510(k) · Cleared
ClearedSynthes (Usa) 3.5MM LCP Posteromedial Proximal Tibia Plates
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Synthes (Usa) · HRS Plate, Fixation, Bone
Cleared on Nov 10, 2008 after a 62-day review. The FDA summary names its predicate without a number. 20 later devices descend from it.
- Decided
- Nov 10, 2008
- Review
- 62 days
- Class
- Class II
- Product code
- HRS
- Recalls
- None
- Predicates
- 0
20 later devices descend from it, 8 citing it directly.
- This deviceK082624 Synthes (Usa) 3.5MM LCP Posteromedial Proximal Tibia PlatesSynthes (Usa) · 2008
- Descendant · cites it directly · 8 of its ownK213864 Bonebridge Osteosynthesis Plating SystemBonebridge AG · 2022
- Descendant · 2 generations on · 7 of its ownK231292 TAMINA 3.5mm Proximal Humerus System; POYA 3.5MM Lateral Proximal…Bonebridge AG · 2023
- Descendant · 3 generations on · 4 of its ownK240318 SITTER 3.5mm Versatile SystemBonebridge AG · 2024
- Descendant · cites it directly · 3 of its ownK163383 GREENS BRAND Locking Bone Plates and Screws Osteosynthesis Plating…Greens Surgicals Pvt., Ltd. · 2017
- Descendant · 2 generations on · 2 of its ownK242939 ARTFX Trauma Bone Plate and Screw SystemArtfx Medical · 2024
Showing 5 of 20 descendants. See all descendants
Descendants cleared per year
Most influential descendants
Showing 5 of 20 · See all- K213864Bonebridge Osteosynthesis Plating SystemBonebridge AG · 2022 · cites it directly8descendants
- K231292TAMINA 3.5mm Proximal Humerus System; POYA 3.5MM Lateral Proximal Tibia System; LORRAINE…Bonebridge AG · 2023 · 2 generations on7descendants
- K240318SITTER 3.5mm Versatile SystemBonebridge AG · 2024 · 3 generations on4descendants
- K163383GREENS BRAND Locking Bone Plates and Screws Osteosynthesis Plating System, GREENS BRAND…Greens Surgicals Pvt., Ltd. · 2017 · cites it directly3descendants
- K242939ARTFX Trauma Bone Plate and Screw SystemArtfx Medical · 2024 · 2 generations on2descendants
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| 0 (this device) | K082624 | Synthes (Usa) 3.5MM LCP Posteromedial Proximal Tibia Plates | Synthes (Usa) | 2008 | — |
| +1 | K213864 | Bonebridge Osteosynthesis Plating System | Bonebridge AG | 2022 | — |
| +2 | K231292 | TAMINA 3.5mm Proximal Humerus System; POYA 3.5MM Lateral Proximal Tibia… | Bonebridge AG | 2023 | — |
| +3 | K240318 | SITTER 3.5mm Versatile System | Bonebridge AG | 2024 | — |
| +1 | K163383 | GREENS BRAND Locking Bone Plates and Screws Osteosynthesis Plating System… | Greens Surgicals Pvt., Ltd. | 2017 | — |
| +2 | K242939 | ARTFX Trauma Bone Plate and Screw System | Artfx Medical | 2024 | — |
Descendants by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 2017 | 1 | 0 |
| 2019 | 1 | 0 |
| 2020 | 1 | 0 |
| 2022 | 1 | 0 |
| 2023 | 1 | 0 |
| 2024 | 5 | 0 |
| 2025 | 3 | 0 |
| 2026 | 7 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in HRS? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new HRS device
- #1 K222465 Tyber Medical Anatomical Plating Systemscore 27.5 · 16 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (2)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | — | Synthes (USA) 3.5mm / 4.5mm LCP Metaphyseal Plates Named without a submission number | |
| * | — | Synthes (USA) Large Fragment LCP System T Plates Named without a submission number |
What descends from it? (20)
See all 208 later devices cite it directly; ranked here by how many devices descend from each in turn.
| Number | Device | Decided | Descendants |
|---|---|---|---|
| K213864 | Bonebridge Osteosynthesis Plating System | 2022 | 8 |
| K163383 | GREENS BRAND Locking Bone Plates and Screws Osteosynthesis Plating System, GREENS BRAND… | 2017 | 3 |
| K202489 | AOS Fibonacci Lower Extremity Plating System – AOS Proximal Tibia Plating System | 2020 | 2 |
| K242399 | Bonebridge Osteosynthesis Plating System | 2024 | 1 |
| K260069 | DePuy Synthes VOLT™ Proximal Tibia 3.5 Plating System | 2026 | 0 |
| K250155 | Xpert Knee | 2025 | 0 |
| K232115 | TDM Large Bone Plate and Screw System | 2024 | 0 |
| K190750 | DePuy Synthes Plates and Screws Portfolio | 2019 | 0 |
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- Of its descendants, K213864 (Bonebridge AG, 2022) has gone furthest, with 8 descendants of its own.
How does its category compare?
All HRS devicesHRS Plate, Fixation, Bone: FDA decisions, review times, recalls and adverse event reports over 20 years. 2008, this device’s year, is highlighted.
FDA decisions per year · HRS
54in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · HRS
90in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · HRS
1in 2025
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · HRS
2,306in 2025
MAUDE reports naming product code HRS, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 35 | 63 | 2 | 339 |
| 2008 | 35 | 87 | 11 | 311 |
| 2009 | 47 | 85 | 3 | 435 |
| 2010 | 49 | 100 | 16 | 491 |
| 2011 | 43 | 88 | 5 | 773 |
| 2012 | 59 | 106 | 4 | 1,663 |
| 2013 | 56 | 89 | 11 | 2,643 |
| 2014 | 76 | 57 | 0 | 2,413 |
| 2015 | 56 | 97 | 7 | 3,095 |
| 2016 | 44 | 109 | 5 | 2,276 |
| 2017 | 57 | 122 | 3 | 2,220 |
| 2018 | 40 | 116 | 2 | 2,663 |
| 2019 | 46 | 89 | 25 | 3,359 |
| 2020 | 48 | 88 | 1 | 2,790 |
| 2021 | 40 | 87 | 9 | 2,442 |
| 2022 | 47 | 144 | 3 | 1,700 |
| 2023 | 40 | 120 | 1 | 2,049 |
| 2024 | 54 | 96 | 0 | 1,849 |
| 2025 | 54 | 90 | 1 | 2,306 |
| 2026 | 51 | 82 | 3 | — |
What is it indicated for?
Synthes 3.5mm LCP Posteromedial Proximal Tibia Plates are indicated for internal fixation of posteromedial proximal tibia fractures including buttressing of fractures of the proximal, distal, and metaphyseal areas of the tibia.
Indications for use as stated in the FDA summary.
https://510kreport.com/device/K082624 · printed Nov 6, 2026
Cite this page
510(k) Report. “K082624: Synthes (Usa) 3.5MM LCP Posteromedial Proximal Tibia Plates.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K082624
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026