510(k) · Cleared
ClearedIndependence Spacer
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Globus Medical, Inc. · OVD Intervertebral Fusion Device With Integrated Fixation, Lumbar
Cleared on Nov 5, 2008 as substantially equivalent to K072970 (Globus Medical, Inc., 2008) after an 89-day review. Its family tree reaches back 1 generation to 2008. 1 of the 578 devices in its family, counting itself, has a Class I recall. 576 later devices descend from it.
- Decided
- Nov 5, 2008
- Review
- 89 days
- Class
- Class II
- Product code
- OVD
- Recalls
- None
- Predicates
- 1
Its longest line of descent runs back 1 generation to K072970 (2008). 576 later devices descend from it, 13 citing it directly. 1 of the 578 devices in this family, counting this one, has a Class I recall.
- Root · 1 generation backK072970 Patriot SpacersGlobus Medical, Inc. · 2008
- This deviceK082252 Independence SpacerGlobus Medical, Inc. · 2008
- Descendant · cites it directly · 554 of its ownK103382 Intercontinental Plate-SpacerGlobus Medical, Inc. · 2011
- Descendant · 2 generations on · 466 of its ownK131723 Coroent Single Tab SystemNuvasive, Inc. · 2013
- Descendant · 2 generations on · 465 of its ownK140479 Coroent XL-F SystemNu Vasive, Incorporated · 2014
- Descendant · 3 generations on · 396 of its ownK160051 NuVasive® Interfixated Interbody SystemNu Vasive, Incorporated · 2016
- Descendant · 3 generations on · 390 of its ownK153782 NuVasive® Lumbar Interbody ImplantsNu Vasive, Incorporated · 2016
Showing 5 of 576 descendants. See all descendants
Descendants cleared per year
Class I recalls in this family
- K211616 ExcelsiusHub4 generations on · 2021
Most influential descendants
Showing 5 of 576 · See all- K103382Intercontinental Plate-SpacerGlobus Medical, Inc. · 2011 · cites it directly554descendants
- K131723Coroent Single Tab SystemNuvasive, Inc. · 2013 · 2 generations on466descendants
- K140479Coroent XL-F SystemNu Vasive, Incorporated · 2014 · 2 generations on465descendants
- K160051NuVasive® Interfixated Interbody SystemNu Vasive, Incorporated · 2016 · 3 generations on396descendants
- K153782NuVasive® Lumbar Interbody ImplantsNu Vasive, Incorporated · 2016 · 3 generations on390descendants
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −1 | K072970 | Patriot Spacers | Globus Medical, Inc. | 2008 | — |
| 0 (this device) | K082252 | Independence Spacer | Globus Medical, Inc. | 2008 | — |
| +1 | K103382 | Intercontinental Plate-Spacer | Globus Medical, Inc. | 2011 | — |
| +2 | K131723 | Coroent Single Tab System | Nuvasive, Inc. | 2013 | — |
| +2 | K140479 | Coroent XL-F System | Nu Vasive, Incorporated | 2014 | — |
| +3 | K160051 | NuVasive® Interfixated Interbody System | Nu Vasive, Incorporated | 2016 | — |
| +3 | K153782 | NuVasive® Lumbar Interbody Implants | Nu Vasive, Incorporated | 2016 | — |
Descendants by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 2011 | 1 | 0 |
| 2012 | 4 | 0 |
| 2013 | 4 | 0 |
| 2014 | 4 | 0 |
| 2015 | 4 | 0 |
| 2016 | 19 | 0 |
| 2017 | 27 | 0 |
| 2018 | 29 | 0 |
| 2019 | 36 | 0 |
| 2020 | 56 | 0 |
| 2021 | 49 | 1 |
| 2022 | 61 | 0 |
| 2023 | 69 | 0 |
| 2024 | 84 | 0 |
| 2025 | 70 | 0 |
| 2026 | 59 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
1 device in this family has a Class I recall. A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new OVD device
- #1 K222009 aprevo® anterior lumbar interbody fusion…score 26.0 · 23 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (1)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K072970 | Patriot SpacersSummary page 1…Device Name: INDEPENDENCE™ Spacer Classification: Product Code MAX. Class Il. 21 CFR §888.3080 Intervertebral body fusion device. Predicate(s): PATRIOT Lumbar Spacers (K072970) and other legally marketed devices. Device Description: The INDEPENDENCE™ Spacer is a stand-alone anterior lumbar interbody fu… | 2008 |
What descends from it? (576)
See all 57613 later devices cite it directly; ranked here by how many devices descend from each in turn.
