510(k) · Cleared
Recalled · Class II · 2018Microdot Xtra
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Cambridge Sensors Limited · NBW System, Test, Blood Glucose, Over The Counter
Cleared on Nov 19, 2009 as substantially equivalent to K070524 (Cambridge Sensors Limited, 2007) after a 378-day review. Its family tree reaches back 1 generation to 2007. 1 later device descends from it. It has been recalled once.
- Decided
- Nov 19, 2009
- Review
- 378 days
- Class
- Class II
- Product code
- NBW
- Recalls
- 1
- Predicates
- 1
Its longest line of descent runs back 1 generation to K070524 (2007). 1 later device descends from it, 1 citing it directly.
Most influential descendants
Showing 1 of 1 · See all- K102383Microdot & Microdot XtraCambridge Sensors Limited · 2012 · cites it directly0descendants
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −1 | K070524 | Microdot Blood Glucose Monitoring System | Cambridge Sensors Limited | 2007 | — |
| 0 (this device) | K083273 | Microdot Xtra | Cambridge Sensors Limited | 2009 | — |
| +1 | K102383 | Microdot & Microdot Xtra | Cambridge Sensors Limited | 2012 | — |
Descendants by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 2012 | 1 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in NBW? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new NBW device
- #1 K260545 CONTOUR® PLUS BLUE Blood Glucose Monitoring…score 14.6 · 10 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (1)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K070524 | Microdot Blood Glucose Monitoring SystemSummary page 3…asure current generated on disposable test strips. The strip remains unchanged since the last submission approval, microdot®Blood Glucose Monitoring System (k070524). The Test Strip manufacturing and performance characteristics are unchanged. The test strips are designed to quantitativ… | 2007 |
What descends from it? (1)
1 later device cites it directly; ranked here by how many devices descend from each in turn.
| Number | Device | Decided | Descendants |
|---|---|---|---|
| K102383 | Microdot & Microdot Xtra | 2012 | 0 |
Has anything in its family been recalled? (0 Class I)
Recalls of this device
| Date | Class | Recall | Root cause | Reason |
|---|---|---|---|---|
| Jul 26, 2018 | Class II | Z-2357-2019 | Nonconforming Material/Component | The firm reported that a faulty cutting/punching machine did not meet specifications after being fitted with new blades and did not correctly "notch" BG test strips intended for use in the US. The impacted strips did not fit into the… |
No ancestor or descendant has a Class I recall.
What does this lineage say?
How does its category compare?
All NBW devicesNBW System, Test, Blood Glucose, Over The Counter: FDA decisions, review times, recalls and adverse event reports over 20 years. 2009, this device’s year, is highlighted.
FDA decisions per year · NBW
2in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · NBW
243in 2024
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · NBW
1in 2025
Class I (2 since 2007) Class II/III not classified
Adverse event reports per year · NBW
4,745in 2025
MAUDE reports naming product code NBW, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 29 | 85 | 9 | 7,991 |
| 2008 | 37 | 128 | 2 | 7,704 |
| 2009 | 38 | 140 | 5 | 10,963 |
| 2010 | 31 | 132 | 11 | 11,631 |
| 2011 | 30 | 328 | 1 | 22,909 |
| 2012 | 30 | 230 | 1 | 23,449 |
| 2013 | 47 | 167 | 5 (2) | 35,408 |
| 2014 | 24 | 202 | 1 | 38,524 |
| 2015 | 32 | 237 | 0 | 62,111 |
| 2016 | 20 | 233 | 1 | 76,621 |
| 2017 | 25 | 244 | 0 | 37,538 |
| 2018 | 19 | 168 | 0 | 16,911 |
| 2019 | 10 | 127 | 14 | 14,472 |
| 2020 | 7 | 121 | 0 | 10,703 |
| 2021 | 7 | 465 | 0 | 9,198 |
| 2022 | 12 | 410 | 0 | 8,103 |
| 2023 | 5 | 193 | 0 | 7,256 |
| 2024 | 7 | 243 | 0 | 6,220 |
| 2025 | 2 | — | 1 | 4,745 |
| 2026 | 5 | 190 | 0 | — |
What is it indicated for?
The microdot Xtra ®Blood Glucose Monitoring System is intended for self test use outside the body (in vitro diagnostic use only). It should be used only for testing fresh capillary whole blood samples from a fingerstick for glucose (sugar). It is not intended for use on neonates or in the diagnosis of or screening for diabetes mellitus. The microdotXtra ® Blood Glucose Monitoring System is intended for self testing of glucose in capillary whole blood…
Read the full statement (213 words)
The microdot Xtra ®Blood Glucose Monitoring System is intended for self test use outside the body (in vitro diagnostic use only). It should be used only for testing fresh capillary whole blood samples from a fingerstick for glucose (sugar). It is not intended for use on neonates or in the diagnosis of or screening for diabetes mellitus.
The microdotXtra ® Blood Glucose Monitoring System is intended for self testing of glucose in capillary whole blood from a fingerstick by persons with diabetes or by health care professionals in home settings or healthcare facilities.
The microdot Xtra ® Blood Glucose Meter is intended for the quantitative measurement of glucose in fresh capillary whole blood from a fingerstick. It is intended for use by persons with diabetes or by health care professionals in home settings or healthcare facilities.
The microdot Xtra ® Test Strips are intended for the quantitative measurement of glucose in fresh capillary whole blood from a fingerstick. It is intended for use by persons with diabetes or by health care professionals in home settings or healthcare facilities.
The microdot®Control solutions are intended for use with microdot Xtra ® Blood Glucose Meter and microdot Xtra ® Test Strips as a quality control check to verify the accuracy of the blood glucose test results.
Indications for use as stated in the FDA summary.
https://510kreport.com/device/K083273 · printed Nov 6, 2026
Cite this page
510(k) Report. “K083273: Microdot Xtra.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K083273
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026