510(k) · Cleared
Recalled · 2009Provent Nasal Cannula
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Ventus Medical, Inc. · MNR Ventilatory Effort Recorder
Cleared on Aug 7, 2008 as substantially equivalent to K051313 (Salter Labs, 2005) and 3 other predicates after a 122-day review. Its family tree reaches back 3 generations to 1992. It has been recalled once.
- Decided
- Aug 7, 2008
- Review
- 122 days
- Class
- Class II
- Product code
- MNR
- Recalls
- 1
- Predicates
- 4
Its longest line of descent runs back 3 generations to K913396 (1992). 7 ancestors in all. No later device cites it as a predicate yet.
- Root · 3 generations backK913396 Cannula Style ThermocouplesPro-Tech, Inc. · 1992
- 2 generations backK982293 Pressure Transducer Airflow SensorPro-Tech Services, Inc. · 1998
- 1 generation backK051313 BI-Naps Nasal Airflow and Snore TransducerSalter Labs · 2005
- This deviceK080983 Provent Nasal CannulaVentus Medical, Inc. · 2008
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −3 | K913396 | Cannula Style Thermocouples | Pro-Tech, Inc. | 1992 | — |
| −2 | K982293 | Pressure Transducer Airflow Sensor | Pro-Tech Services, Inc. | 1998 | — |
| −1 | K051313 | BI-Naps Nasal Airflow and Snore Transducer | Salter Labs | 2005 | — |
| 0 (this device) | K080983 | Provent Nasal Cannula | Ventus Medical, Inc. | 2008 | — |
Other ancestors by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 1997 | 1 | 0 |
| 1998 | 2 | 0 |
| 2005 | 1 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in MNR? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new MNR device
- #1 K244027 Sansa Hsatscore 18.1 · 12 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (4)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K051313 | BI-Naps Nasal Airflow and Snore TransducerSummary page 1…Product Code MNR) Predicate Device: Predicate devices included in the 510(k) Notification are as follows: K,051313, Salter Labs Bi-NAPS Nasal Airflow and Snore Transducer K984431, B… | 2005 |
| * | K984431 | Ultima Airflow Pressure SensorSummary page 1…are as follows: K,051313, Salter Labs Bi-NAPS Nasal Airflow and Snore Transducer K984431, Braebon Medical Ultima Airflow Sensor K971501, Bio-logic Airflow Pressure Transducer… | 1998 |
| * | K971501 | Sleepscan Airflow Pressure TransducerSummary page 1…asal Airflow and Snore Transducer K984431, Braebon Medical Ultima Airflow Sensor K971501, Bio-logic Airflow Pressure Transducer K053063, Pro-Flow Multipurpose Cannula Device Description: The… | 1997 |
| * | K053063 | Pro-Flow Multipurpose CannulaSummary page 1…K984431, Braebon Medical Ultima Airflow Sensor K971501, Bio-logic Airflow Pressure Transducer K053063, Pro-Flow Multipurpose Cannula Device Description: The Provent Nasal Cannula was developed to transmit pressure signals from th… | 2005 |
What descends from it?
No later submission names this one as a predicate yet.
Has anything in its family been recalled? (0 Class I)
Recalls of this device
| Date | Class | Recall | Root cause | Reason |
|---|---|---|---|---|
| Dec 3, 2009 | Not classified | Z-2435-2010 | Labeling mix-ups | The catalog number printed on two Nasal Cannula Diagnostic Kits (MRS0231) was different that the catalog number printed on the bulk pack shipper box and the other Nasal Cannula Kits in the same shipper (MRS0208). No devices were used on… |
No ancestor or descendant has a Class I recall.
What does this lineage say?
- The line of descent spans 16 years and passes through 4 companies; a new generation was cleared every 6.1 years on median.
- None of the 7 ancestors has a recall.
- 2 other devices also cite its predicate K051313.
How does its category compare?
All MNR devicesMNR Ventilatory Effort Recorder: FDA decisions, review times, recalls and adverse event reports over 20 years. 2008, this device’s year, is highlighted.
FDA decisions per year · MNR
10in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · MNR
165in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · MNR
1in 2021
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · MNR
43in 2025
MAUDE reports naming product code MNR, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 6 | 124 | 2 | 1 |
| 2008 | 14 | 118 | 0 | 0 |
| 2009 | 8 | 89 | 1 | 0 |
| 2010 | 0 | — | 0 | 1 |
| 2011 | 9 | 90 | 1 | 1 |
| 2012 | 1 | — | 0 | 1 |
| 2013 | 4 | 161 | 0 | 0 |
| 2014 | 2 | — | 0 | 1 |
| 2015 | 4 | 229 | 0 | 4 |
| 2016 | 3 | 281 | 0 | 10 |
| 2017 | 4 | 275 | 0 | 4 |
| 2018 | 3 | 147 | 0 | 2 |
| 2019 | 8 | 383 | 0 | 3 |
| 2020 | 5 | 192 | 0 | 5 |
| 2021 | 3 | 137 | 1 | 5 |
| 2022 | 7 | 266 | 0 | 4 |
| 2023 | 6 | 183 | 0 | 13 |
| 2024 | 6 | 217 | 0 | 11 |
| 2025 | 10 | 165 | 0 | 43 |
| 2026 | 5 | 227 | 1 | — |
What is it indicated for?
The Provent Nasal Cannula is indicated for the transmission of respiratory airflow signals between the ProventTM Professional Sleep Apnea Therapy device and the pressure transducers used with physiologic recorders during sleep studies.
Indications for use as stated in the FDA summary.
https://510kreport.com/device/K080983 · printed Nov 6, 2026
Cite this page
510(k) Report. “K080983: Provent Nasal Cannula.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K080983
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026