510(k) Report

510(k) · Cleared

Cleared

Stryker Compartmental Knee System Line Extension

K082567510(k) SpecialCleared Oct 3, 200829-day reviewClass II21 CFR 888.3530

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Howmedica Osteonics Corp. · HRY Prosthesis, Knee, Femorotibial, Semi-Constrained, Cemented, Metal/Polymer

Cleared on Oct 3, 2008 after a 29-day review. The FDA summary names no predicate by number. 10 later devices descend from it.

Decided
Oct 3, 2008
Review
29 days
Class
Class II
Product code
HRY
Recalls
None
Predicates
0

10 later devices descend from it, 1 citing it directly.

Descendants, by year cleared 2009: 1 descendant cleared2016: 1 descendant cleared2019: 2 descendants cleared2024: 3 descendants cleared2023: 1 descendant cleared2022: 1 descendant cleared2026: 1 descendant cleared20052010201520202025
  1. This deviceK082567 Stryker Compartmental Knee System Line ExtensionHowmedica Osteonics Corp. · 2008
  2. Descendant · cites it directly · 9 of its ownK093056 Smith & Nephew, Inc. Journey Select Knee SystemSmith & Nephew, Inc. · 2009
  3. Descendant · 2 generations on · 8 of its ownK160738 ZUK Select Knee SystemSmith & Nephew, Inc. · 2016
  4. Descendant · 3 generations on · 7 of its ownK190085 Journey II Unicompartmental Knee SystemSmith & Nephew, Inc. · 2019 · Recalled
  5. Descendant · 4 generations on · 3 of its ownK230653 Smith & Nephew, Inc. ANTHEM Total Knee System, Genesis Uni Knee…Smith & Nephew, Inc. · 2023 · Recalled
  6. Descendant · 3 generations on · 1 of its ownK191211 JOURNEY II Unicompartmental Knee SystemSmith & Nephew, Inc. · 2019

Showing 5 of 10 descendants. See all descendants

Descendants cleared per year

2009: 12016: 12019: 22022: 12023: 12024: 32026: 1
2009high 3 (2024) · low 0 (2010)2026

Most influential descendants

Showing 5 of 10 · See all
  • K093056Smith & Nephew, Inc. Journey Select Knee SystemSmith & Nephew, Inc. · 2009 · cites it directly9descendants
  • K160738ZUK Select Knee SystemSmith & Nephew, Inc. · 2016 · 2 generations on8descendants
  • K190085Journey II Unicompartmental Knee SystemSmith & Nephew, Inc. · 2019 · 3 generations on7descendants
  • K230653Smith & Nephew, Inc. ANTHEM Total Knee System, Genesis Uni Knee System, JOURNEY BCS and…Smith & Nephew, Inc. · 2023 · 4 generations on3descendants
  • K191211JOURNEY II Unicompartmental Knee SystemSmith & Nephew, Inc. · 2019 · 3 generations on1descendant
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
0 (this device)K082567Stryker Compartmental Knee System Line ExtensionHowmedica Osteonics Corp.2008—
+1K093056Smith & Nephew, Inc. Journey Select Knee SystemSmith & Nephew, Inc.2009—
+2K160738ZUK Select Knee SystemSmith & Nephew, Inc.2016—
+3K190085Journey II Unicompartmental Knee SystemSmith & Nephew, Inc.20193
+4K230653Smith & Nephew, Inc. ANTHEM Total Knee System, Genesis Uni Knee System…Smith & Nephew, Inc.20231
+3K191211JOURNEY II Unicompartmental Knee SystemSmith & Nephew, Inc.2019—

Descendants by year cleared

Year clearedDevicesWith a Class I recall
200910
201610
201920
202210
202310
202430
202610
FIG. 1 — Lineage of K082567, 2008–2026Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in HRY? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new HRY device

  1. #1 K193549 SIGMA High Performance (HP) Partial Knee Systemscore 0.4 · 5 generations · no Class I recall
Get a 510(k) Report

What was it cleared against?

The FDA summary names no predicate by number.

What descends from it? (10)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K093056Smith & Nephew, Inc. Journey Select Knee SystemSmith & Nephew, Inc.20099

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • Of its descendants, K093056 (Smith & Nephew, Inc., 2009) has gone furthest, with 9 descendants of its own.

How does its category compare?

All HRY devices

HRY Prosthesis, Knee, Femorotibial, Semi-Constrained, Cemented, Metal/Polymer: FDA decisions, review times, recalls and adverse event reports over 20 years. 2008, this device’s year, is highlighted.

FDA decisions per year · HRY

1in 2020

2007: 32008: 32010: 12011: 12012: 12013: 12014: 12015: 12016: 12019: 12020: 1
2007high 3 (2007) · low 0 (2009)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · HRY

138in 2008

2007: 92 days median2008: 138 days median
2007high 138 (2008) · low 92 (2007)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · HRY

3in 2022

2007: 12008: 12011: 12013: 12016: 12020: 12021: 12022: 3
2007high 3 (2022) · low 0 (2009)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · HRY

290in 2025

2007: 2632008: 2852009: 2492010: 1802011: 1552012: 1372013: 3832014: 3052015: 3452016: 3432017: 4022018: 6132019: 3672020: 1,0542021: 1,2182022: 8402023: 3962024: 4302025: 290
2007high 1,218 (2021) · low 137 (2012)2025

MAUDE reports naming product code HRY, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20073921263
200831381285
20090—0249
20101—0180
20111—1155
20121—0137
20131—1383
20141—0305
20151—0345
20161—1343
20170—0402
20180—0613
20191—0367
20201—11,054
20210—11,218
20220—3840
20230—0396
20240—0430
20250—0290
20260—0—

What is it indicated for?

The Stryker ® Compartmental Knee System line extension is intended for use in cemented patellofemoral and/or unicondylar arthroplasty in patients where conditions exist that cannot be addressed by a single device to treat the femorotibial or patellofemoral regions of the knee. The indications for the different components of the Stryker® Compartmental Knee System line extension include conditions when the patellofemoral and/or condylar region(s) have been…

Read the full statement (197 words)

The Stryker ® Compartmental Knee System line extension is intended for use in cemented patellofemoral and/or unicondylar arthroplasty in patients where conditions exist that cannot be addressed by a single device to treat the femorotibial or patellofemoral regions of the knee. The indications for the different components of the Stryker® Compartmental Knee System line extension include conditions when the patellofemoral and/or condylar region(s) have been affected by one or more of the following conditions:

* Degenerative arthritis in the distal femur and patella,

* Patients with a history of patellar dislocation or patella fracture,

* Patients with failed previous surgery (arthroscopy, tibial tubercle elevation, lateral release) where pain, deformity or dysfunction persists,

· Moderately disabling joint disease of the knee resulting from painful osteo- or post traumatic arthritis,

* Revision of previous unsuccessful surgical procedures, either involving, or not involving, previous use of a unicompartmental knee prosthesis,

* As an alternative to tibial osteotomy in patients with unicompartmental osteoarthritis, or

4 Where bone stock is of poor quality or inadequate for other reconstructive techniques as indicated by deficiencies of the femoral condyle/tibial plateau.

These components are single use only and are intended for implantation with bone cement.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K082567: Stryker Compartmental Knee System Line Extension.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K082567

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026