# K081137: Intuitive Surgical DA Vinci SI Surgical System: Model IS3000

- Pathway: 510(k) (Traditional)
- Applicant: Intuitive Surgical, Inc.
- Decided: Feb 18, 2009 after 303 days
- Product code: NAY (System, Surgical, Computer Controlled Instrument)
- Device class: 2
- Regulation: 21 CFR 876.1500
- Recalls of this device: 25 (0 Class I)
- Data: FDA decisions to Oct 25, 2026; recalls to Oct 12, 2026

## Lineage
Longest line of descent: 10 generations back to K930667 (1994). 44 ancestors in all.
211 later devices descend from it; 29 cite it directly.
1 of 256 devices in its family (counting itself) has a Class I recall.

## Predicates on the family tree (from the FDA summary)
- K050369: Intuitive Surgical DA Vinci Surgical System, Model IS2000, Intuitive Surgical, Inc. (2005) Summary page 2.
- K063220: DA Vinci S Surgical System-V1.1, Model IS2000, Intuitive Surgical, Inc. (2006) Summary page 2.

## Most influential descendants
- K090993: Intuitive Surgical Endoscopic Instrument Control Systems, Models IS1200, IS2000 and IS3000 (2009), 153 descendants of its own
- K123463: Intuitive Surgical DA Vinci SI Surgical System Smartpedals (2012), 148 descendants of its own
- K131861: DA Vinci Surgical System, Endowrist Instruments and Accessories (2014), 124 descendants of its own
- K101077: DA Vinci Fluorescence Imaging Vision System, Model FF 100 (2011), 104 descendants of its own
- K124031: DA Vinci Fluorescence Imaging Vision System (2013), 103 descendants of its own

