510(k) · Cleared
ClearedStar/Vent Internal Hex Screw Implant
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Park Dental Research Corp. · DZE Implant, Endosseous, Root-Form
Cleared on Aug 26, 2010 as substantially equivalent to K063364 (Alpha-Bio Tec, Ltd., 2007) and 3 other predicates after a 701-day review. Its family tree reaches back 10 generations to 1996.
- Decided
- Aug 26, 2010
- Review
- 701 days
- Class
- Class II
- Product code
- DZE
- Recalls
- None
- Predicates
- 5
Its longest line of descent runs back 10 generations to K960026 (1996). 76 ancestors in all, the oldest K874590 (1988). No later device cites it as a predicate yet.
- Root · 10 generations backK960026 Biohorizons Dental Implant SystemBioHorizons Implant Systems, Inc. · 1996
- 6 generations between
- 3 generations backK032351 The Maestro System 3.0MM Diameter ImplantBioHorizons Implant Systems, Inc. · 2003
- 2 generations backK041938 Maximus OS (Overdenture System)BioHorizons Implant Systems, Inc. · 2004 · Recalled
- 1 generation backK063364 Alpha Bio Dental Implant SystemAlpha-Bio Tec, Ltd. · 2007
- This deviceK082800 Star/Vent Internal Hex Screw ImplantPark Dental Research Corp. · 2010
Show all 10 generations
- Root · 10 generations backK960026 Biohorizons Dental Implant SystemBioHorizons Implant Systems, Inc. · 1996
- 9 generations backK964330 Biohorizons Dental Implant System (Name Subject to Change)BioHorizons Implant Systems, Inc. · 1997
- 8 generations backK972313 The Maestro SystemBioHorizons Implant Systems, Inc. · 1997
- 7 generations backK020133 Modification to the Maestro SystemBioHorizons Implant Systems, Inc. · 2002
- 6 generations backK020645 Modification to the Maestro SystemBioHorizons Implant Systems, Inc. · 2002
- 5 generations backK022795 Modification to the Maestro SystemBioHorizons Implant Systems, Inc. · 2002
- 4 generations backK030463 Modification to the Maestro SystemBioHorizons Implant Systems, Inc. · 2003 · Recalled
- 3 generations backK032351 The Maestro System 3.0MM Diameter ImplantBioHorizons Implant Systems, Inc. · 2003
- 2 generations backK041938 Maximus OS (Overdenture System)BioHorizons Implant Systems, Inc. · 2004 · Recalled
- 1 generation backK063364 Alpha Bio Dental Implant SystemAlpha-Bio Tec, Ltd. · 2007
- This deviceK082800 Star/Vent Internal Hex Screw ImplantPark Dental Research Corp. · 2010
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −10 | K960026 | Biohorizons Dental Implant System | BioHorizons Implant Systems, Inc. | 1996 | — |
| −9 | K964330 | Biohorizons Dental Implant System (Name Subject to Change) | BioHorizons Implant Systems, Inc. | 1997 | — |
| −8 | K972313 | The Maestro System | BioHorizons Implant Systems, Inc. | 1997 | — |
| −7 | K020133 | Modification to the Maestro System | BioHorizons Implant Systems, Inc. | 2002 | — |
| −6 | K020645 | Modification to the Maestro System | BioHorizons Implant Systems, Inc. | 2002 | — |
| −5 | K022795 | Modification to the Maestro System | BioHorizons Implant Systems, Inc. | 2002 | — |
| −4 | K030463 | Modification to the Maestro System | BioHorizons Implant Systems, Inc. | 2003 | 1 |
| −3 | K032351 | The Maestro System 3.0MM Diameter Implant | BioHorizons Implant Systems, Inc. | 2003 | — |
| −2 | K041938 | Maximus OS (Overdenture System) | BioHorizons Implant Systems, Inc. | 2004 | 2 |
| −1 | K063364 | Alpha Bio Dental Implant System | Alpha-Bio Tec, Ltd. | 2007 | — |
| 0 (this device) | K082800 | Star/Vent Internal Hex Screw Implant | Park Dental Research Corp. | 2010 | — |
Other ancestors by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 1988 | 1 | 0 |
| 1989 | 1 | 0 |
| 1990 | 3 | 0 |
| 1993 | 2 | 0 |
| 1994 | 2 | 0 |
| 1995 | 3 | 0 |
| 1996 | 7 | 0 |
| 1997 | 3 | 0 |
| 1998 | 3 | 0 |
| 1999 | 7 | 0 |
| 2000 | 6 | 0 |
| 2001 | 10 | 0 |
| 2002 | 8 | 0 |
| 2003 | 7 | 0 |
