510(k) Report

510(k) · Cleared

Cleared

Glucocare Intensive Glycemic Control System

K081388510(k) TraditionalCleared Aug 21, 200894-day reviewClass II21 CFR 868.1890

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Pronia Medical System, LLC · NDC Calculator, Drug Dose

Cleared on Aug 21, 2008 as substantially equivalent to K053137 (MD Scientific, LLC, 2006) and 1 other predicate after a 94-day review. Its family tree reaches back 8 generations to 1994. 1 of the 35 devices in its family, counting itself, has a Class I recall.

Decided
Aug 21, 2008
Review
94 days
Class
Class II
Product code
NDC
Recalls
None
Predicates
2

Its longest line of descent runs back 8 generations to K941811 (1994). 34 ancestors in all, the oldest K822695 (1982). No later device cites it as a predicate yet. 1 of the 35 devices in this family, counting this one, has a Class I recall.

Other ancestors, by year cleared 2006: 1 other ancestor2001: 2 other ancestors2005: 2 other ancestors2004: 3 other ancestors, 1 with a Class I recall11998: 1 other ancestor2002: 2 other ancestors1992: 3 other ancestors2000: 1 other ancestor1999: 4 other ancestors1997: 2 other ancestors1993: 1 other ancestor1982: 1 other ancestor1996: 1 other ancestor1995: 1 other ancestor1994: 1 other ancestorK941811 · HP M1175A, M1176A, Component Monitoring System · Hewlett-Packard Co. · 1994K960934 · HP M1205A Omnicare Component Monitor System Model 24 · Hewlett-Packard Co. · 1996×2: 2 generations cleared close together, K981376 (1999), K990125 (1999) K992636 · HP Carevue 9000 Clinical Information System, Model M2331A · Hewlett-Packard Co. · 1999 · recalledK023674 · Philips Drug Calculator Software · Philips Medical Systems · 2002K061110 · Glucommander Plus · Collaborativemed, LLC · 2006K071713 · Clarian Glucose Stabilizer Insulin Dosing Calculator · Medical Decisions Network · 20071980198519901995200020052010
  1. Root · 8 generations backK941811 HP M1175A, M1176A, Component Monitoring SystemHewlett-Packard Co. · 1994
  2. 7 generations backK960934 HP M1205A Omnicare Component Monitor System Model 24Hewlett-Packard Co. · 1996
  3. 6 generations backK981376 Hewlett-Packard M1205A Viridia 24 CTHewlett-Packard Co. · 1999
  4. 5 generations backK990125 HP Viridia Component Monitoring System, Model Rev. KHewlett-Packard GmbH · 1999
  5. 4 generations backK992636 HP Carevue 9000 Clinical Information System, Model M2331AHewlett-Packard Co. · 1999 · Recalled
  6. 3 generations backK023674 Philips Drug Calculator SoftwarePhilips Medical Systems · 2002
  7. 2 generations backK061110 Glucommander PlusCollaborativemed, LLC · 2006
  8. 1 generation backK071713 Clarian Glucose Stabilizer Insulin Dosing CalculatorMedical Decisions Network · 2007
  9. This deviceK081388 Glucocare Intensive Glycemic Control SystemPronia Medical System, LLC · 2008

Class I recalls in this family

View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−8K941811HP M1175A, M1176A, Component Monitoring SystemHewlett-Packard Co.1994—
−7K960934HP M1205A Omnicare Component Monitor System Model 24Hewlett-Packard Co.1996—
−6K981376Hewlett-Packard M1205A Viridia 24 CTHewlett-Packard Co.1999—
−5K990125HP Viridia Component Monitoring System, Model Rev. KHewlett-Packard GmbH1999—
−4K992636HP Carevue 9000 Clinical Information System, Model M2331AHewlett-Packard Co.19998
−3K023674Philips Drug Calculator SoftwarePhilips Medical Systems2002—
−2K061110Glucommander PlusCollaborativemed, LLC2006—
−1K071713Clarian Glucose Stabilizer Insulin Dosing CalculatorMedical Decisions Network2007—
0 (this device)K081388Glucocare Intensive Glycemic Control SystemPronia Medical System, LLC2008—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
198210
199230
199310
199410
199510
199610
199720
199810
199940
200010
200120
200220
200431
200520
200610
FIG. 1 — Lineage of K081388, 1994–2008Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

