510(k) Report

510(k) · Cleared

Cleared

Equashield System

K083152510(k) TraditionalCleared Feb 2, 2009101-day reviewClass II21 CFR 880.5440

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Plastmed, Ltd. · LHI Set, I.V. Fluid Transfer

Cleared on Feb 2, 2009 as substantially equivalent to K972527 (Quality System Consulting, 1997) and 2 other predicates after a 101-day review. Its family tree reaches back 4 generations to 1988. 9 later devices descend from it.

Decided
Feb 2, 2009
Review
101 days
Class
Class II
Product code
LHI
Recalls
None
Predicates
3

Its longest line of descent runs back 4 generations to K883614 (1988). 11 ancestors in all. 9 later devices descend from it, 2 citing it directly.

Other ancestors, by year clearedDescendants, by year cleared 2007: 1 other ancestor2006: 1 other ancestor1995: 2 other ancestors1994: 1 other ancestor2005: 1 other ancestor1997: 1 other ancestor2010: 1 descendant cleared2009: 1 descendant cleared2014: 1 descendant cleared2017: 1 descendant cleared2022: 1 descendant cleared2023: 1 descendant cleared2024: 1 descendant cleared2025: 2 descendants clearedK883614 · Cytoguard (R) · Survival Technology, Inc. · 1988K972527 · Phaseal, System for Sealed Handling of Chemotherapeutic Agents · Quality System Consulting · 1997K980381 · Phaseal, Closed System Forhandling of Parenteral Drugs, Additional Administration Devices. C80 Infusion Adapter, A10 Pro · Carmel Pharma Ab. · 1998K051669 · Tevadaptor Closed Drug Reconstitution and Transfer System · Migada Plant · 2005 · recalled1990200020102020
Other ancestors, by generationDescendants, by generation 1 generation back: 1 other ancestor2 generations back: 4 other ancestors3 generations back: 1 other ancestor4 generations back: 1 other ancestor 1 generation forward: 2 descendants2 generations forward: 1 descendant3 generations forward: 1 descendant4 generations forward: 2 descendants5 generations forward: 1 descendant6 generations forward: 2 descendants K051669 · Tevadaptor Closed Drug Reconstitution and Transfer System · Migada Plant · 2005 · recalledK980381 · Phaseal, Closed System Forhandling of Parenteral Drugs, Additional Administration Devices. C80 Infusion Adapter, A10 Pro · Carmel Pharma Ab. · 1998K972527 · Phaseal, System for Sealed Handling of Chemotherapeutic Agents · Quality System Consulting · 1997K883614 · Cytoguard (R) · Survival Technology, Inc. · 19880+5
  1. Root · 4 generations backK883614 Cytoguard (R)Survival Technology, Inc. · 1988
  2. 3 generations backK972527 Phaseal, System for Sealed Handling of Chemotherapeutic AgentsQuality System Consulting · 1997
  3. 2 generations backK980381 Phaseal, Closed System Forhandling of Parenteral Drugs, Additional…Carmel Pharma Ab. · 1998
  4. 1 generation backK051669 Tevadaptor Closed Drug Reconstitution and Transfer SystemMigada Plant · 2005 · Recalled
  5. This deviceK083152 Equashield SystemPlastmed, Ltd. · 2009
  6. Descendant · cites it directly · 8 of its ownK091389 Equalshield Luer Lock Connector PairPlastmed, Ltd. · 2009
  7. Descendant · cites it directly · 7 of its ownK101940 Equashield System Protective PlusEquashield Medical, Ltd. · 2010
  8. Descendant · 2 generations on · 6 of its ownK132899 Equashield Closed System Drug Transfer Device (CSTD)Equashield Medical, Ltd. · 2014
  9. Descendant · 3 generations on · 5 of its ownK170706 Equashield Closed System drug Transfer Device (CSTD)Equashield Medical, Ltd. · 2017
  10. Descendant · 4 generations on · 3 of its ownK201460 Closed System Transfer DeviceShinva Ande Healthcare Apparatus Co., Ltd. · 2022

Showing 5 of 9 descendants. See all descendants

Descendants cleared per year

2009: 12010: 12014: 12017: 12022: 12023: 12024: 12025: 2
2009high 2 (2025) · low 0 (2011)2026

Most influential descendants

Showing 5 of 9 · See all
  • K091389Equalshield Luer Lock Connector PairPlastmed, Ltd. · 2009 · cites it directly8descendants
  • K101940Equashield System Protective PlusEquashield Medical, Ltd. · 2010 · cites it directly7descendants
  • K132899Equashield Closed System Drug Transfer Device (CSTD)Equashield Medical, Ltd. · 2014 · 2 generations on6descendants
  • K170706Equashield Closed System drug Transfer Device (CSTD)Equashield Medical, Ltd. · 2017 · 3 generations on5descendants
  • K201460Closed System Transfer DeviceShinva Ande Healthcare Apparatus Co., Ltd. · 2022 · 4 generations on3descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−4K883614Cytoguard (R)Survival Technology, Inc.1988—
−3K972527Phaseal, System for Sealed Handling of Chemotherapeutic AgentsQuality System Consulting1997—
−2K980381Phaseal, Closed System Forhandling of Parenteral Drugs, Additional…Carmel Pharma Ab.1998—
−1K051669Tevadaptor Closed Drug Reconstitution and Transfer SystemMigada Plant20051
0 (this device)K083152Equashield SystemPlastmed, Ltd.2009—
+1K091389Equalshield Luer Lock Connector PairPlastmed, Ltd.2009—
+1K101940Equashield System Protective PlusEquashield Medical, Ltd.2010—
+2K132899Equashield Closed System Drug Transfer Device (CSTD)Equashield Medical, Ltd.2014—
+3K170706Equashield Closed System drug Transfer Device (CSTD)Equashield Medical, Ltd.2017—
+4K201460Closed System Transfer DeviceShinva Ande Healthcare Apparatus Co., Ltd.2022—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199410
199520
199710
200510
200610
200710

