510(k) Report

510(k) · Cleared

Recalled · Class II · 2023

Fresenius Sterile Stay Safe Cap

K083542510(k) TraditionalCleared Dec 29, 200831-day reviewClass II21 CFR 876.5630Recalls 2

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Fresenius Medical Care North America · KDJ Set, Administration, For Peritoneal Dialysis, Disposable

Cleared on Dec 29, 2008 as substantially equivalent to K921818 (Abbott Laboratories, 1994) after a 31-day review. Its family tree reaches back 1 generation to 1994. It has been recalled 2 times.

Decided
Dec 29, 2008
Review
31 days
Class
Class II
Product code
KDJ
Recalls
2
Predicates
1

Its longest line of descent runs back 1 generation to K921818 (1994). No later device cites it as a predicate yet.

K921818 · Abbott Smart Cap · Abbott Laboratories · 199419901995200020052010
K921818 · Abbott Smart Cap · Abbott Laboratories · 19940
  1. Root · 1 generation backK921818 Abbott Smart CapAbbott Laboratories · 1994
  2. This deviceK083542 Fresenius Sterile Stay Safe CapFresenius Medical Care North America · 2008
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−1K921818Abbott Smart CapAbbott Laboratories1994—
0 (this device)K083542Fresenius Sterile Stay Safe CapFresenius Medical Care North America2008—
FIG. 1 — Lineage of K083542, 1994–2008Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in KDJ? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new KDJ device

  1. #1 K250404 stay•safe® catheter extension set with Safe-…score 9.4 · 2 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K921818Abbott Smart Cap
Summary page 2
…rile Stay Safe® Cap is a modified version of the Fresenius Stay Safe Cap was cleared under the following premarket notifications: Fresenius Stay Safe®Cap · #K921818 (3/28/94); D. Indications for Usellntended Use: The Indications for Use/Intended Use for the Fresenius Sterile Stay Safe® Cap…
Abbott Laboratories1994—

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

Recalls of this device

DateClassRecallRoot causeReason
Oct 10, 2023Class IIZ-0507-2024Labeling designUpdating the labeling to include additional warnings and contraindications for potential side effects.
Apr 28, 2021Class IIZ-2090-2021Environmental controlExposed to freezing temperatures due to refrigerated truck malfunctions

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • Its one ancestor has no recall.

How does its category compare?

All KDJ devices

KDJ Set, Administration, For Peritoneal Dialysis, Disposable: FDA decisions, review times, recalls and adverse event reports over 20 years. 2008, this device’s year, is highlighted.

FDA decisions per year · KDJ

1in 2025

2008: 12013: 12015: 22016: 12018: 32019: 12022: 12024: 12025: 1
2007high 3 (2018) · low 0 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · KDJ

90in 2018

2018: 90 days median
2007high 90 (2018)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · KDJ

21in 2024

2009: 22013: 12015: 12020: 12022: 122023: 12024: 21, 10 Class I
2007high 21 (2024) · low 0 (2007)2026

Class I (10 since 2007) Class II/III not classified

Adverse event reports per year · KDJ

2,460in 2025

2007: 2192008: 4112009: 2332010: 1,8792011: 4,3152012: 4,2942013: 5,6232014: 7,6802015: 6,8702016: 7,0452017: 4,6362018: 3,3792019: 2,4562020: 2,8702021: 3,1672022: 2,9272023: 2,9472024: 3,1132025: 2,460
2007high 7,680 (2014) · low 219 (2007)2025

MAUDE reports naming product code KDJ, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—0219
20081—0411
20090—2233
20100—01,879
20110—04,315
20120—04,294
20131—15,623
20140—07,680
20152—16,870
20161—07,045
20170—04,636
201839003,379
20191—02,456
20200—12,870
20210—03,167
20221—122,927
20230—12,947
20241—21 (10)3,113
20251—02,460
20260—0—

What is it indicated for?

The Fresenius Sterile Stay Safe® Cap is intended to be used for closure of the stay safe peritoneal dialysis connectology system.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K083542: Fresenius Sterile Stay Safe Cap.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K083542

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026