510(k) Report

510(k) · Cleared

Cleared

P.D Software

K083672510(k) TraditionalCleared Apr 13, 2009123-day reviewClass II21 CFR 892.5050

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

.Decimal, Inc. · MUJ System, Planning, Radiation Therapy Treatment

Cleared on Apr 13, 2009 as substantially equivalent to K061440 (.Decimal, Inc., 2006) after a 123-day review. Its family tree reaches back 3 generations to 1997. 7 later devices descend from it.

Decided
Apr 13, 2009
Review
123 days
Class
Class II
Product code
MUJ
Recalls
None
Predicates
1

Its longest line of descent runs back 3 generations to K971367 (1997). 4 ancestors in all. 7 later devices descend from it, 1 citing it directly.

Other ancestors, by year clearedDescendants, by year cleared 2000: 1 other ancestor2015: 1 descendant cleared2019: 1 descendant cleared2018: 1 descendant cleared2022: 1 descendant cleared2024: 2 descendants cleared2026: 1 descendant clearedK971367 · Brainscan Conformal RT Module · Brainlab AG · 1997K032762 · Xio Radiation Treatment Planning System · Computerized Medical Systems, Inc. · 2003K061440 · P.D · .Decimal, Inc. · 20061995200020052010201520202025
Other ancestors, by generationDescendants, by generation 3 generations back: 1 other ancestor 1 generation forward: 1 descendant2 generations forward: 2 descendants3 generations forward: 1 descendant4 generations forward: 2 descendants5 generations forward: 1 descendant K061440 · P.D · .Decimal, Inc. · 2006K032762 · Xio Radiation Treatment Planning System · Computerized Medical Systems, Inc. · 2003K971367 · Brainscan Conformal RT Module · Brainlab AG · 19970+5
  1. Root · 3 generations backK971367 Brainscan Conformal RT ModuleBrainlab AG · 1997
  2. 2 generations backK032762 Xio Radiation Treatment Planning SystemComputerized Medical Systems, Inc. · 2003
  3. 1 generation backK061440 P.D.Decimal, Inc. · 2006
  4. This deviceK083672 P.D Software.Decimal, Inc. · 2009
  5. Descendant · cites it directly · 6 of its ownK151369 .decimal p.d.Decimal, LLC · 2015
  6. Descendant · 2 generations on · 4 of its ownK180289 3D Bolus Software3D Bolus, Inc. · 2018
  7. Descendant · 3 generations on · 3 of its ownK213438 3D Bolus Software Application, 3D Brachy Software Application…Adaptiiv · 2022
  8. Descendant · 4 generations on · 1 of its ownK243057 TrueFit Bolus; TrueFlex BolusAdaptiiv Medical Technologies, Inc. · 2024
  9. Descendant · 5 generations on · 0 of its ownK260308 TrueFit BolusAdaptiiv Medical Technologies, Inc. · 2026

Showing 5 of 7 descendants. See all descendants

Descendants cleared per year

2015: 12018: 12019: 12022: 12024: 22026: 1
2015high 2 (2024) · low 0 (2016)2026

Most influential descendants

Showing 5 of 7 · See all
  • K151369.decimal p.d.Decimal, LLC · 2015 · cites it directly6descendants
  • K1802893D Bolus Software3D Bolus, Inc. · 2018 · 2 generations on4descendants
  • K2134383D Bolus Software Application, 3D Brachy Software Application, Patient-Matched 3D…Adaptiiv · 2022 · 3 generations on3descendants
  • K243057TrueFit Bolus; TrueFlex BolusAdaptiiv Medical Technologies, Inc. · 2024 · 4 generations on1descendant
  • K260308TrueFit BolusAdaptiiv Medical Technologies, Inc. · 2026 · 5 generations on0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−3K971367Brainscan Conformal RT ModuleBrainlab AG1997—
−2K032762Xio Radiation Treatment Planning SystemComputerized Medical Systems, Inc.2003—
−1K061440P.D.Decimal, Inc.2006—
0 (this device)K083672P.D Software.Decimal, Inc.2009—
+1K151369.decimal p.d.Decimal, LLC2015—
+2K1802893D Bolus Software3D Bolus, Inc.2018—
+3K2134383D Bolus Software Application, 3D Brachy Software Application, Patient-Matched…Adaptiiv2022—
+4K243057TrueFit Bolus; TrueFlex BolusAdaptiiv Medical Technologies, Inc.2024—
+5K260308TrueFit BolusAdaptiiv Medical Technologies, Inc.2026—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
200010

