510(k) · Cleared
ClearedCoulter Body Fluid Control
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Beckman Coulter, Inc. · JPK Mixture, Hematology Quality Control
Cleared on Feb 3, 2009 as substantially equivalent to K912133 (Coulter Electronics, Inc., 1991) and 1 other predicate after a 187-day review. Its family tree reaches back 2 generations to 1991.
- Decided
- Feb 3, 2009
- Review
- 187 days
- Class
- Class II
- Product code
- JPK
- Recalls
- None
- Predicates
- 2
Its longest line of descent runs back 2 generations to K912133 (1991). No later device cites it as a predicate yet.
View FIG. 1 as a table
Line of descent and top descendants
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in JPK? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
- Candidate predicates for a device like this, rankedin the report
- Recall history across each candidate’s familyin the report
What was it cleared against? (2)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K912133 | PX Coulter (R) Cell ControlSummary page 1…Number COULTER® Body COULTER® 5C® Beckman Coulter, Inc. K912133 Fluid Control Cell Control & (Cl… | 1991 |
| * | K060464 | Coulter 5C Cell ControlSummary page 1…Fluid Control Cell Control & (Cleared as K060464 COULTER® PX Cell Control) COULTER® Body Fluid Con… | 2006 |
What descends from it?
No later submission names this one as a predicate yet.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- The line of descent spans 18 years and passes through 2 companies; a new generation was cleared every 14.7 years on median.
- None of the 2 ancestors has a recall.
- 2 other devices also cite its predicate K912133.
How does its category compare?
All JPK devicesJPK Mixture, Hematology Quality Control: FDA decisions, review times, recalls and adverse event reports over 20 years. 2009, this device’s year, is highlighted.
FDA decisions per year · JPK
4in 2016
2026 to Oct 25, outlined.
Median 510(k) review, days · JPK
296in 2016
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · JPK
1in 2022
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · JPK
2in 2023
MAUDE reports naming product code JPK, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 5 | 44 | 1 | 14 |
| 2008 | 0 | — | 0 | 1 |
| 2009 | 5 | 187 | 0 | 0 |
| 2010 | 4 | 267 | 2 | 5 |
| 2011 | 1 | — | 3 | 56 |
| 2012 | 2 | — | 1 | 2 |
| 2013 | 1 | — | 0 | 0 |
| 2014 | 2 | — | 0 | 1 |
| 2015 | 0 | — | 0 | 0 |
| 2016 | 4 | 296 | 0 | 0 |
| 2017 | 0 | — | 0 | 0 |
| 2018 | 0 | — | 0 | 0 |
| 2019 | 0 | — | 0 | 1 |
| 2020 | 0 | — | 1 | 1 |
| 2021 | 0 | — | 2 | 1 |
| 2022 | 0 | — | 1 | 0 |
| 2023 | 0 | — | 0 | 2 |
| 2024 | 0 | — | 0 | 0 |
| 2025 | 0 | — | 0 | 0 |
| 2026 | 0 | — | 0 | — |
What is it indicated for?
Body Fluid Control is a hematology quality control material used to monitor the performance and verify the measuring range of the body fluid cycle of the UniCel® DxH 800 COULTER Cellular Analysis System. Refer to the System HELP or Instructions for Use.
The assigned values and expected ranges on the TABLE OF EXPECTED RESULTS can be used to monitor performance, and verify the measurable range. This product can also be used to establish your own laboratory mean.
Indications for use as stated in the FDA summary.
https://510kreport.com/device/K082162 · printed Nov 5, 2026
Cite this page
510(k) Report. “K082162: Coulter Body Fluid Control.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 5, 2026. https://510kreport.com/device/K082162
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026