510(k) Report

510(k) · Cleared

Recalled · Class II · 2024

Vitros Immunodiagnostic Products TSH Reagent Pack and Calibrators, Vitros 3600 Immunodiagnostic System

K083173510(k) SpecialCleared Dec 22, 200856-day reviewClass II21 CFR 862.1690Recalls 26

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Ortho-Clinical Diagnostics · JLW Radioimmunoassay, Thyroid-Stimulating Hormone

Cleared on Dec 22, 2008 as substantially equivalent to K081543 (Ortho-Clinical Diagnostics, Inc., 2008) after a 56-day review. Its family tree reaches back 2 generations to 1994. It has been recalled 26 times.

Decided
Dec 22, 2008
Review
56 days
Class
Class II
Product code
JLW
Recalls
26
Predicates
1

Its longest line of descent runs back 2 generations to K941142 (1994). 3 ancestors in all. No later device cites it as a predicate yet.

  1. Root · 2 generations backK941142 Kodak Ektachem Clinical Chemistry Slide PhenytoinEastman Kodak Company · 1994 · Recalled
  2. 1 generation backK081543 Vitros Immunodiagnostic Products TSH Reagent Pack and Calibrators…Ortho-Clinical Diagnostics, Inc. · 2008 · Recalled
  3. This deviceK083173 Vitros Immunodiagnostic Products TSH Reagent Pack and Calibrators…Ortho-Clinical Diagnostics · 2008
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−2K941142Kodak Ektachem Clinical Chemistry Slide PhenytoinEastman Kodak Company19945
−1K081543Vitros Immunodiagnostic Products TSH Reagent Pack and Calibrators, Vitros 5600…Ortho-Clinical Diagnostics, Inc.200839
0 (this device)K083173Vitros Immunodiagnostic Products TSH Reagent Pack and Calibrators, Vitros 3600…Ortho-Clinical Diagnostics2008—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199610
FIG. 1 — Lineage of K083173, 1994–2008Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in JLW? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new JLW device

  1. #1 K251543 Atellica® IM TSH3-Ultra II (TSH3ULII)score 11.4 · 3 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K081543Vitros Immunodiagnostic Products TSH Reagent Pack and Calibrators, Vitros 5600…
Summary page 1
…viously cleared for use with the VITROS ECi/ECiQ Immunodiagnostic System and VITROS 5600 Integrated System (K081543). The modifications include the use of the VITROS TSH Reagent Pack and Calibrators with the…
Ortho-Clinical Diagnostics, Inc.200839
†K962919Vitros Immunodiagnostic SystemJohnson & Johnson Clinical Diagnostics, Inc.19965

Also cleared against K081543: 1 other device →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