## Recalls of this device
- Jul 16, 2018 · Class II · Z-3254-2018: Certain Redundant Medical Grade Power Supply (RMGPS) units specific to Surgeon Console and Patient Side Carts were manufactured incorrectly and may fail prior or during use.
- Mar 16, 2016 · Class II · Z-1377-2016: Intuitive Surgical has found that the use of instruments other than the Cardiac Probe Grasper (e.g. Large Needle Driver Instrument) to manipulate the ablation probes during cardiac surgery can result 
- Feb 16, 2016 · Class II · Z-1191-2016: 
- Dec 5, 2014 · Class II · Z-0940-2015: Intuitive Surgical is initiating a voluntary correction related to da Vinci Si System (IS3000) Vision Side Carts, with threaded-in caster wheels, which can result in the caster wheel bolts gradually u
- May 21, 2014 · Class II · Z-1971-2014: Multiple updates to User Manuals, Instructions for Use (IFU), Quick Reference Guides (QRG), and Instrument Release Kits (IRK) for use with the da Vinci Surgical System, instruments and accessories. Re
- May 21, 2014 · Class II · Z-1967-2014: Multiple updates to User Manuals, Instructions for Use (IFU), Quick Reference Guides (QRG), and Instrument Release Kits (IRK) for use with the da Vinci Surgical System, instruments and accessories. Re
- May 21, 2014 · Class II · Z-1975-2014: Multiple updates to User Manuals, Instructions for Use (IFU), Quick Reference Guides (QRG), and Instrument Release Kits (IRK) for use with the da Vinci Surgical System, instruments and accessories. Re
- May 21, 2014 · Class II · Z-1966-2014: Multiple updates to User Manuals, Instructions for Use (IFU), Quick Reference Guides (QRG), and Instrument Release Kits (IRK) for use with the da Vinci Surgical System, instruments and accessories. Re
- May 21, 2014 · Class II · Z-1968-2014: Multiple updates to User Manuals, Instructions for Use (IFU), Quick Reference Guides (QRG), and Instrument Release Kits (IRK) for use with the da Vinci Surgical System, instruments and accessories. Re
- May 21, 2014 · Class II · Z-1964-2014: Multiple updates to User Manuals, Instructions for Use (IFU), Quick Reference Guides (QRG), and Instrument Release Kits (IRK) for use with the da Vinci Surgical System, instruments and accessories. Re
- May 21, 2014 · Class II · Z-1974-2014: Multiple updates to User Manuals, Instructions for Use (IFU), Quick Reference Guides (QRG), and Instrument Release Kits (IRK) for use with the da Vinci Surgical System, instruments and accessories. Re
- May 21, 2014 · Class II · Z-1969-2014: Multiple updates to User Manuals, Instructions for Use (IFU), Quick Reference Guides (QRG), and Instrument Release Kits (IRK) for use with the da Vinci Surgical System, instruments and accessories. Re
- May 21, 2014 · Class II · Z-1972-2014: Multiple updates to User Manuals, Instructions for Use (IFU), Quick Reference Guides (QRG), and Instrument Release Kits (IRK) for use with the da Vinci Surgical System, instruments and accessories. Re
- May 21, 2014 · Class II · Z-1973-2014: Multiple updates to User Manuals, Instructions for Use (IFU), Quick Reference Guides (QRG), and Instrument Release Kits (IRK) for use with the da Vinci Surgical System, instruments and accessories. Re
- May 21, 2014 · Class II · Z-1970-2014: Multiple updates to User Manuals, Instructions for Use (IFU), Quick Reference Guides (QRG), and Instrument Release Kits (IRK) for use with the da Vinci Surgical System, instruments and accessories. Re
- May 21, 2014 · Class II · Z-1965-2014: Multiple updates to User Manuals, Instructions for Use (IFU), Quick Reference Guides (QRG), and Instrument Release Kits (IRK) for use with the da Vinci Surgical System, instruments and accessories. Re
- Nov 11, 2013 · Class II · Z-0436-2014: Reports of friction within certain instrument arms can interrupt smooth instrument motion. This can be felt by the surgeon as resistance in the movement of the master.In this situation, the instrument
- Oct 21, 2013 · Class III · Z-0146-2014: Intuitive has identified that the metalized coating on the IS3000 HD lamp module may be incompatible with the illuminator control board, leading to an erroneous red Preventive Maintenance Message that
- Jun 8, 2013 · Class II · Z-1686-2013: Factory testing on da Vinci Si Surgical Systems may not be in compliance with UL Standards as one of the testing devices was found to be working incorrectly.
- Jun 8, 2013 · Class II · Z-1687-2013: Factory testing on da Vinci Si Surgical Systems may not be in compliance with UL Standards as one of the testing devices was found to be working incorrectly.
- Mar 15, 2013 · Class II · Z-1110-2013: Revised instructions for users of the da Vinci S, Si and Si-e systems with additional information regarding sterile adapter engagement and instrument installation.
- Apr 27, 2012 · Class II · Z-1994-2014: Patient Side Cart battery boxes may overheat in rare charging conditions, causing battery bulging.
- Feb 6, 2012 · Not classified · Z-1202-2012: The holding brake, a component of the da Vinci S Surgical System, may allow passive uncontrolled motion due to gravity during specific power-off conditions.
- Oct 17, 2011 · Class II · Z-0088-2014: Improper restraints during transportation of the da Vinci system could cause the HRSV Monitor to become loose from its mount.
- Nov 30, 12 · Class II · Z-0139-2014: Increased number of complaints regarding fluid entering the patient card base of the da Vinci S and SI systems.

## Indications for use
The Intuitive Surgical Endoscopic Instrument Control System (Intuitive Surgical® da Vinci Si Surgical System Model IS3000) is intended to assist in the accurate control of Intuitive Surgical Endoscopic Instruments including rigid endoscopes, blunt and sharp endoscopic dissectors, scissors, scalpels, ultrasonic shears, forceps/pick-ups, needle holders, endoscopic retractors, stabilizers, electrocautery and accessories for endoscopic manipulation of tissue, including grasping, cutting, blunt and sharp dissection, approximation, ligation, electrocautery, suturing, and delivery and placement of microwave and cryogenic ablation probes and accessories during urologic surgical procedures, general laparoscopic surgical procedures, gynecological laparoscopic surgical procedures, general cardiovascular and non-cardiovascular thoracoscopic surgical procedures, and thoracoscopically assisted cardiotomy procedures. The system is indicated for adult and pediatric use. The system can also be employed, with adjunctive mediastinotomy to perform coronary anastomosis during cardiac revascularization. It is intended for use by trained physicians in an operating room environment in accordance with the representative specific procedures set forth in the Professional Instructions for Use.