Descendants by year cleared

Year clearedDevicesWith a Class I recall
201510
201810
201910
202210
202420
202610
FIG. 1 — Lineage of K083672, 1997–2026Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in MUJ? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new MUJ device

  1. #1 K232799 syngo.via RT Image Suitescore 18.6 · 19 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K061440P.D
Summary page 1
…lassificationName: 90 MUJ J 21 CFR892.5050 Class II Predicate Device(s): *4decimal Inc. p.d (K061440) .decimal' The benchmark for custom radiation therapy Intended Use: The p.d…
.Decimal, Inc.2006—

What descends from it? (7)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K151369.decimal p.d.Decimal, LLC20156

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 12 years and passes through 3 companies; a new generation was cleared every 2.8 years on median.
  • 1 of the 4 ancestors has a recall of any class.
  • Of its descendants, K151369 (.Decimal, LLC, 2015) has gone furthest, with 6 descendants of its own.

How does its category compare?

All MUJ devices

MUJ System, Planning, Radiation Therapy Treatment: FDA decisions, review times, recalls and adverse event reports over 20 years. 2009, this device’s year, is highlighted.

FDA decisions per year · MUJ

10in 2025

2007: 42008: 92009: 162010: 112011: 92012: 82013: 52014: 92015: 132016: 52017: 72018: 72019: 92020: 92021: 112022: 82023: 102024: 92025: 102026 (partial year): 9
2007high 16 (2009) · low 4 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · MUJ

186in 2025

2007: 67 days median2008: 63 days median2009: 84 days median2010: 56 days median2011: 103 days median2012: 59 days median2013: 64 days median2014: 108 days median2015: 78 days median2016: 80 days median2017: 30 days median2018: 53 days median2019: 56 days median2020: 104 days median2021: 87 days median2022: 168 days median2023: 140 days median2024: 122 days median2025: 186 days median2026 (partial year): 233 days median
2007high 233 (2026) · low 30 (2017)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · MUJ

2in 2023

2007: 42008: 102009: 112010: 232011: 172012: 42013: 62014: 22015: 72016: 132017: 42018: 32019: 42020: 22021: 42022: 32023: 22026 (partial year): 2
2007high 23 (2010) · low 0 (2024)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · MUJ

21in 2025

2007: 242008: 512009: 242010: 782011: 732012: 392013: 332014: 352015: 302016: 272017: 162018: 252019: 252020: 262021: 152022: 222023: 762024: 92025: 21
2007high 78 (2010) · low 9 (2024)2025

MAUDE reports naming product code MUJ, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
2007467424
20089631051
200916841124
201011562378
201191031773
2012859439
2013564633
20149108235
20151378730
20165801327
2017730416
2018753325
2019956425
20209104226
20211187415
20228168322
202310140276
2024912209
202510186021
202692332—

What is it indicated for?

The p.d software is used by radiation therapy professionals to assist in the treatment of cancer patients. The p.d software takes a Treatment Planning System design of a compensating filter which contains steep, narrow, and unmachinable areas and then smoothes them out into a machinable surface. And the software converts Treatment Planning System compensator filter file into a .decimal file format. Optionally the user may elect to design a beam shaping…

Read the full statement (126 words)

The p.d software is used by radiation therapy professionals to assist in the treatment of cancer patients. The p.d software takes a Treatment Planning System design of a compensating filter which contains steep, narrow, and unmachinable areas and then smoothes them out into a machinable surface. And the software converts Treatment Planning System compensator filter file into a .decimal file format.

Optionally the user may elect to design a beam shaping compensator filter based on Treatment Planning System's data which will be transferred back into the Treatment Planning System for final dose verification. The customer uses the software in-house before sending the file to .decimal to be manufactured. Each filter must be QA'd and approved by a radiation therapy professional prior to use on a patient.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K083672: P.D Software.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K083672

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026