| Number | Device | Decided | Descendants |
|---|---|---|---|
| K103382 | Intercontinental Plate-Spacer | 2011 | 554 |
| K120101 | Independence Spacer | 2012 | 224 |
| K143578 | SUSTAIN R TPS Spacers, PATRIOT TPS Spacers, CALIBER TPS Spacer, COALITION TPS Spacers… | 2016 | 210 |
| K142498 | MAGNIFY and MAGNIFY-S Spacers | 2015 | 175 |
| K132559 | Monument Spacers | 2013 | 166 |
| K152022 | SUSTAIN® R Spacers, PATRIOT® Spacers, CALIBER® Spacers, RISE® Spacers, COALITION®… | 2017 | 149 |
| K160597 | INDEPENDENCE MIS Spacers | 2016 | 111 |
| K170157 | INDEPENDENCE® Spacers | 2017 | 109 |
| K203278 | INDEPENDENCE Spacers, HEDRON IA, MAGNIFY-S Spacers, MONUMENT Spacers, InterContinental… | 2021 | 35 |
| K112561 | Nuvasive Coroent NO-Profile System | 2012 | 12 |
Has anything in its family been recalled? (1 Class I)
No FDA recall names this device.
Relatives with a Class I recall
Class I is FDA’s most serious recall class. A recall in the family tree is context for this device, not evidence about it.
- K211616ExcelsiusHubGlobus Medical, Inc. · 2021 · 4 generations on · ◆ in the 2021 descendants bar of FIG. 11 Class I recall
What does this lineage say?
How does its category compare?
All OVD devicesOVD Intervertebral Fusion Device With Integrated Fixation, Lumbar: FDA decisions, review times, recalls and adverse event reports over 20 years. 2008, this device’s year, is highlighted.
FDA decisions per year · OVD
10in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · OVD
100in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · OVD
1in 2025
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · OVD
50in 2025
MAUDE reports naming product code OVD, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 2 | — | 0 | 0 |
| 2008 | 8 | 84 | 0 | 0 |
| 2009 | 3 | 152 | 0 | 2 |
| 2010 | 8 | 117 | 0 | 2 |
| 2011 | 9 | 167 | 0 | 6 |
| 2012 | 10 | 78 | 0 | 16 |
| 2013 | 11 | 137 | 4 | 17 |
| 2014 | 14 | 139 | 0 | 35 |
| 2015 | 12 | 166 | 0 | 43 |
| 2016 | 13 | 127 | 1 | 55 |
| 2017 | 12 | 127 | 0 | 72 |
| 2018 | 14 | 126 | 0 | 112 |
| 2019 | 12 | 91 | 0 | 171 |
| 2020 | 14 | 91 | 0 | 203 |
| 2021 | 7 | 108 | 1 | 221 |
| 2022 | 14 | 133 | 1 | 74 |
| 2023 | 12 | 92 | 0 | 67 |
| 2024 | 12 | 110 | 0 | 92 |
| 2025 | 10 | 100 | 1 | 50 |
| 2026 | 8 | 93 | 1 | — |
What is it indicated for?
The INDEPENDENCE™ Spacer is a stand-alone interbody fusion device intended for use in patients with degenerative disc disease (DDD) at one or two contiguous levels of the lumbosacral spine (L2-S1). DDD is defined as discogenic back pain with degeneration of the disc confirmed by history and radiographic studies. These patients should be skeletally mature and have had at least six (6) months of non-operative treatment. In addition, these patients may have up to Grade 1 spondylolisthesis or retrolisthesis at the involved level(s). The INDEPENDENCE™ Spacer is to be filled with autogenous bone graft material, and is to be used with three titanium alloy screws which accompany the implant.
Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.
https://510kreport.com/device/K082252 · printed Nov 6, 2026
Cite this page
510(k) Report. “K082252: Independence Spacer.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K082252
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026