510(k) Report

510(k) · Cleared

Recalled · Class III · 2013

Vitros Chemistry Products K+DT Slides: Vitros Chemistry Products DT Calibrator Kit, Model K+DT Slides: 153 2258

K083680510(k) SpecialCleared Feb 27, 200977-day reviewClass II21 CFR 862.1600Recalls 1

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Ortho-Clinical Diagnostics, Inc. · CEM Electrode, Ion Specific, Potassium

Cleared on Feb 27, 2009 as substantially equivalent to K912844 (Eastman Kodak Company, 1991) and 1 other predicate after a 77-day review. Its family tree reaches back 4 generations to 1988. 2 later devices descend from it. It has been recalled once.

Decided
Feb 27, 2009
Review
77 days
Class
Class II
Product code
CEM
Recalls
1
Predicates
2

Its longest line of descent runs back 4 generations to K875191 (1988). 6 ancestors in all, the oldest K870035 (1987). 2 later devices descend from it, 1 citing it directly.

Other ancestors, by year clearedDescendants, by year cleared 1991: 1 other ancestor1987: 1 other ancestor2009: 1 descendant cleared2010: 1 descendant clearedK875191 · Kodak Ektachem DT Slides (CRSC) · Eastman Kodak Company · 1988×2: 2 generations cleared close together, K071216 (2007), K072443 (2007) K082099 · Vitros Chemistry Products CI-DT Slides; Vitros Chemistry Products DT Calibrator Kit, Models CI-DT Slides:131 4905 · Ortho-Clinical Diagnostics, Inc. · 20081990200020102020
  1. Root · 4 generations backK875191 Kodak Ektachem DT Slides (CRSC)Eastman Kodak Company · 1988
  2. 3 generations backK071216 Vitros Chemistry Products CRSC Slides, Vitros Chemistry Products DT…Ortho-Clinical Diagnostics, Inc. · 2007 · Recalled
  3. 2 generations backK072443 Vitros Chemistry Products CA DT Slides and DT Calibrator Kit and…Ortho-Clinical Diagnostics, Inc. · 2007 · Recalled
  4. 1 generation backK082099 Vitros Chemistry Products CI-DT Slides; Vitros Chemistry Products DT…Ortho-Clinical Diagnostics, Inc. · 2008
  5. This deviceK083680 Vitros Chemistry Products K+DT Slides: Vitros Chemistry Products DT…Ortho-Clinical Diagnostics, Inc. · 2009
  6. Descendant · cites it directly · 1 of its ownK091861 Vitros Chemistry Products NA + DT Slides, Model 153 2290 and DT…Ortho-Clinical Diagnostics, Inc. · 2009
  7. Descendant · 2 generations on · 0 of its ownK093611 Vitros Chemistry Products CO2 DT Slides; Vitros Chemmistry Products…Ortho-Clinical Diagnostics, Inc. · 2010

Most influential descendants

Showing 2 of 2 · See all
  • K091861Vitros Chemistry Products NA + DT Slides, Model 153 2290 and DT Calibrator Kit, Model…Ortho-Clinical Diagnostics, Inc. · 2009 · cites it directly1descendant
  • K093611Vitros Chemistry Products CO2 DT Slides; Vitros Chemmistry Products DT Calibrator Kit…Ortho-Clinical Diagnostics, Inc. · 2010 · 2 generations on0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−4K875191Kodak Ektachem DT Slides (CRSC)Eastman Kodak Company1988—
−3K071216Vitros Chemistry Products CRSC Slides, Vitros Chemistry Products DT Calibrator…Ortho-Clinical Diagnostics, Inc.20071
−2K072443Vitros Chemistry Products CA DT Slides and DT Calibrator Kit and Vitros CA AssayOrtho-Clinical Diagnostics, Inc.20071
−1K082099Vitros Chemistry Products CI-DT Slides; Vitros Chemistry Products DT…Ortho-Clinical Diagnostics, Inc.2008—
0 (this device)K083680Vitros Chemistry Products K+DT Slides: Vitros Chemistry Products DT Calibrator…Ortho-Clinical Diagnostics, Inc.2009—
+1K091861Vitros Chemistry Products NA + DT Slides, Model 153 2290 and DT Calibrator…Ortho-Clinical Diagnostics, Inc.2009—
+2K093611Vitros Chemistry Products CO2 DT Slides; Vitros Chemmistry Products DT…Ortho-Clinical Diagnostics, Inc.2010—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
198710
199110

Descendants by year cleared

Year clearedDevicesWith a Class I recall
200910
201010
FIG. 1 — Lineage of K083680, 1988–2010Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in CEM? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new CEM device

