510(k) · Cleared
ClearedModification to Single Planar Multi Axis (Spma) Pedicle Screw System
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Trinity Orthopedics, LLC · MNI Orthosis, Spinal Pedicle Fixation
Cleared on Jul 24, 2008 after a 29-day review. The FDA summary names its predicate without a number.
- Decided
- Jul 24, 2008
- Review
- 29 days
- Class
- Class II
- Product code
- MNI
- Recalls
- None
- Predicates
- 0
The FDA summary names its predicate without a number.
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in MNI? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
- Candidate predicates for a device like this, rankedin the report
- Recall history across each candidate’s familyin the report
What was it cleared against? (1)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | — | unmodified predicate SPMA Pedicle Screw System Named without a submission number |
What descends from it?
No later submission names this one as a predicate yet.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
How does its category compare?
All MNI devicesMNI Orthosis, Spinal Pedicle Fixation: FDA decisions, review times, recalls and adverse event reports over 20 years. 2008, this device’s year, is highlighted.
FDA decisions per year · MNI
1in 2017
2026 to Oct 25, outlined.
Median 510(k) review, days · MNI
168in 2016
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · MNI
1in 2018
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · MNI
80in 2025
MAUDE reports naming product code MNI, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 20 | 82 | 26 | 83 |
| 2008 | 23 | 64 | 8 | 108 |
| 2009 | 18 | 86 | 3 | 138 |
| 2010 | 16 | 74 | 1 | 126 |
| 2011 | 17 | 111 | 0 | 146 |
| 2012 | 19 | 75 | 1 | 200 |
| 2013 | 14 | 77 | 4 | 824 |
| 2014 | 6 | 104 | 0 | 301 |
| 2015 | 12 | 54 | 1 | 260 |
| 2016 | 7 | 168 | 0 | 117 |
| 2017 | 1 | — | 0 | 247 |
| 2018 | 0 | — | 1 | 134 |
| 2019 | 0 | — | 0 | 188 |
| 2020 | 0 | — | 0 | 115 |
| 2021 | 0 | — | 0 | 270 |
| 2022 | 0 | — | 0 | 214 |
| 2023 | 0 | — | 0 | 122 |
| 2024 | 0 | — | 0 | 114 |
| 2025 | 0 | — | 0 | 80 |
| 2026 | 0 | — | 0 | — |
What is it indicated for?
Trinity SPMA Pedicle Screw System is intended to provide immobilization and stabilization of spinal segments in skeletally mature patients as an adjunct to fusion in the treatment of the following acute and chronic instabilities or deformities of thoracic, lumbar, and sacral spine: degenerative spondylolisthesis with objective evidence of neurological impairment, fracture, spinal stenosis, dislocation, scoliosis, kyphosis, lordosis, spinal tumor, pseudoarthrosis, and failed previous fusion.
Indications for use as stated in the FDA summary.
https://510kreport.com/device/K081790 · printed Nov 6, 2026
Cite this page
510(k) Report. “K081790: Modification to Single Planar Multi Axis (Spma) Pedicle Screw System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K081790
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Page last updated Nov 3, 2026