Recalls of this device

DateClassRecallRoot causeReason
Dec 19, 2024Class IIZ-1007-2025Software Design ChangeThe VITROS 3600 Immunodiagnostic System software versions 3.8.0 may not correctly notify users if the Signal Reagent Pack exceeds the on-board and/or shelf-life expiration date. This could result in the use of expired products, which…
Jan 26, 2024Class IIZ-1229-2024Software Design ChangeA software defect affecting VITROS Systems running VITROS Software Versions 3.8.0 and 3.8.1 causes the Configurable Westgard Rules to not report as expected. When a new control is defined, configurable Westgard rules, if selected, are not…
Jan 26, 2024Class IIZ-1224-2024Software Design ChangeA software defect affecting VITROS Systems running VITROS Software Versions 3.8.1 causes QC baseline statistics to not update as expected when changed by the user. This may cause erroneous patient results to be reported.
Jan 22, 2024Class IIZ-1220-2024Component change controlPotential For Aspiration from Unintended Sample Container During Sampling Center Processing on VITROS¿ 3600 Immunodiagnostic Systems and VITROS¿ 5600/XT 7600 Integrated Systems which may lead to erroneous test results.
Oct 10, 2023Class IIZ-0543-2024Under Investigation by firmDuring planned monitoring of data post-release of Software Version 3.8.0 an increased occurrence of software issues relating to unresponsive subsystems, unresponsive user interface (sometimes referred to as a screen freeze), and/or…
Aug 9, 2023Class IIZ-0008-2024Under Investigation by firmOrtho Clinical Diagnostics (QuidelOrtho) confirmed certain Proboscis/Piston Assemblies manufactured between 07-Apr-2022 (Date code: 040722) and 19-Dec-2022 (Date code: 121922) may not perform as intended due to an out-of-specification…
May 20, 2020Class IIZ-2481-2020Under Investigation by firmModifications to MicroWell Qualitative Assay Parameters Not Retained- may be inadvertently reset to default in certain circumstances
May 20, 2020Class IIZ-2480-2020Under Investigation by firmModifications to MicroWell Qualitative Assay Parameters Not Retained- may be inadvertently reset to default in certain circumstances
May 20, 2020Class IIZ-2482-2020Under Investigation by firmModifications to MicroWell Qualitative Assay Parameters Not Retained- may be inadvertently reset to default in certain circumstances
May 20, 2020Class IIZ-2484-2020Under Investigation by firmModifications to MicroWell Qualitative Assay Parameters Not Retained- may be inadvertently reset to default in certain circumstances
May 20, 2020Class IIZ-2483-2020Under Investigation by firmModifications to MicroWell Qualitative Assay Parameters Not Retained- may be inadvertently reset to default in certain circumstances
Feb 20, 2019Class IIZ-1290-2019Software designLuminometer Malfunction May Cause Inability to Process MicroWell Assays on VITROS¿ Systems
Feb 20, 2019Class IIZ-1289-2019Software designLuminometer Malfunction May Cause Inability to Process MicroWell Assays on VITROS¿ Systems
Oct 19, 2018Class IIZ-0652-2019Software Manufacturing/Software DeploymentSoftware anomaly may incorrectly extend the on-analyzer stability time for a loaded VITROS Reagent.
Jan 11, 2018Class IIIZ-1322-2018Nonconforming Material/ComponentVITROS TSH reagent lots have been found to generate higher than expected Calibrator level 2 signals on some customer systems. These Calibrator Level 2 responses cause a higher than expected frequency of customer generated calibration…
Jul 28, 2016Class IIIZ-2580-2016Under Investigation by firmA field correction was issued by the firm for VITROS TSH reagent lot 5040 due to a higher than expected frequency of customer calibration curves falling outside of the calibration quality parameters and therefore unusable to process…
Apr 6, 2016Class IIZ-1913-2016Software designOrtho Clinical Diagnostics confirmed a software timing anomaly in which the VITROS 3600 and 5600 Systems may unexpectedly aspirate from or dispense into an unintended sample that may lead to erroneous or contaminated results.
Nov 3, 2015Class IIZ-0640-2016Software designSoftware anomaly may allow VITROS Systems to sample and process assays while the fluids and reagent temperatures are not in the required temperature range for optimal processing. When this intermittent issue occurs, the VITROS Systems…
Nov 19, 2014Class IIZ-0967-2015Software designSoftware Anomaly: the firm has identified an anomaly with VITROS System Software Version 3.1 and below, and determined that the software may not properly identify an expired calibration.
Nov 19, 2014Class IIZ-0969-2015Software designSoftware Anomaly: the firm has identified an anomaly with VITROS System Software Version 3.1 and below, and determined that the software may not properly identify an expired calibration.
Nov 19, 2014Class IIZ-0968-2015Software designSoftware Anomaly: the firm has identified an anomaly with VITROS System Software Version 3.1 and below, and determined that the software may not properly identify an expired calibration.
Jul 7, 2014Class IIZ-2139-2014Software in the Use EnvironmentOrtho Clinical Diagnostics has identified an anomaly with VITROS System Software Version 3.0 and below. Internal testing confirmed that under very specific conditions, incorrect patient demographics were associated with a sample…
May 6, 2013Class IIZ-1650-2013Device DesignThere is evidence that an electrical short within the systems connector has caused an accumulation of heat which has radiated back through the wiring harness causing the wires and connectors to melt.
Mar 15, 2012Not classifiedZ-1468-2012Nonconforming Material/ComponentOrtho-Clinical Diagnostics is recalling VITROS Chemistry Systems due to possible internal hard drive failure.
Apr 13, 2011Not classifiedZ-1072-2012Software designOrtho Clinical Diagnostics (OCD) received customer complaints regarding the loss of calibration data following the installation of a development Assay Data Disk (ADD) that was available in the on-screen mailbox on the Main Menu System…
Apr 13, 2011Not classifiedZ-1073-2012Software designOrtho Clinical Diagnostics (OCD) received customer complaints regarding the loss of calibration data following the installation of a development Assay Data Disk (ADD) that was available in the on-screen mailbox on the Main Menu System…

