510(k) Report

510(k) · Cleared

Cleared

Biopro K-Wire, Models 16863, 17231, 17232, 18577, 18682-18685

K083490510(k) TraditionalCleared Mar 18, 2009113-day reviewClass II21 CFR 888.3040

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Biopro, Inc. · HTY Pin, Fixation, Smooth

Cleared on Mar 18, 2009 after a 113-day review. The FDA summary names no predicate by number. 10 later devices descend from it.

Decided
Mar 18, 2009
Review
113 days
Class
Class II
Product code
HTY
Recalls
None
Predicates
0

10 later devices descend from it, 2 citing it directly.

Descendants, by year cleared 2023: 2 descendants cleared2011: 1 descendant cleared2015: 2 descendants cleared2017: 1 descendant cleared2016: 1 descendant cleared2022: 2 descendants cleared2026: 1 descendant cleared20052010201520202025
  1. This deviceK083490 Biopro K-Wire, Models 16863, 17231, 17232, 18577, 18682-18685Biopro, Inc. · 2009
  2. Descendant · cites it directly · 8 of its ownK110895 Ortho Solutions Trauma Implants for OsteosynthesisOrtho Solutions Limited · 2011
  3. Descendant · 2 generations on · 3 of its ownK163489 OrthoSolutions 'System26' Bone ScrewsOrtho Solutions UK Limited · 2017 · Recalled
  4. Descendant · 2 generations on · 2 of its ownK150889 Suture Wires and Wire LoopsZimmer, Inc. · 2015
  5. Descendant · 3 generations on · 1 of its ownK203773 BRM TOOL ScrewsBrm Extremities Srl · 2022
  6. Descendant · 3 generations on · 1 of its ownK151848 Cable-Ready® Cable Grip System: Cable-Ready Pin System, Cable-Ready…Zimmer, Inc. · 2016

Showing 5 of 10 descendants. See all descendants

Descendants cleared per year

2011: 12015: 22016: 12017: 12022: 22023: 22026: 1
2011high 2 (2015) · low 0 (2012)2026

Most influential descendants

Showing 5 of 10 · See all
  • K110895Ortho Solutions Trauma Implants for OsteosynthesisOrtho Solutions Limited · 2011 · cites it directly8descendants
  • K163489OrthoSolutions 'System26' Bone ScrewsOrtho Solutions UK Limited · 2017 · 2 generations on3descendants
  • K150889Suture Wires and Wire LoopsZimmer, Inc. · 2015 · 2 generations on2descendants
  • K203773BRM TOOL ScrewsBrm Extremities Srl · 2022 · 3 generations on1descendant
  • K151848Cable-Ready® Cable Grip System: Cable-Ready Pin System, Cable-Ready Needle SystemZimmer, Inc. · 2016 · 3 generations on1descendant
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
0 (this device)K083490Biopro K-Wire, Models 16863, 17231, 17232, 18577, 18682-18685Biopro, Inc.2009—
+1K110895Ortho Solutions Trauma Implants for OsteosynthesisOrtho Solutions Limited2011—
+2K163489OrthoSolutions 'System26' Bone ScrewsOrtho Solutions UK Limited20171
+2K150889Suture Wires and Wire LoopsZimmer, Inc.2015—
+3K203773BRM TOOL ScrewsBrm Extremities Srl2022—
+3K151848Cable-Ready® Cable Grip System: Cable-Ready Pin System, Cable-Ready Needle…Zimmer, Inc.2016—

Descendants by year cleared

Year clearedDevicesWith a Class I recall
201110
201520
201610
201710
202220
202320
202610
FIG. 1 — Lineage of K083490, 2009–2026Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in HTY? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new HTY device

  1. #1 K231272 OSSIOfiber® Pin Product Family, OSSIOfiber®…score 19.3 · 14 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against?

The FDA summary names no predicate by number.

What descends from it? (10)

2 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K110895Ortho Solutions Trauma Implants for OsteosynthesisOrtho Solutions Limited20118
K231339Tyber Medical Pin and Wire System (various)Tyber Medical, LLC20230

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • Of its descendants, K110895 (Ortho Solutions Limited, 2011) has gone furthest, with 8 descendants of its own.

How does its category compare?

All HTY devices

HTY Pin, Fixation, Smooth: FDA decisions, review times, recalls and adverse event reports over 20 years. 2009, this device’s year, is highlighted.

FDA decisions per year · HTY

5in 2025

2007: 62008: 62009: 22010: 92011: 62012: 42013: 42014: 82015: 82016: 62017: 52018: 42019: 42020: 52021: 52022: 42023: 52024: 12025: 52026 (partial year): 2
2007high 9 (2010) · low 1 (2024)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · HTY

90in 2025

2007: 112 days median2008: 86 days median2010: 180 days median2011: 82 days median2012: 76 days median2013: 128 days median2014: 73 days median2015: 101 days median2016: 114 days median2017: 127 days median2018: 162 days median2019: 93 days median2020: 108 days median2021: 137 days median2022: 121 days median2023: 146 days median2025: 90 days median
2007high 180 (2010) · low 73 (2014)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · HTY

2in 2022

2009: 12010: 12016: 22019: 12022: 22026 (partial year): 1
2007high 2 (2016) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · HTY

39in 2025

2007: 462008: 382009: 362010: 332011: 1642012: 1292013: 1872014: 1492015: 1212016: 1282017: 822018: 1382019: 2222020: 2102021: 1482022: 962023: 1532024: 2972025: 39
2007high 297 (2024) · low 33 (2010)2025

MAUDE reports naming product code HTY, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20076112046
2008686038
20092—136
20109180133
20116820164
20124760129
201341280187
20148730149
201581010121
201661142128
20175127082
201841620138
20194931222
202051080210
202151370148
20224121296
202351460153
20241—0297
2025590039
20262—1—

What is it indicated for?

The BioPro K-Wire is indicated for use in fixation of bone fractures, for bone reconstructions, and as guide pins for insertion of other implants or implantation through the skin so that traction may be applied to the skeletal system.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K083490: Biopro K-Wire, Models 16863, 17231, 17232, 18577, 18682-18685.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K083490

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026