  1. #1 K253491 ISE indirect K for Gen.2; ISE indirect Na for…score 11.4 · 3 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (2)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K912844Kodak Ektachem Dtii System
Summary page 4
…ducts DT Calibrator Kit, which were Cleared by the FDA for in vitro diagnostic use. VITROS Chemistry Products K+DT Slide: (K912844, cleared September 4, 1991) VITROS Chemistry Products DT Calibrator Kit:(K082099, cleared August 21, 2008)…
Eastman Kodak Company1991—
*K082099Vitros Chemistry Products CI-DT Slides; Vitros Chemistry Products DT Calibrator Kit…
Summary page 4
…e. VITROS Chemistry Products K+DT Slide: (K912844, cleared September 4, 1991) VITROS Chemistry Products DT Calibrator Kit:(K082099, cleared August 21, 2008). Table 1 lists the characteristics of the tests performed using the VITROS K+ S…
Ortho-Clinical Diagnostics, Inc.2008—

Also cleared against K912844: 28 other devices →

What descends from it? (2)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K091861Vitros Chemistry Products NA + DT Slides, Model 153 2290 and DT Calibrator Kit, Model…Ortho-Clinical Diagnostics, Inc.20091

Has anything in its family been recalled? (0 Class I)

Recalls of this device

DateClassRecallRoot causeReason
May 9, 2013Class IIIZ-1614-2013Employee errorWhile performing interval testing, Ortho Clinical Diagnostics (OCD) determined that a surfactant was unintentionally added to VITROS Chemistry Products K+ Slides during the manufacturing process.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 21 years and passes through 2 companies; a new generation was cleared every 11 months on median.
  • 2 of the 6 ancestors have a recall of any class.
  • Of its descendants, K091861 (Ortho-Clinical Diagnostics, Inc., 2009) has gone furthest, with 1 descendant of its own.
  • 28 other devices also cite its predicate K912844.

How does its category compare?

All CEM devices

CEM Electrode, Ion Specific, Potassium: FDA decisions, review times, recalls and adverse event reports over 20 years. 2009, this device’s year, is highlighted.

FDA decisions per year · CEM

1in 2025

2007: 12009: 12010: 32011: 32012: 42020: 12023: 22025: 12026 (partial year): 1
2007high 4 (2012) · low 0 (2008)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · CEM

180in 2012

2010: 195 days median2011: 74 days median2012: 180 days median
2007high 195 (2010) · low 74 (2011)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · CEM

4in 2025

2008: 12010: 122011: 62016: 12019: 12020: 32021: 12023: 22025: 4
2007high 12 (2010) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · CEM

29in 2025

2007: 662008: 2452009: 792010: 1132011: 1262012: 452013: 372014: 42015: 72016: 62017: 322018: 132019: 252020: 272021: 182022: 162023: 302024: 422025: 29
2007high 245 (2008) · low 4 (2014)2025

MAUDE reports naming product code CEM, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20071—066
20080—1245
20091—079
2010319512113
20113746126
20124180045
20130—037
20140—04
20150—07
20160—16
20170—032
20180—013
20190—125
20201—327
20210—118
20220—016
20232—230
20240—042
20251—429
20261—0—

What is it indicated for?

VITROS Chemistry Products K + DT Slides quantitatively measure potassium (K +) concentration in serum and plasma using VITROS.DT60 and DT60 II Chemistry Systems. Potassium measurements are used to monitor electrolyte balance in the diagnosis and treatment of diseases or conditions characterized by low or high blood potassium levels. For in vitro diagnostic use only. VITROS Chemistry Products DT Calibrator Kit is specially formulated for use as…

Read the full statement (116 words)

VITROS Chemistry Products K + DT Slides quantitatively measure potassium (K +) concentration in serum and plasma using VITROS.DT60 and DT60 II Chemistry Systems. Potassium measurements are used to monitor electrolyte balance in the diagnosis and treatment of diseases or conditions characterized by low or high blood potassium levels. For in vitro diagnostic use only.

VITROS Chemistry Products DT Calibrator Kit is specially formulated for use as calibrators for the quantitative measurement of ALB, ALKP, ALT, AMYL, AST, TBIL, NBIL, BUN/UREA, Ca, CHOL, CK, Cl-, Co2, CREA, CRSC, Fe, GGT, GLU, HDLC, K+, LAC, LDH, LIPA, Mg, Na+, NI-3, PHOS, TP, TRIG, urCR, and URIC on VITROS DT Chemistry Systems. For in vitro diagnostic use only.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K083680: Vitros Chemistry Products K+DT Slides: Vitros Chemistry Products DT Calibrator Kit, Model K+DT Slides: 153 2258.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K083680

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026