510(k) Report

510(k) · Cleared

Cleared

Alco Tube Plus

K082080510(k) TraditionalCleared Apr 1, 2009252-day reviewClass I21 CFR 862.3050

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Alcotest Quebec · DJZ Devices, Breath Trapping, Alcohol

Cleared on Apr 1, 2009 as substantially equivalent to K060761 (Akers Biosciences, Inc., 2006) after a 252-day review. Its family tree reaches back 4 generations to 2004.

Decided
Apr 1, 2009
Review
252 days
Class
Class I
Product code
DJZ
Recalls
None
Predicates
1

Its longest line of descent runs back 4 generations to K041334 (2004). No later device cites it as a predicate yet.

  1. Root · 4 generations backK041334 Alcomate, Model CA2000Khn Solutions, LLC · 2004
  2. 3 generations backK043188 Alcohawk PrecisionQ3 Innovations, LLC · 2005
  3. 2 generations backK052448 Pocket Breathalyzer. ConnectablesConnectables, LLC · 2006
  4. 1 generation backK060761 Breathscan, Breath and Breath Check Alcohol DetectorsAkers Biosciences, Inc. · 2006
  5. This deviceK082080 Alco Tube PlusAlcotest Quebec · 2009
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−4K041334Alcomate, Model CA2000Khn Solutions, LLC2004—
−3K043188Alcohawk PrecisionQ3 Innovations, LLC2005—
−2K052448Pocket Breathalyzer. ConnectablesConnectables, LLC2006—
−1K060761Breathscan, Breath and Breath Check Alcohol DetectorsAkers Biosciences, Inc.2006—
0 (this device)K082080Alco Tube PlusAlcotest Quebec2009—
FIG. 1 — Lineage of K082080, 2004–2009Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in DJZ? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

  • Candidate predicates for a device like this, rankedin the report
  • Recall history across each candidate’s familyin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K060761Breathscan, Breath and Breath Check Alcohol Detectors
Summary page 1
…Device: Company Product 510(k) # Akers Biosciences, Inc. BreathScan® Alcohol Detector K060761 DEVICE DESCRIPTION 807.92(a)(4) The Alco Tube Plus Alcohol Detector (Tester) is a vis…
Akers Biosciences, Inc.2006—

Also cleared against K060761: 2 other devices →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 5 years and passes through 5 companies; a new generation was cleared every 1.0 years on median.
  • None of the 4 ancestors has a recall.
  • 2 other devices also cite its predicate K060761.

How does its category compare?

All DJZ devices

DJZ Devices, Breath Trapping, Alcohol: FDA decisions, review times, recalls and adverse event reports over 20 years. 2009, this device’s year, is highlighted.

FDA decisions per year · DJZ

1in 2016

2007: 22008: 52009: 52010: 22011: 32013: 12016: 1
2007high 5 (2008) · low 0 (2012)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · DJZ

240in 2011

2008: 149 days median2009: 122 days median2011: 240 days median
2007high 240 (2011) · low 122 (2009)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · DJZ

1in 2007

2007: 1
2007high 1 (2007) · low 0 (2008)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · DJZ

3in 2025

2007: 22011: 12019: 12022: 12023: 12025: 3
2007high 3 (2025) · low 0 (2008)2025

MAUDE reports naming product code DJZ, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20072—12
2008514900
2009512200
20102—00
2011324001
20120—00
20131—00
20140—00
20150—00
20161—00
20170—00
20180—00
20190—01
20200—00
20210—00
20220—01
20230—01
20240—00
20250—03
20260—0—

What is it indicated for?

The Alco Tube Plus Alcohol Detector is an in vitro medical device to qualitatively

detect the presence of alcohol in the human breath. It is a disposable screening

device for one-time use. The detector is available in two cut-offs including 0.05

and 0.08 percent breath alcohol. The device is used only as a screening device

.and is only an indication of the possible presence of alcohol in the blood of the

test subject.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K082080: Alco Tube Plus.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 5, 2026. https://510kreport.com/device/K082080

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026