Pathfast CK-MB-II, Pathfast Myo-II

K081360510(k) TraditionalCleared Aug 17, 2009459-day reviewClass II21 CFR 862.1215Recalls 1

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Mitsubishi Kagaku Iatron · JHX Fluorometric Method, Cpk Or Isoenzymes

Cleared on Aug 17, 2009 after a 459-day review. FDA’s file for it is a 510(k) statement, which names no predicate. 1 later device descends from it. It has been recalled once.

Decided
Aug 17, 2009
Review
459 days
Class
Class II
Product code
JHX
Recalls
1
Predicates
0

1 later device descends from it, 1 citing it directly.

Descendants, by year cleared 2013: 1 descendant cleared20052010201520202025
  1. This deviceK081360 Pathfast CK-MB-II, Pathfast Myo-IIMitsubishi Kagaku Iatron · 2009
  2. Descendant · cites it directly · 0 of its ownK130628 Pathfast CK-MB-II CalibratorsMitsubishi Chemical Medience Corporation · 2013

Most influential descendants

Showing 1 of 1 · See all
  • K130628Pathfast CK-MB-II CalibratorsMitsubishi Chemical Medience Corporation · 2013 · cites it directly0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
0 (this device)K081360Pathfast CK-MB-II, Pathfast Myo-IIMitsubishi Kagaku Iatron2009—
+1K130628Pathfast CK-MB-II CalibratorsMitsubishi Chemical Medience Corporation2013—

Descendants by year cleared

Year clearedDevicesWith a Class I recall
201310
FIG. 1 — Lineage of K081360, 2009–2013Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA 510(k) statement (indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in JHX? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new JHX device

  1. #1 K234005 Access CK-MBscore 7.2 · 2 generations · no Class I recall
  2. #2 Held for the reportin the report
Get a 510(k) Report

What was it cleared against?

FDA’s file for it is a 510(k) statement, which names no predicate.

What descends from it? (1)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K130628Pathfast CK-MB-II CalibratorsMitsubishi Chemical Medience Corporation20130

Has anything in its family been recalled? (0 Class I)

Recalls of this device

DateClassRecallRoot causeReason
Apr 30, 2018Class IIZ-3185-2018Process controlA pinhole caused by the laser printer in the aluminum sheet over the ALP reagent wells caused leakage through the pinhole. If the cartridge with leakage is used, higher measurement value as low as +12% and no higher than +20% bias may be…

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • Of its descendants, K130628 (Mitsubishi Chemical Medience Corporation, 2013) has gone furthest, with 0 descendants of its own.

How does its category compare?

All JHX devices

JHX Fluorometric Method, Cpk Or Isoenzymes: FDA decisions, review times, recalls and adverse event reports over 20 years. 2009, this device’s year, is highlighted.

FDA decisions per year · JHX

1in 2024

2009: 12012: 12017: 12022: 12024: 1
2007high 1 (2009) · low 0 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · JHX

Too few JHX 510(k)s in any year since 2007 to give a median.

Recalls per year · JHX

2in 2015

2008: 12009: 12012: 42015: 2
2007high 4 (2012) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · JHX

1in 2025

2007: 22008: 62009: 402010: 272011: 42012: 182013: 82014: 172015: 82016: 102017: 32018: 162019: 72020: 32021: 102022: 22023: 22024: 22025: 1
2007high 40 (2009) · low 1 (2025)2025

MAUDE reports naming product code JHX, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—02
20080—16
20091—140
20100—027
20110—04
20121—418
20130—08
20140—017
20150—28
20160—010
20171—03
20180—016
20190—07
20200—03
20210—010
20221—02
20230—02
20241—02
20250—01
20260—0—

What is it indicated for?

PATHFAST CK-MB-Il test is an in vitro diagnostic test for the quantitative measurement of creatine kinase-MB in heparinized or EDTA whole blood and plasma. Measurements of CK-MB are used in the aid of diagnosis of acute myocardial infarction. This method is for use in clinical laboratory or point of care (POC) settings. The kit includes the reagent cartridges and calibrators. PATHFAST Myo-Il test is an in vitro diagnostic test for the quantitative…

Read the full statement (121 words)

PATHFAST CK-MB-Il test is an in vitro diagnostic test for the quantitative measurement of creatine kinase-MB in heparinized or EDTA whole blood and plasma. Measurements of CK-MB are used in the aid of diagnosis of acute myocardial infarction. This method is for use in clinical laboratory or point of care (POC) settings. The kit includes the reagent cartridges and calibrators.

PATHFAST Myo-Il test is an in vitro diagnostic test for the quantitative measurement of myoglobin in heparinized or EDTA whole blood and plasma. Measurements of myoglobin are used to assist in the aid of diagnosis of myocardial infarction (MI). This method is for use in clinical laboratory or point of care (POC) settings. The kit includes the reagent cartridges and calibrators.

Indications for use read by OCR from a scanned FDA 510(k) statement, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K081360: Pathfast CK-MB-II, Pathfast Myo-II.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 5, 2026. https://510kreport.com/device/K081360

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026