510(k) Report

510(k) · Cleared

Recalled · Class II · 2018

Eea Hemorrhoid Stapler & Accessories

K083781510(k) TraditionalCleared Feb 4, 200947-day reviewClass II21 CFR 878.4750Recalls 2

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Surgical Devices, A Global Business Unit Covidien · GDW Staple, Implantable

Cleared on Feb 4, 2009 as substantially equivalent to K062850 (United States Surgical, A Division of Tyco Healthc, 2006) and 1 other predicate after a 47-day review. Its family tree reaches back 2 generations to 2003. 1 of the 4 devices in its family, counting itself, has a Class I recall. It has been recalled 2 times.

Decided
Feb 4, 2009
Review
47 days
Class
Class II
Product code
GDW
Recalls
2
Predicates
2

Its longest line of descent runs back 2 generations to K024275 (2003). 3 ancestors in all. No later device cites it as a predicate yet. 1 of the 4 devices in this family, counting this one, has a Class I recall.

Other ancestors, by year cleared 2005: 1 other ancestor, 1 with a Class I recall1K024275 · Auto Suture Premium Plus Ceea Disposable Stapler · United States Surgical, A Division of Tyco Healthc · 2003K062850 · Autosuture Circular Eea Surgical Staplers · United States Surgical, A Division of Tyco Healthc · 2006200020022004200620082010
  1. Root · 2 generations backK024275 Auto Suture Premium Plus Ceea Disposable StaplerUnited States Surgical, A Division of Tyco Healthc · 2003
  2. 1 generation backK062850 Autosuture Circular Eea Surgical StaplersUnited States Surgical, A Division of Tyco Healthc · 2006
  3. This deviceK083781 Eea Hemorrhoid Stapler & AccessoriesSurgical Devices, A Global Business Unit Covidien · 2009

Class I recalls in this family

View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−2K024275Auto Suture Premium Plus Ceea Disposable StaplerUnited States Surgical, A Division of Tyco Healthc2003—
−1K062850Autosuture Circular Eea Surgical StaplersUnited States Surgical, A Division of Tyco Healthc2006—
0 (this device)K083781Eea Hemorrhoid Stapler & AccessoriesSurgical Devices, A Global Business Unit Covidien2009—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
200511
FIG. 1 — Lineage of K083781, 2003–2009Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

1 device in this family has a Class I recall. A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new GDW device

  1. #1 K253657 Tri-staple 2.0™ Reloads; Endo GIA™ Reloads…score 15.0 · 14 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (2)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K062850Autosuture Circular Eea Surgical Staplers
Summary page 1
…Surgical Stapler with Implantable Staple CLASSIFICATION NAME: Staple, Implantable PREDICATE DEVICE(S): AutosutureTM DST Series TM EEA TMSurgical Stapler (K062850) Ethicon Endo-Surgery Proximate® PPH Hemorrhoidal Circular Stapler and Ac…
United States Surgical, A Division of Tyco Healthc2006—
*K051301Proximate PPH Hemorrhoidal Circular Stapler and Accessories
Summary page 1
…A TMSurgical Stapler (K062850) Ethicon Endo-Surgery Proximate® PPH Hemorrhoidal Circular Stapler and Accessories (K051301) DEVICE DESCRIPTION: The EEATM Hemorrhoid stapler is designed for use as a stapling instrume…
Ethicon Endo-Surgery, Inc.2005Class I

Also cleared against K062850: 7 other devices →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (1 Class I)

Recalls of this device

DateClassRecallRoot causeReason
Apr 9, 2018Class IIZ-1527-2018Nonconforming Material/ComponentThere is a potential for improper welding of the yellow staple guide to the instrument. Use of a device with an improperly welded staple guide may result in improper staple formation potentially leading to bleeding or anastomotic leak.
Apr 9, 2018Class IIZ-1528-2018Nonconforming Material/ComponentThere is a potential for improper welding of the yellow staple guide to the instrument. Use of a device with an improperly welded staple guide may result in improper staple formation potentially leading to bleeding or anastomotic leak.

Relatives with a Class I recall

Class I is FDA’s most serious recall class. A recall in the family tree is context for this device, not evidence about it.

  • K051301Proximate PPH Hemorrhoidal Circular Stapler and AccessoriesEthicon Endo-Surgery, Inc. · 2005 · Direct predicate · ◆ in the 2005 ancestors bar of FIG. 11 Class I recall

What does this lineage say?

  • The line of descent spans 6 years and passes through 2 companies; a new generation was cleared every 3.6 years on median.
  • 1 of the 3 ancestors has a recall of any class; 1 has a Class I recall.
  • 7 other devices also cite its predicate K062850.

How does its category compare?

All GDW devices

GDW Staple, Implantable: FDA decisions, review times, recalls and adverse event reports over 20 years. 2009, this device’s year, is highlighted.

FDA decisions per year · GDW

3in 2025

2007: 82008: 72009: 132010: 102011: 112012: 92013: 132014: 152015: 82016: 112017: 132018: 72019: 122020: 102021: 92022: 72023: 42024: 22025: 32026 (partial year): 3
2007high 15 (2014) · low 2 (2024)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · GDW

111in 2025

2007: 56 days median2008: 57 days median2009: 27 days median2010: 39 days median2011: 49 days median2012: 45 days median2013: 49 days median2014: 63 days median2015: 111 days median2016: 96 days median2017: 103 days median2018: 90 days median2019: 205 days median2020: 88 days median2021: 233 days median2022: 89 days median2023: 267 days median2025: 111 days median2026 (partial year): 141 days median
2007high 267 (2023) · low 27 (2009)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · GDW

3in 2025

2007: 92009: 222010: 22011: 92012: 11, 1 Class I2013: 12015: 62016: 22017: 32018: 32019: 4, 4 Class I2020: 112023: 12025: 3
2007high 22 (2009) · low 0 (2008)2026

Class I (5 since 2007) Class II/III not classified

Adverse event reports per year · GDW

11,905in 2025

2007: 2,4012008: 2,3802009: 4,0142010: 3,7682011: 3,8262012: 3,7172013: 3,7772014: 4,7842015: 4,8992016: 5,1062017: 11,6432018: 14,9142019: 16,6002020: 12,3322021: 13,0152022: 13,6052023: 14,6232024: 13,2802025: 11,905
2007high 16,600 (2019) · low 2,380 (2008)2025

MAUDE reports naming product code GDW, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
200785692,401
200875702,380
20091327224,014
2010103923,768
2011114993,826
201294511 (1)3,717
2013134913,777
2014156304,784
2015811164,899
2016119625,106
201713103311,643
2018790314,914
2019122054 (4)16,600
202010881112,332
20219233013,015
2022789013,605
20234267114,623
20242—013,280
20253111311,905
202631410—

What is it indicated for?

The EEATM Hemorrhoid Stapler and accessories has application throughout the anal canal to perform surgical treatment of hemorrhoidal disease.

The EEATM Hemorrhoid Stapler and accessories can also be used in the lower alimentary tract for the creation of end-to-end and end-to-side anastomosis.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K083781: Eea Hemorrhoid Stapler & Accessories.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K083781

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026