510(k) · Cleared
ClearedDSA 2000EX
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Eigen, LLC · LLZ System, Image Processing, Radiological
Cleared on Aug 29, 2008 as substantially equivalent to K901956 (Eigen, 1990) and 1 other predicate after a 14-day review. Its family tree reaches back 2 generations to 1990.
- Decided
- Aug 29, 2008
- Review
- 14 days
- Class
- Class II
- Product code
- LLZ
- Recalls
- None
- Predicates
- 2
Its longest line of descent runs back 2 generations to K901956 (1990). No later device cites it as a predicate yet.
View FIG. 1 as a table
Line of descent and top descendants
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in LLZ? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new LLZ device
- #1 K230955 syngo Application Softwarescore 21.5 · 11 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (2)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K901956 | Digital 8 W/Other Numerical Suffixes (1-9, Etc.)Summary page 1…21CFR 892.2050 Predicate Devices: Device Name 510(k) Number Digital 8 K901956 DSA 2000 K063846 Description of the Device and Summary of the Tec… | 1990 |
| * | K063846 | Eigen Dsa 2000Summary page 1…510(k) Number Digital 8 K901956 DSA 2000 K063846 Description of the Device and Summary of the Technological Characteristics The DSA 2000ex device is used in vascular imaging a… | 2007 |
What descends from it?
No later submission names this one as a predicate yet.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- The line of descent spans 18 years and passes through 2 companies; a new generation was cleared every 16.6 years on median.
- None of the 2 ancestors has a recall.
- 1 other device also cites its predicate K901956.
How does its category compare?
All LLZ devicesLLZ System, Image Processing, Radiological: FDA decisions, review times, recalls and adverse event reports over 20 years. 2008, this device’s year, is highlighted.
FDA decisions per year · LLZ
58in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · LLZ
173in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · LLZ
11in 2025
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · LLZ
116in 2025
MAUDE reports naming product code LLZ, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 76 | 36 | 20 | 152 |
| 2008 | 94 | 52 | 32 | 154 |
| 2009 | 70 | 62 | 21 | 145 |
| 2010 | 51 | 98 | 17 | 145 |
| 2011 | 106 | 79 | 30 | 454 |
| 2012 | 82 | 87 | 12 | 266 |
| 2013 | 95 | 84 | 64 | 1,130 |
| 2014 | 78 | 89 | 6 | 15,631 |
| 2015 | 64 | 90 | 16 | 211 |
| 2016 | 82 | 90 | 12 | 290 |
| 2017 | 78 | 107 | 5 | 104 |
| 2018 | 104 | 105 | 7 | 72 |
| 2019 | 74 | 107 | 2 | 88 |
| 2020 | 81 | 115 | 6 | 82 |
| 2021 | 83 | 116 | 3 | 70 |
| 2022 | 65 | 137 | 4 | 28 |
| 2023 | 87 | 157 | 8 | 26 |
| 2024 | 62 | 131 | 6 | 42 |
| 2025 | 58 | 173 | 11 | 116 |
| 2026 | 45 | 110 | 14 | — |
What is it indicated for?
The DSA 2000ex device is used in vascular imaging applications. During X-ray exposures, the DSA 2000ex is used to acquire video images from the video display chain provided by the X-ray manufacturer's system. The images are stored in the DSA 2000ex solid state memory, and written to the hard disk medium. Images are processed in real-time to provide increased image usability. The processing is primarily subtraction, but also includes window and level…
Read the full statement (139 words)
The DSA 2000ex device is used in vascular imaging applications. During X-ray exposures, the DSA 2000ex is used to acquire video images from the video display chain provided by the X-ray manufacturer's system. The images are stored in the DSA 2000ex solid state memory, and written to the hard disk medium. Images are processed in real-time to provide increased image usability. The processing is primarily subtraction, but also includes window and level adjustments, as well as optional noise reduction, landscaping, image rotation and pixel shifting. The Eigen DSA 2000ex device is used in X-ray cardiology and radiology labs to enhance diagnostic capabilities of radiologists and cardiologists, with minimal intervention required by users to perform basic capture, playback, and archiving functions. Additional functions include allowing measurements to be made for quantizing stenosis and guidance of catheters in the Roadmapping mode.
Indications for use as stated in the FDA summary.
https://510kreport.com/device/K082341 · printed Nov 4, 2026
Cite this page
510(k) Report. “K082341: DSA 2000EX.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K082341
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026