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 14 years and passes through 3 companies; a new generation was cleared every 14.4 years on median.
  • 2 of the 3 ancestors have a recall of any class.
  • 1 other device also cites its predicate K081543.

How does its category compare?

All JLW devices

JLW Radioimmunoassay, Thyroid-Stimulating Hormone: FDA decisions, review times, recalls and adverse event reports over 20 years. 2008, this device’s year, is highlighted.

FDA decisions per year · JLW

1in 2025

2008: 52009: 22010: 12012: 12013: 12014: 12015: 32016: 32017: 42019: 12022: 12023: 12024: 22025: 12026 (partial year): 1
2007high 5 (2008) · low 0 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · JLW

194in 2017

2008: 143 days median2015: 142 days median2016: 238 days median2017: 194 days median
2007high 238 (2016) · low 142 (2015)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · JLW

2in 2025

2007: 12010: 12011: 12012: 32016: 12018: 42019: 12020: 22024: 22025: 2
2007high 4 (2018) · low 0 (2008)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · JLW

103in 2025

2007: 192008: 102009: 412010: 342011: 1672012: 1442013: 1682014: 1552015: 2032016: 1832017: 2352018: 2492019: 2162020: 1452021: 1462022: 1372023: 1622024: 1692025: 103
2007high 249 (2018) · low 10 (2008)2025

MAUDE reports naming product code JLW, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—119
20085143010
20092—041
20101—134
20110—1167
20121—3144
20131—0168
20141—0155
201531420203
201632381183
201741940235
20180—4249
20191—1216
20200—2145
20210—0146
20221—0137
20231—0162
20242—2169
20251—2103
20261—0—

What is it indicated for?

VITROS Immunodiagnostic Products TSH Reagent Pack For the in vitro quantitative measurement of thyroid stimulating hormone (TSH) in human serum and plasma (EDTA or Heparin) using the VITROS ECi/ECiQ Immunodiagnostic Systems, VITROS 3600 Immunodiagnostic System and VITROS 5600 Integrated System to aid in the differential diagnosis of thyroid disease. VITROS Immunodiagnostic Products TSH Calibrators For in vitro use in the calibration of the VITROS…

Read the full statement (121 words)

VITROS Immunodiagnostic Products TSH Reagent Pack

For the in vitro quantitative measurement of thyroid stimulating hormone (TSH) in human serum and plasma (EDTA or Heparin) using the VITROS ECi/ECiQ Immunodiagnostic Systems, VITROS 3600 Immunodiagnostic System and VITROS 5600 Integrated System to aid in the differential diagnosis of thyroid disease.

VITROS Immunodiagnostic Products TSH Calibrators

For in vitro use in the calibration of the VITROS ECi/ECiQ Immunodiagnostic Systems, VITROS 3600 Immunodiagnostic System and VITROS 5600 Integrated System for the quantitative measurement of thyroid stimulating hormone (TSH) in human serum and plasma (EDTA or Heparin).

VITROS 3600 Immunodiagnostic System

For use in the in vitro quantitative, semi-quantitative, and qualitative measurement of a variety of analytes of clinical interest, using VITROS Immunodiagnostic Products Reagents.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K083173: Vitros Immunodiagnostic Products TSH Reagent Pack and Calibrators, Vitros 3600 Immunodiagnostic System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K083173

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026