510(k) Report

510(k) · Cleared

Cleared

Elekta Neuromag with Maxwell Filter with Internal Active Shielding

K081430510(k) SpecialCleared Jul 28, 200868-day reviewClass II21 CFR 882.1400

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Elekta Neuromag OY · OLX Source Localization Software For Electroencephalograph Or Magnetoencephalograph

Cleared on Jul 28, 2008 as substantially equivalent to K041264 (Elekta Neuromag OY, 2004) and 1 other predicate after a 68-day review. Its family tree reaches back 6 generations to 1990.

Decided
Jul 28, 2008
Review
68 days
Class
Class II
Product code
OLX
Recalls
None
Predicates
2

Its longest line of descent runs back 6 generations to K901215 (1990). No later device cites it as a predicate yet.

  1. Root · 6 generations backK901215 700 Series BiomagnetometerBiomagnetic Technologies, Inc. · 1990
  2. 5 generations backK962764 Neuromag-122Philips Medical Systems (Cleveland), Inc. · 1996
  3. 4 generations backK971329 CTF Systems Inc, Whole-Cortex Meg System (with Optional Eeg Subsystem)Ctf Systems, Inc. · 1997
  4. 3 generations backK030737 Omega Whole-Cortex MFG System, Models Omega 151, Omega 275Ctf Systems (2001), Inc. · 2003
  5. 2 generations backK041264 Elekta OYElekta Neuromag OY · 2004
  6. 1 generation backK050035 Elekta Neuromag with Maxwell FilterElekta Neuromag OY · 2005
  7. This deviceK081430 Elekta Neuromag with Maxwell Filter with Internal Active ShieldingElekta Neuromag OY · 2008
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−6K901215700 Series BiomagnetometerBiomagnetic Technologies, Inc.1990—
−5K962764Neuromag-122Philips Medical Systems (Cleveland), Inc.1996—
−4K971329CTF Systems Inc, Whole-Cortex Meg System (with Optional Eeg Subsystem)Ctf Systems, Inc.1997—
−3K030737Omega Whole-Cortex MFG System, Models Omega 151, Omega 275Ctf Systems (2001), Inc.2003—
−2K041264Elekta OYElekta Neuromag OY2004—
−1K050035Elekta Neuromag with Maxwell FilterElekta Neuromag OY2005—
0 (this device)K081430Elekta Neuromag with Maxwell Filter with Internal Active ShieldingElekta Neuromag OY2008—
FIG. 1 — Lineage of K081430, 1990–2008Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in OLX? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new OLX device

  1. #1 K260563 CN-Suite™score 14.0 · 8 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (2)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K041264Elekta OY
Summary page 1
…alograph, product code GWQ, Regulation: 882.1400 Class of device: ClassI1. ) y | a_l.{ The legally marketed device to which we are claiming equivalence (807.92(a)(3)} : K041264, Elekta Neuromag™, manufactured by Elekta Neuromag Oy and K050035, Elekta Neuromag® with Maxwell Filter. Description of device:…
Elekta Neuromag OY2004—
*K050035Elekta Neuromag with Maxwell Filter
Summary page 1
…ClassI1. ) y | a_l.{ The legally marketed device to which we are claiming equivalence (807.92(a)(3)} : K041264, Elekta Neuromag™, manufactured by Elekta Neuromag Oy and K050035, Elekta Neuromag® with Maxwell Filter. Description of device: This premarket notification represents modifications made to our c…
Elekta Neuromag OY2005—

Also cleared against K041264: 5 other devices →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 18 years and passes through 5 companies; a new generation was cleared every 3.5 years on median.
  • None of the 6 ancestors has a recall.
  • 5 other devices also cite its predicate K041264.

How does its category compare?

All OLX devices

OLX Source Localization Software For Electroencephalograph Or Magnetoencephalograph: FDA decisions, review times, recalls and adverse event reports over 20 years. 2008, this device’s year, is highlighted.

FDA decisions per year · OLX

1in 2025

2007: 12008: 12010: 32018: 12020: 12021: 12024: 22025: 12026 (partial year): 2
2007high 3 (2010) · low 0 (2009)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · OLX

462in 2010

2010: 462 days median
2007high 462 (2010)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · OLX

No recall names OLX since 2007.

Adverse event reports per year · OLX

1in 2015

2014: 12015: 1
2007high 1 (2014) · low 0 (2007)2025

MAUDE reports naming product code OLX, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20071—00
20081—00
20090—00
2010346200
20110—00
20120—00
20130—00
20140—01
20150—01
20160—00
20170—00
20181—00
20190—00
20201—00
20211—00
20220—00
20230—00
20242—00
20251—00
20262—0—

What is it indicated for?

Elekta Neuromag® with active shielding non-invasively measures the magnetoencephalographic (MEGQ) signals (and, optionally, electroencephalographic (EEG) signals) produced by electrically active tissue of the brain. These signals are recorded by a computerized data acquisition system, displayed and may then be interpreted by trained physicians to help localize these active areas. The locations may then be correlated with anatomical information of the…

Read the full statement (120 words)

Elekta Neuromag® with active shielding non-invasively measures the magnetoencephalographic (MEGQ) signals (and, optionally, electroencephalographic (EEG) signals) produced by electrically active tissue of the brain. These signals are recorded by a computerized data acquisition system, displayed and may then be interpreted by trained physicians to help localize these active areas. The locations may then be correlated with anatomical information of the brain. MEG is routinely used to identify the locations of visual, auditory, somatosensory, and motor cortex in the brain when used in conjunction with evoked response averaging dcvices. MEG is also used to non-invasively locate regions of epileptic activity within the brain. The localization information provided by MEG may be used, in conjunction with other diagnostic data, in ncurosurgical planning.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K081430: Elekta Neuromag with Maxwell Filter with Internal Active Shielding.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 5, 2026. https://510kreport.com/device/K081430

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026