| 2004 | 3 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in DZE? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new DZE device
- #1 K211090 ZENEX Implant Systemscore 25.4 · 15 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (5)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary; numbers the summary cites that cannot be its predicate are marked – and kept off the family tree.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K063364 | Alpha Bio Dental Implant SystemSummary page 1…Endosseous dental implant Classification Name: Endosseous dental implant 3. Substantial Equivalence: Alpha Bio (K063364) 3i Osseotite (K022009, K022113 Mis (… | 2007 |
| * | K022009 | 3I Implants; Osseotite Dental Implants; Osseotite NT Dental ImplantsSummary page 1…Endosseous dental implant 3. Substantial Equivalence: Alpha Bio (K063364) 3i Osseotite (K022009, K022113 Mis (K04007, K003191) 4. Description of the Device The Park Star/V… | 2002 |
| * | K022113 | 3I Dental Implant AccessoriesSummary page 1…Endosseous dental implant 3. Substantial Equivalence: Alpha Bio (K063364) 3i Osseotite (K022009, K022113 Mis (K04007, K003191) 4. Description of the Device The Park Star/Vent Inter… | 2002 |
| Kept off the family tree | K040007 | FDA’s K040007 is Interferential Stimulator, Model BMLS02-6 Not matched in our reading of the summary (scans can blur digits), so it is kept off the family tree | 2004 |
| * | K003191 | Mis Implant System DeciveSummary page 1…Alpha Bio (K063364) 3i Osseotite (K022009, K022113 Mis (K04007, K003191) 4. Description of the Device The Park Star/Vent Internal Hex Screw Implant is a root form endosseous dental implant… | 2001 |
What descends from it?
No later submission names this one as a predicate yet.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- The line of descent spans 14 years and passes through 3 companies; a new generation was cleared every 9 months on median.
- 7 of the 76 ancestors have a recall of any class.
- 12 other devices also cite its predicate K063364.
How does its category compare?
All DZE devicesDZE Implant, Endosseous, Root-Form: FDA decisions, review times, recalls and adverse event reports over 20 years. 2010, this device’s year, is highlighted.
FDA decisions per year · DZE
31in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · DZE
184in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · DZE
1in 2025
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · DZE
465,788in 2025
MAUDE reports naming product code DZE, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 43 | 107 | 11 | 225 |
| 2008 | 61 | 118 | 4 | 393 |
| 2009 | 41 | 110 | 3 | 164 |
| 2010 | 34 | 162 | 3 | 360 |
| 2011 | 26 | 194 | 0 | 362 |
| 2012 | 39 | 174 | 11 | 358 |
| 2013 | 42 | 195 | 1 | 391 |
| 2014 | 36 | 265 | 7 | 1,124 |
| 2015 | 36 | 215 | 3 | 2,894 |
| 2016 | 40 | 219 | 15 | 1,116 |
| 2017 | 48 | 223 | 4 | 9,719 |
| 2018 | 41 | 200 | 4 | 12,892 |
| 2019 | 31 | 231 | 8 | 167,016 |
| 2020 | 41 | 230 | 0 | 255,524 |
| 2021 | 34 | 182 | 6 | 479,618 |
| 2022 | 34 | 243 | 0 | 483,224 |
| 2023 | 35 | 248 | 0 | 537,585 |
| 2024 | 40 | 222 | 1 | 473,629 |
| 2025 | 31 | 184 | 1 | 465,788 |
| 2026 | 15 | 194 | 2 | — |
What is it indicated for?
The StarNent Internal Hex Screw Implant is intended for placement in the bone of the upper or lower jaw to support prosthetic devices such as artificial teeth, crowns, bridges or overdentures in edentulous or partially edentulous patients and to restore the patient's chewing function. It is intended for immediate loading when good primary stability has been achieved and with appropriate occlusal loading,
Indications for use as stated in the FDA summary.
https://510kreport.com/device/K082800 · printed Nov 6, 2026
Cite this page
510(k) Report. “K082800: Star/Vent Internal Hex Screw Implant.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K082800
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026