510(k) Report

510(k) · Cleared

Cleared

Apieron Insight Eno System

K083617510(k) SpecialCleared Jan 27, 200950-day reviewClass II21 CFR 862.3080

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Apieron, Inc. · MXA System, Test, Breath Nitric Oxide

Cleared on Jan 27, 2009 as substantially equivalent to K073265 (Apieron, Inc., 2008) after a 50-day review. Its family tree reaches back 1 generation to 2008.

Decided
Jan 27, 2009
Review
50 days
Class
Class II
Product code
MXA
Recalls
None
Predicates
1

Its longest line of descent runs back 1 generation to K073265 (2008). No later device cites it as a predicate yet.

  1. Root · 1 generation backK073265 Apieron Insight Exhaled Nitric Oxide (Eno) SystemApieron, Inc. · 2008
  2. This deviceK083617 Apieron Insight Eno SystemApieron, Inc. · 2009
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−1K073265Apieron Insight Exhaled Nitric Oxide (Eno) SystemApieron, Inc.2008—
0 (this device)K083617Apieron Insight Eno SystemApieron, Inc.2009—
FIG. 1 — Lineage of K083617, 2008–2009Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in MXA? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new MXA device

  1. #1 K251674 Fenom Flo™ FeNO Monitoring Systemscore 11.3 · 4 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K073265Apieron Insight Exhaled Nitric Oxide (Eno) System
Summary page 1
…Class II Product Code: MXA Trade Name: Apieron INSIGHT'" eNO System Generic/Common Name: Breath Nitric Oxide Test System PREDICATE DEVICE Apieron INSIGHTT eNO System (K073265) M INTENDED USE The intended use of the Apieron INSIGHTT eNO System is to quantitatively measure…
Apieron, Inc.2008—

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • Its one ancestor has no recall.

How does its category compare?

All MXA devices

MXA System, Test, Breath Nitric Oxide: FDA decisions, review times, recalls and adverse event reports over 20 years. 2009, this device’s year, is highlighted.

FDA decisions per year · MXA

2in 2025

2008: 22009: 12010: 12012: 12014: 12015: 12017: 12019: 12021: 12023: 12024: 12025: 2
2007high 2 (2008) · low 0 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · MXA

Too few MXA 510(k)s in any year since 2007 to give a median.

Recalls per year · MXA

No recall names MXA since 2007.

Adverse event reports per year · MXA

No MAUDE report names MXA since 2007.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—00
20082—00
20091—00
20101—00
20110—00
20121—00
20130—00
20141—00
20151—00
20160—00
20171—00
20180—00
20191—00
20200—00
20211—00
20220—00
20231—00
20241—00
20252—00
20260—0—

What is it indicated for?

The intended use of the Apieron INSIGHT eNO System is to quantitatively measure exhaled nitric oxide (eNO) in expired human breath as a marker of inflammation in persons with asthma. Measurement of eNO in expired human breath by the Apieron INSIGHT eNO System is a non-invasive, simple and safe method to measure a decrease in eNO in asthma patients that often occurs after treatment with anti-inflammatory pharmacological therapy as an indication of the…

Read the full statement (164 words)

The intended use of the Apieron INSIGHT eNO System is to quantitatively measure exhaled nitric oxide (eNO) in expired human breath as a marker of inflammation in persons with asthma. Measurement of eNO in expired human breath by the Apieron INSIGHT eNO System is a non-invasive, simple and safe method to measure a decrease in eNO in asthma patients that often occurs after treatment with anti-inflammatory pharmacological therapy as an indication of the therapeutic effects in patients with elevated eNO levels. The Apieron INSIGHT eNO System is suitable for use in children ages 8 to 17 years of age, and in adults 18 years of age and older. eNO measurements, as an adjunct to established clinical assessments, provide the physician an objective marker to evaluate the patient's response to anti-inflammatory therapy. The Apieron INSIGHT eNO System can be used by trained operators in a physician's-office laboratory setting. The Apieron INSIGHT eNO System should not be used in critical care, emergency care or in anesthesiology.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K083617: Apieron Insight Eno System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 5, 2026. https://510kreport.com/device/K083617

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026