510(k) Report

510(k) · Cleared

Cleared

Vascutek Cannula Graft, Model CGS2008S

K081560510(k) TraditionalCleared Feb 10, 2009252-day reviewClass II21 CFR 870.4210

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Vascutek, Ltd. · DWF Catheter, Cannula And Tubing, Vascular, Cardiopulmonary Bypass

Cleared on Feb 10, 2009 as substantially equivalent to K934127 (3M Health Care, Sarns, 1994) and 1 other predicate after a 252-day review. Its family tree reaches back 1 generation to 1994. 1 later device descends from it.

Decided
Feb 10, 2009
Review
252 days
Class
Class II
Product code
DWF
Recalls
None
Predicates
2

Its longest line of descent runs back 1 generation to K934127 (1994). 2 ancestors in all. 1 later device descends from it, 1 citing it directly.

Other ancestors, by year clearedDescendants, by year cleared 2004: 1 other ancestor2021: 1 descendant clearedK934127 · Sarns Low Jetting Aortic Arch Cannula · 3M Health Care, Sarns · 1994 · recalled1990200020102020
Other ancestors, by generationDescendants, by generation 1 generation back: 1 other ancestor 1 generation forward: 1 descendant K934127 · Sarns Low Jetting Aortic Arch Cannula · 3M Health Care, Sarns · 1994 · recalled0
  1. Root · 1 generation backK934127 Sarns Low Jetting Aortic Arch Cannula3M Health Care, Sarns · 1994 · Recalled
  2. This deviceK081560 Vascutek Cannula Graft, Model CGS2008SVascutek, Ltd. · 2009
  3. Descendant · cites it directly · 0 of its ownK203057 Quantum Perfusion Arterial Cannula GraftQura S.R.L · 2021

Most influential descendants

Showing 1 of 1 · See all
  • K203057Quantum Perfusion Arterial Cannula GraftQura S.R.L · 2021 · cites it directly0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−1K934127Sarns Low Jetting Aortic Arch Cannula3M Health Care, Sarns199441
0 (this device)K081560Vascutek Cannula Graft, Model CGS2008SVascutek, Ltd.2009—
+1K203057Quantum Perfusion Arterial Cannula GraftQura S.R.L2021—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
200410

Descendants by year cleared

Year clearedDevicesWith a Class I recall
202110
FIG. 1 — Lineage of K081560, 1994–2021Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in DWF? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new DWF device

  1. #1 K251258 MC2™ Two-Stage Venous Cannula; MC2X™…score 14.6 · 8 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (2)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K934127Sarns Low Jetting Aortic Arch Cannula
Summary page 1
…Name Date _____ Terumno Soft-Flow® Cardiopulmonary Class IIDWF 22nd February K934127 Cannula bypass vascular 1994 catheter, cannula,…
3M Health Care, Sarns199441
*K041528Modification to Eptfe Graft
Summary page 1
…catheter, cannula, or tubing Vascutek SEALPTFE Vascular graft, Class II DSY 14~September K041 528 Wrap graft prosthesis I ________2004 _____ Device Description: The Vascutek C…
Vascutek, Ltd.2004—

Also cleared against K934127: 4 other devices →

What descends from it? (1)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K203057Quantum Perfusion Arterial Cannula GraftQura S.R.L20210

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • 1 of the 2 ancestors has a recall of any class.
  • Of its descendants, K203057 (Qura S.R.L, 2021) has gone furthest, with 0 descendants of its own.
  • 4 other devices also cite its predicate K934127.

How does its category compare?

All DWF devices

DWF Catheter, Cannula And Tubing, Vascular, Cardiopulmonary Bypass: FDA decisions, review times, recalls and adverse event reports over 20 years. 2009, this device’s year, is highlighted.

FDA decisions per year · DWF

4in 2025

2007: 22008: 62009: 82010: 32011: 52012: 102013: 92014: 142015: 92016: 32017: 52018: 52019: 32020: 32021: 52022: 22023: 22024: 32025: 42026 (partial year): 8
2007high 14 (2014) · low 2 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · DWF

89in 2025

2008: 95 days median2009: 148 days median2010: 62 days median2011: 85 days median2012: 110 days median2013: 110 days median2014: 110 days median2015: 46 days median2016: 32 days median2017: 127 days median2018: 30 days median2019: 120 days median2020: 30 days median2021: 358 days median2024: 29 days median2025: 89 days median2026 (partial year): 81 days median
2007high 358 (2021) · low 29 (2024)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · DWF

4in 2024

2007: 252008: 252009: 212010: 262011: 132012: 372013: 14, 1 Class I2014: 62015: 3, 1 Class I2016: 32017: 2, 1 Class I2018: 102019: 22021: 32024: 42026 (partial year): 20
2007high 37 (2012) · low 0 (2020)2026

Class I (3 since 2007) Class II/III not classified

Adverse event reports per year · DWF

1,020in 2025

2007: 1212008: 1262009: 992010: 1972011: 2122012: 2332013: 2382014: 3252015: 2182016: 1442017: 1012018: 1182019: 1792020: 1422021: 1622022: 2762023: 4702024: 4012025: 1,020
2007high 1,020 (2025) · low 99 (2009)2025

MAUDE reports naming product code DWF, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20072—25121
200869525126
200981482199
201036226197
201158513212
20121011037233
2013911014 (1)238
2014141106325
20159463 (1)218
20163323144
201751272 (1)101
201853010118
201931202179
20203300142
202153583162
20222—0276
20232—0470
20243294401
202548901,020
202688120—

What is it indicated for?

This device is intended to be used in axillary arterial perfusion during cardiopulmonary bypass procedures. These devices are indicated for up to 6 hours of use.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K081560: Vascutek Cannula Graft, Model CGS2008S.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K081560

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026