1 device in this family has a Class I recall. A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new NDC device

  1. #1 K242775 InPen System App (MMT-8060 (iOS), MMT-8061…score 18.0 · 10 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (2)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K053137Endotool Drug Dose Calculator
Summary page 1
…ation: Class II (per 21 CFR 868.1890) Product Code: NDC 3. PREDICATE DEVICES * EndoToolTm Glucose Management System, K053 137 * MDN-CGSTM Insulin Dosing Calculator, K07 1713 4. DEVICE DESCRIPTION The GlucoCare IGC System is a software p…
MD Scientific, LLC2006—
*K071713Clarian Glucose Stabilizer Insulin Dosing Calculator
Summary page 1
…Product Code: NDC 3. PREDICATE DEVICES * EndoToolTm Glucose Management System, K053 137 * MDN-CGSTM Insulin Dosing Calculator, K07 1713 4. DEVICE DESCRIPTION The GlucoCare IGC System is a software program that implements an insulin infusion protocol…
Medical Decisions Network2007—

Also cleared against K053137: 2 other devices →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (1 Class I)

No FDA recall names this device.

Relatives with a Class I recall

Class I is FDA’s most serious recall class. A recall in the family tree is context for this device, not evidence about it.

  • K042873Animas Model IR1250 Insulin Infusion PumpAnimas Corp. · 2004 · 3 generations back · ◆ in the 2004 ancestors bar of FIG. 11 Class I recall

What does this lineage say?

  • The line of descent spans 14 years and passes through 6 companies; a new generation was cleared every 2.1 years on median.
  • 6 of the 34 ancestors have a recall of any class; 1 has a Class I recall.
  • 2 other devices also cite its predicate K053137.

How does its category compare?

All NDC devices

NDC Calculator, Drug Dose: FDA decisions, review times, recalls and adverse event reports over 20 years. 2008, this device’s year, is highlighted.

FDA decisions per year · NDC

2in 2025

2007: 12008: 22010: 12012: 22014: 32015: 32016: 22017: 82018: 32019: 12020: 52021: 32023: 32024: 32025: 22026 (partial year): 4
2007high 8 (2017) · low 0 (2009)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · NDC

60in 2024

2014: 118 days median2015: 199 days median2017: 189 days median2018: 220 days median2020: 53 days median2021: 269 days median2023: 126 days median2024: 60 days median2026 (partial year): 90 days median
2007high 269 (2021) · low 53 (2020)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · NDC

1in 2025

2016: 12017: 22018: 12019: 12022: 12025: 12026 (partial year): 2
2007high 2 (2017) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · NDC

299in 2025

2008: 72009: 42010: 182011: 112012: 22013: 12014: 12015: 12016: 182017: 252018: 212019: 182020: 102021: 112022: 3472023: 4632024: 1682025: 299
2007high 463 (2023) · low 0 (2007)2025

MAUDE reports naming product code NDC, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20071—00
20082—07
20090—04
20101—018
20110—011
20122—02
20130—01
2014311801
2015319901
20162—118
20178189225
20183220121
20191—118
2020553010
20213269011
20220—1347
202331260463
20243600168
20252—1299
20264902—

What is it indicated for?

The GlucoCare IGC System is a software program indicated for the management of patient blood glucose levels in the hospital setting. The GlucoCare IGC System software, using an algorithm that is based on an established clinical protocol, calculates the dosage of intravenously administered insulin required to maintain the blood glucose level within a target range set by the protocol. No medical decisions are made by the GlucoCare IGC System software. The…

Read the full statement (123 words)

The GlucoCare IGC System is a software program indicated for the management of patient blood glucose levels in the hospital setting. The GlucoCare IGC System software, using an algorithm that is based on an established clinical protocol, calculates the dosage of intravenously administered insulin required to maintain the blood glucose level within a target range set by the protocol. No medical decisions are made by the GlucoCare IGC System software. The information provided by the software is intended to be used as a tool by qualified and trained medical personnel. The GlucoCare IGC System software is intended for use in patients over the age of 18 with no known insulin allergies. The device is not intended for use in patients with diabetic ketoacidosis.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K081388: Glucocare Intensive Glycemic Control System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K081388

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026