510(k) · Cleared
ClearedProtron Technologies, LLC Stethotron
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Protron Technologies, LLC · DQD Stethoscope, Electronic
Cleared on Feb 27, 2009 as substantially equivalent to K961848 (Minnesota Mining and Mfg. Co., 1997) after a 158-day review. Its family tree reaches back 2 generations to 1977.
- Decided
- Feb 27, 2009
- Review
- 158 days
- Class
- Class II
- Product code
- DQD
- Recalls
- None
- Predicates
- 1
Its longest line of descent runs back 2 generations to K771653 (1977). No later device cites it as a predicate yet.
View FIG. 1 as a table
Line of descent and top descendants
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in DQD? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new DQD device
- #1 K200776 Eko COREscore 25.2 · 8 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (1)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K961848 | 3M Littmann Electronic StethoscopeSummary page 1…C Electronic Stethoscope, Model Stethotron is substantial equivalent to the 3M Littman Electronic Stethoscope, Model 2000 cleared for market under Premarket Notification k961848. December 20, 2008 ProTron Technologies, LLC Electronic Stethoscope, Model Stethotron Submission to FDA… | 1997 |
What descends from it?
No later submission names this one as a predicate yet.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- The line of descent spans 32 years and passes through 3 companies; a new generation was cleared every 20.0 years on median.
- None of the 2 ancestors has a recall.
- 4 other devices also cite its predicate K961848.
How does its category compare?
All DQD devicesDQD Stethoscope, Electronic: FDA decisions, review times, recalls and adverse event reports over 20 years. 2009, this device’s year, is highlighted.
FDA decisions per year · DQD
3in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · DQD
89in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · DQD
No recall names DQD since 2007.
Adverse event reports per year · DQD
1in 2024
MAUDE reports naming product code DQD, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 2 | — | 0 | 0 |
| 2008 | 1 | — | 0 | 0 |
| 2009 | 6 | 161 | 0 | 0 |
| 2010 | 1 | — | 0 | 0 |
| 2011 | 4 | 107 | 0 | 1 |
| 2012 | 2 | — | 0 | 0 |
| 2013 | 5 | 70 | 0 | 1 |
| 2014 | 0 | — | 0 | 0 |
| 2015 | 2 | — | 0 | 0 |
| 2016 | 3 | 250 | 0 | 0 |
| 2017 | 4 | 109 | 0 | 0 |
| 2018 | 4 | 131 | 0 | 0 |
| 2019 | 4 | 262 | 0 | 0 |
| 2020 | 6 | 104 | 0 | 0 |
| 2021 | 4 | 137 | 0 | 0 |
| 2022 | 8 | 203 | 0 | 0 |
| 2023 | 10 | 132 | 0 | 0 |
| 2024 | 4 | 153 | 0 | 1 |
| 2025 | 3 | 89 | 0 | 0 |
| 2026 | 6 | 236 | 0 | — |
What is it indicated for?
The ProTron Technologies, Electronic Stethoscope, Model Stethotron is intended for medical diagnostic purpose only. Stethotron has two modes of operation, amplification with filtering (Mode 1) and amplification only (Mode 2). Mode 1 filters out sounds below 350 Hz and above 1,000 Hz and used to listen specifically for vascular pathology. Mode 2 is used to listen for heart, lung, arteries, and other body sounds from 20 Hz to 20,000 Hz during routine physical examinations. Stethotron can be used on adult or paediatric patients undergoing physical examination.
Indications for use as stated in the FDA summary.
https://510kreport.com/device/K082771 · printed Nov 4, 2026
Cite this page
510(k) Report. “K082771: Protron Technologies, LLC Stethotron.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K082771
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026