573Civco-Super Scan/Biopsy GuideCIVCO Medical Instruments Co., Inc.1984—
0 (this device)K080970Ushifu StepperUshifu Development Company, LLC2008—
FIG. 1 — Lineage of K080970, 1984–2008Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in ITX? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new ITX device

  1. #1 K260114 Align® Cover and Pad Guidance Toolscore 13.6 · 6 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K843573Civco-Super Scan/Biopsy Guide
Summary page 1
…Stepper Classification Number: 21 CFR 892.1570 Classification Name: Transducer, Ultrasonic, Diagnostic Product Code: ITX Predicate Device: K843573, Super Scan/Biopsy Guide, CIVCO Statement of Intended The USHIFU Stepper is intended to provide support and Use.…
CIVCO Medical Instruments Co., Inc.1984—

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • Its one ancestor has no recall.

How does its category compare?

All ITX devices

ITX Transducer, Ultrasonic, Diagnostic: FDA decisions, review times, recalls and adverse event reports over 20 years. 2008, this device’s year, is highlighted.

FDA decisions per year · ITX

4in 2025

2007: 102008: 122009: 172010: 102011: 102012: 72013: 32014: 42015: 12016: 42017: 62018: 22019: 12020: 32021: 32022: 22023: 62024: 32025: 42026 (partial year): 6
2007high 17 (2009) · low 1 (2015)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · ITX

126in 2025

2007: 26 days median2008: 73 days median2009: 28 days median2010: 42 days median2011: 16 days median2012: 25 days median2013: 105 days median2014: 41 days median2016: 151 days median2017: 110 days median2020: 120 days median2021: 139 days median2023: 213 days median2024: 81 days median2025: 126 days median2026 (partial year): 158 days median
2007high 213 (2023) · low 16 (2011)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · ITX

2in 2025

2008: 42009: 42010: 42011: 12012: 12014: 12015: 52017: 12018: 152020: 32021: 10, 10 Class I2022: 62023: 12024: 12025: 2
2007high 15 (2018) · low 0 (2007)2026

Class I (10 since 2007) Class II/III not classified

Adverse event reports per year · ITX

571in 2025

2007: 162008: 392009: 232010: 302011: 342012: 292013: 382014: 432015: 1832016: 2692017: 4122018: 1302019: 1192020: 1162021: 1462022: 872023: 1382024: 9882025: 571
2007high 988 (2024) · low 16 (2007)2025

MAUDE reports naming product code ITX, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20071026016
20081273439
20091728423
20101042430
20111016134
2012725129
20133105038
2014441143
20151—5183
201641510269
201761101412
20182—15130
20191—0119
202031203116
2021313910 (10)146
20222—687
202362131138
20243811988
202541262571
202661580—

What is it indicated for?

The USHIFU Stepper is intended to provide support and stabilization for an ultrasonic probe during prostate imaging.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K080970: Ushifu Stepper.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 3, 2026. https://510kreport.com/device/K080970

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026