510(k) · Cleared
ClearedCambria
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Seaspine, Inc. · ODP Intervertebral Fusion Device With Bone Graft, Cervical
Cleared on Apr 9, 2009 after a 239-day review. The FDA summary names no predicate by number. 201 later devices descend from it.
- Decided
- Apr 9, 2009
- Review
- 239 days
- Class
- Class II
- Product code
- ODP
- Recalls
- None
- Predicates
- 0
201 later devices descend from it, 3 citing it directly.
- This deviceK082309 CambriaSeaspine, Inc. · 2009
- Descendant · cites it directly · 168 of its ownK092521 ZUMA-CSeaspine, Inc. · 2010
- Descendant · 2 generations on · 131 of its ownK102547 Coroent Interlock SystemNuvasive, Inc. · 2011
- Descendant · cites it directly · 116 of its ownK142488 SeaSpine Spacer System - (Hollywood, Pacifica, Redondo, Ventura)…Seaspine, Inc. · 2014
- Descendant · 2 generations on · 103 of its ownK162715 SeaSpine Spacer System- Hollywood NanoMetalene, Hollywood VI…SeaSpine Orthopedics Corporation · 2016
- Descendant · 3 generations on · 99 of its ownK142299 CoRoent Small Interlock SystemNu Vasive, Incorporated · 2014
Showing 5 of 201 descendants. See all descendants
Descendants cleared per year
Most influential descendants
Showing 5 of 201 · See all- K092521ZUMA-CSeaspine, Inc. · 2010 · cites it directly168descendants
- K102547Coroent Interlock SystemNuvasive, Inc. · 2011 · 2 generations on131descendants
- K142488SeaSpine Spacer System - (Hollywood, Pacifica, Redondo, Ventura) NanoMetalene, Cambria…Seaspine, Inc. · 2014 · cites it directly116descendants
- K162715SeaSpine Spacer System- Hollywood NanoMetalene, Hollywood VI NanoMetalene, Ventura…SeaSpine Orthopedics Corporation · 2016 · 2 generations on103descendants
- K142299CoRoent Small Interlock SystemNu Vasive, Incorporated · 2014 · 3 generations on99descendants
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| 0 (this device) | K082309 | Cambria | Seaspine, Inc. | 2009 | — |
| +1 | K092521 | ZUMA-C | Seaspine, Inc. | 2010 | — |
| +2 | K102547 | Coroent Interlock System | Nuvasive, Inc. | 2011 | — |
| +1 | K142488 | SeaSpine Spacer System - (Hollywood, Pacifica, Redondo, Ventura) NanoMetalene… | Seaspine, Inc. | 2014 | — |
| +2 | K162715 | SeaSpine Spacer System- Hollywood NanoMetalene, Hollywood VI NanoMetalene… | SeaSpine Orthopedics Corporation | 2016 | — |
| +3 | K142299 | CoRoent Small Interlock System | Nu Vasive, Incorporated | 2014 | — |
Descendants by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 2010 | 1 | 0 |
| 2011 | 2 | 0 |
| 2013 | 1 | 0 |
| 2014 | 2 | 0 |
| 2015 | 2 | 0 |
| 2016 | 6 | 0 |
| 2017 | 10 | 0 |
| 2018 | 8 | 0 |
| 2019 | 8 | 0 |
| 2020 | 11 | 0 |
| 2021 | 15 | 0 |
| 2022 | 22 | 0 |
| 2023 | 28 | 0 |
| 2024 | 29 | 0 |
| 2025 | 34 | 0 |
| 2026 | 22 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in ODP? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new ODP device
- #1 K222276 CONDUIT Cages; FIBERGRAFT BG Puttyscore 53.4 · 25 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against?
The FDA summary names no predicate by number.
What descends from it? (201)
See all 2013 later devices cite it directly; ranked here by how many devices descend from each in turn.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- Of its descendants, K092521 (Seaspine, Inc., 2010) has gone furthest, with 168 descendants of its own.
How does its category compare?
All ODP devicesODP Intervertebral Fusion Device With Bone Graft, Cervical: FDA decisions, review times, recalls and adverse event reports over 20 years. 2009, this device’s year, is highlighted.
FDA decisions per year · ODP
11in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · ODP
87in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · ODP
2in 2025
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · ODP
57in 2025
MAUDE reports naming product code ODP, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 0 | — | 0 | 0 |
| 2008 | 8 | 89 | 0 | 2 |
| 2009 | 12 | 127 | 1 | 21 |
| 2010 | 9 | 151 | 0 | 54 |
| 2011 | 25 | 113 | 1 | 38 |
| 2012 | 17 | 93 | 0 | 92 |
| 2013 | 18 | 187 | 1 | 78 |
| 2014 | 26 | 118 | 0 | 43 |
| 2015 | 24 | 180 | 0 | 51 |
| 2016 | 17 | 112 | 0 | 37 |
| 2017 | 33 | 104 | 0 | 39 |
| 2018 | 25 | 133 | 0 | 51 |
| 2019 | 22 | 92 | 0 | 141 |
| 2020 | 14 | 89 | 1 | 86 |
| 2021 | 18 | 121 | 0 | 161 |
| 2022 | 12 | 92 | 0 | 50 |
| 2023 | 34 | 165 | 0 | 36 |
| 2024 | 10 | 76 | 0 | 55 |
| 2025 | 11 | 87 | 2 | 57 |
| 2026 | 19 | 117 | 0 | — |
What is it indicated for?
Cambria is intended to be used as an adjunct to spinal fusion procedures at one level (C3-C7) in
skeletally mature patients with degenerative disc disease (defined as neck pain with discogenic origin
with degeneration of the disc confirmed by history and radiographic studies) of the cervical spine.
Patients should have received at least six weeks of non-operative treatment prior to treatment with the
device. Devices are intended to be implanted via an open, anterior approach and used with autogenous
bone and supplemental fixation, such as an anterior plating system.
Indications for use as stated in the FDA summary.
https://510kreport.com/device/K082309 · printed Nov 5, 2026
Cite this page
510(k) Report. “K082309: Cambria.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 5, 2026. https://510kreport.com/device/K082309
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026