Descendants by year cleared

Year clearedDevicesWith a Class I recall
200910
201010
201410
201710
202210
202310
202410
202520
FIG. 1 — Lineage of K083152, 1988–2025Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in LHI? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new LHI device

  1. #1 K252987 ADRx™ Admixture Devicescore 12.4 · 4 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (3)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K972527Phaseal, System for Sealed Handling of Chemotherapeutic Agents
Summary page 1
…s claimed: 1. PhaSeal closed system for the preparation and administration of parenteral drugs; Carmel Pharma. AB K972527 2. TEVADAPTOR; Mfigada Plant K05 1669 3. Texiufm~ Syringe; Cardinal Health, A…
Quality System Consulting1997—
*K051669Tevadaptor Closed Drug Reconstitution and Transfer System
Summary page 1
…for the preparation and administration of parenteral drugs; Carmel Pharma. AB K972527 2. TEVADAPTOR; Mfigada Plant K05 1669 3. Texiufm~ Syringe; Cardinal Health, Aleris® Prodticts K071 108…
Migada Plant20051
*K071108Texium Syringe
Summary page 1
…rmel Pharma. AB K972527 2. TEVADAPTOR; Mfigada Plant K05 1669 3. Texiufm~ Syringe; Cardinal Health, Aleris® Prodticts K071 108 2-2 Plastmed Ltd. IEQUASHIELD TM 510k Notification ===…
Cardinal Health, Alaris Products20071

Also cleared against K972527: 4 other devices →

What descends from it? (9)

2 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K091389Equalshield Luer Lock Connector PairPlastmed, Ltd.20098
K101940Equashield System Protective PlusEquashield Medical, Ltd.20107

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 21 years and passes through 5 companies; a new generation was cleared every 7.5 years on median.
  • 5 of the 11 ancestors have a recall of any class.
  • Of its descendants, K091389 (Plastmed, Ltd., 2009) has gone furthest, with 8 descendants of its own.
  • 4 other devices also cite its predicate K972527.

How does its category compare?

All LHI devices

LHI Set, I.V. Fluid Transfer: FDA decisions, review times, recalls and adverse event reports over 20 years. 2009, this device’s year, is highlighted.

FDA decisions per year · LHI

6in 2025

2007: 32008: 42009: 82010: 52011: 32012: 52013: 42014: 62015: 32016: 32017: 52018: 12019: 42020: 32021: 32022: 62023: 52024: 92025: 62026 (partial year): 2
2007high 9 (2024) · low 1 (2018)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · LHI

196in 2025

2007: 89 days median2008: 154 days median2009: 95 days median2010: 139 days median2011: 99 days median2012: 127 days median2013: 102 days median2014: 63 days median2015: 99 days median2016: 159 days median2017: 56 days median2019: 247 days median2020: 189 days median2021: 396 days median2022: 278 days median2023: 90 days median2024: 166 days median2025: 196 days median
2007high 396 (2021) · low 56 (2017)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · LHI

1in 2024

2007: 12008: 32009: 12010: 32011: 122013: 32016: 1, 1 Class I2017: 12018: 3, 3 Class I2019: 12022: 22023: 2, 2 Class I2024: 12026 (partial year): 1
2007high 12 (2011) · low 0 (2012)2026

Class I (6 since 2007) Class II/III not classified

Adverse event reports per year · LHI

1,334in 2025

2007: 182008: 272009: 372010: 492011: 1552012: 5292013: 1542014: 1552015: 1282016: 2192017: 5362018: 1,4992019: 1,6342020: 1,1712021: 9332022: 1,8342023: 1,0472024: 1,2702025: 1,334
2007high 1,834 (2022) · low 18 (2007)2025

MAUDE reports naming product code LHI, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
2007389118
20084154327
2009895137
20105139349
201139912155
201251270529
201341023154
20146630155
20153990128
201631591 (1)219
20175561536
20181—3 (3)1,499
2019424711,634
2020318901,171
202133960933
2022627821,834
20235902 (2)1,047
2024916611,270
2025619601,334
20262—1—

What is it indicated for?

The EQUASHIELD TM Drug Reconstitution and Transfer System is a contained system to be used by pharmacists or other healthcare professionals to prepare drugs, including cytotoxic drugs, for intravenous infusion or injection

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K083152: Equashield System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K083152

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026